메뉴 건너뛰기




Volumn 219, Issue 6, 2005, Pages 415-424

A three-dimensional dynamic finite element model of the prosthetic knee joint: Simulation of joint laxity and kinematics

Author keywords

Finite element model; Ligaments; Total knee arthroplasty (TKA)

Indexed keywords

BOUNDARY CONDITIONS; COMPUTER SIMULATION; FINITE ELEMENT METHOD; IMPLANTS (SURGICAL); LIGAMENTS; MATHEMATICAL MODELS; OPTIMIZATION; ARTHROPLASTY; JOINT PROSTHESES; JOINTS (ANATOMY); KINEMATICS; KNEE PROSTHESES; ORTHOPEDICS; PHYSIOLOGICAL MODELS; PROSTHETICS;

EID: 27744560275     PISSN: 09544119     EISSN: 09544119     Source Type: Journal    
DOI: 10.1243/095441105X34437     Document Type: Article
Times cited : (17)

References (26)
  • 1
    • 0242664747 scopus 로고    scopus 로고
    • Impact of patellofemoral design on patellofemoral forces and polyethylene stresses
    • D'Lima, D. D., Chen, P. C., Kester, M. A., and Colwell, C. W. Jr. Impact of patellofemoral design on patellofemoral forces and polyethylene stresses. J. Bone Jt Surg. Am., 2003, 85A, Suppl. 4, 85-93.
    • (2003) J. Bone Jt. Surg. Am. , vol.85 A , Issue.SUPPL. 4 , pp. 85-93
    • D'Lima, D.D.1    Chen, P.C.2    Kester, M.A.3    Colwell Jr., C.W.4
  • 2
    • 2542422783 scopus 로고    scopus 로고
    • A new method to investigate in vivo knee behavior using a finite element model of the lower limb
    • Beillas, P., Papaioannou, G., Tashman, S., and Yang, K. H. A new method to investigate in vivo knee behavior using a finite element model of the lower limb. J. Biomechanics, 2004, 37(7), 1019-1030.
    • (2004) J. Biomechanics , vol.37 , Issue.7 , pp. 1019-1030
    • Beillas, P.1    Papaioannou, G.2    Tashman, S.3    Yang, K.H.4
  • 3
    • 10444255467 scopus 로고    scopus 로고
    • Explicit finite element modeling of total knee replacement mechanics
    • Halloran, J. P., Petrella, A. J., and Rullkoetter, P.J. Explicit finite element modeling of total knee replacement mechanics. J Biomechanics, 2005, 38(2), 323-331.
    • (2005) J. Biomechanics , vol.38 , Issue.2 , pp. 323-331
    • Halloran, J.P.1    Petrella, A.J.2    Rullkoetter, P.J.3
  • 4
    • 27744561981 scopus 로고    scopus 로고
    • Bel Repository Instituti Rizzoli, Italy
    • http://www.tecno.ior.it/VRLAB/researchers/Repository/BEL_repository.html, Bel Repository Instituti Rizzoli, Italy, 2005.
    • (2005)
  • 5
    • 0003742997 scopus 로고
    • A constitutive model and finite element representation for transversely isotropic soft tissues
    • The University of Utah, USA
    • Weiss, J. A. A constitutive model and finite element representation for transversely isotropic soft tissues, The University of Utah, USA, 1994.
    • (1994)
    • Weiss, J.A.1
  • 6
    • 0013560946 scopus 로고
    • Human knee ligaments: Structure, function and mechanical properties
    • Thesis, University of Nijmegen, Nijmegen, The Netherlands
    • Mommersteeg, T. J. A. Human knee ligaments: structure, function and mechanical properties. Thesis, University of Nijmegen, Nijmegen, The Netherlands, 1994.
    • (1994)
    • Mommersteeg, T.J.A.1
  • 7
    • 0022640049 scopus 로고
    • Comparison of material properties in fascicle-bone units from human patellar tendon and knee ligaments
    • Butler, D. L., Kay, M. D., and Stouffer, D. C. Comparison of material properties in fascicle-bone units from human patellar tendon and knee ligaments. J. Biomechanics, 1986, 19(6), 425-432.
    • (1986) J. Biomechanics , vol.19 , Issue.6 , pp. 425-432
    • Butler, D.L.1    Kay, M.D.2    Stouffer, D.C.3
  • 8
    • 0028054802 scopus 로고
    • The mechanical properties of the two bundles of the human posterior cruciate ligament
    • Race, A. and Amis, A. A. The mechanical properties of the two bundles of the human posterior cruciate ligament. J. Biomechanics, 1994, 27(1), 13-24.
    • (1994) J. Biomechanics , vol.27 , Issue.1 , pp. 13-24
    • Race, A.1    Amis, A.A.2
  • 9
    • 0032431481 scopus 로고    scopus 로고
    • Material characterization of human medial collateral ligament
    • Quapp, K. M. and Weiss, J. A. Material characterization of human medial collateral ligament. J. Biomech. Engng, 1998, 120(6), 757-763.
    • (1998) J. Biomech. Engng. , vol.120 , Issue.6 , pp. 757-763
    • Quapp, K.M.1    Weiss, J.A.2
  • 10
    • 0003933918 scopus 로고
    • Passive motion characteristics of the human knee joint; experiments and computer simulations
    • Thesis, University of Nijmegen, Nijmegen, The Netherlands
    • Blankevoort, L. Passive motion characteristics of the human knee joint; experiments and computer simulations. Thesis, University of Nijmegen, Nijmegen, The Netherlands, 1991.
    • (1991)
    • Blankevoort, L.1
  • 11
    • 0025426762 scopus 로고
    • The three-dimensional tracking pattern of the human patella
    • van Kampen, A. and Huiskes, R. The three-dimensional tracking pattern of the human patella. J. Orthop. Res., 1990, 8(3), 372-382.
    • (1990) J. Orthop. Res. , vol.8 , Issue.3 , pp. 372-382
    • van Kampen, A.1    Huiskes, R.2
  • 12
    • 0018526117 scopus 로고
    • Biomechanics of the patellofemoral joint
    • Hungerford, D. S. and Barry, M. Biomechanics of the patellofemoral joint. Clin. Orthop., 1979, 144, 9-15.
    • (1979) Clin. Orthop. , vol.144 , pp. 9-15
    • Hungerford, D.S.1    Barry, M.2
  • 13
    • 0036141338 scopus 로고    scopus 로고
    • Varus and valgus flexion laxity of total knee alignment methods in loaded cadaveric knees
    • Romero, J., Duronio, J. F., Sohrabi, A., Alexander, N., MacWilliams, B. A., Jones, L. C. et al. Varus and valgus flexion laxity of total knee alignment methods in loaded cadaveric knees. Clin. Orthop., 2002, 394, 243-253.
    • (2002) Clin. Orthop. , vol.394 , pp. 243-253
    • Romero, J.1    Duronio, J.F.2    Sohrabi, A.3    Alexander, N.4    MacWilliams, B.A.5    Jones, L.C.6
  • 14
    • 0019785993 scopus 로고
    • Ligamentous and capsular restraints preventing straight medial and lateral laxity in intact human cadaver knees
    • Grood, E. S., Noyes, F. R., Butler, D. L., and Suntay, W. J. Ligamentous and capsular restraints preventing straight medial and lateral laxity in intact human cadaver knees. J. Bone Jt Surg. Am., 1981, 63(8), 1257-1269.
    • (1981) J. Bone Jt. Surg. Am. , vol.63 , Issue.8 , pp. 1257-1269
    • Grood, E.S.1    Noyes, F.R.2    Butler, D.L.3    Suntay, W.J.4
  • 15
    • 0041668191 scopus 로고    scopus 로고
    • Ihe meniscofemoral ligaments: Secondary restraints to the posterior drawer. Analysis of antero-posterior and rotary laxity in the intact and posterior-cruciate-deficient knee
    • Gupte, C. M., Bull, A. M., Thomas, R. D., and Amis, A. A. Ihe meniscofemoral ligaments: secondary restraints to the posterior drawer. Analysis of antero-posterior and rotary laxity in the intact and posterior-cruciate-deficient knee. J. Bone Jt Surg. Br., 2003, 85(5), 765-773.
    • (2003) J. Bone Jt. Surg. Br. , vol.85 , Issue.5 , pp. 765-773
    • Gupte, C.M.1    Bull, A.M.2    Thomas, R.D.3    Amis, A.A.4
  • 16
    • 0018862729 scopus 로고
    • Ligamentous restraints to anterior-posterior drawer in the human knee. A biomechanical study
    • Butler, D. L, Noyes, F. R., and Grood, E. S. Ligamentous restraints to anterior-posterior drawer in the human knee. A biomechanical study. J. Bone Jt Surg. Am., 1980, 62(2), 259-270.
    • (1980) J. Bone Jt. Surg. Am. , vol.62 , Issue.2 , pp. 259-270
    • Butler, D.L.1    Noyes, F.R.2    Grood, E.S.3
  • 17
    • 0023274307 scopus 로고
    • Varus-valgus and rotational stability in rotationally unconstrained total knee arthroplasty
    • Whiteside, L. A., Kasselt, M. R., and Haynes, D. W. Varus-valgus and rotational stability in rotationally unconstrained total knee arthroplasty. Clin. Orthop., 1987, 219, 147-157.
    • (1987) Clin. Orthop. , vol.219 , pp. 147-157
    • Whiteside, L.A.1    Kasselt, M.R.2    Haynes, D.W.3
  • 19
    • 0025054164 scopus 로고
    • The effect of femoral component position on patellar tracking after total knee arthroplasty
    • Rhoads, D. D., Noble, P. C., Reuben, J. D., Mahoney, O. M., and Tullos, H. S. The effect of femoral component position on patellar tracking after total knee arthroplasty. Clin. Orthop., 1990, 260, 43-51.
    • (1990) Clin. Orthop. , vol.260 , pp. 43-51
    • Rhoads, D.D.1    Noble, P.C.2    Reuben, J.D.3    Mahoney, O.M.4    Tullos, H.S.5
  • 20
    • 0034926225 scopus 로고    scopus 로고
    • The effect of component placement on knee kinetics after arthroplasty with an unconstrained prosthesis
    • Miller, M. C., Zhang, A. X., Petrella, A. J., Berger, R. A., and Rubash, H. E. The effect of component placement on knee kinetics after arthroplasty with an unconstrained prosthesis. J. Orthop. Res., 2001, 19(4), 614-620.
    • (2001) J. Orthop. Res. , vol.19 , Issue.4 , pp. 614-620
    • Miller, M.C.1    Zhang, A.X.2    Petrella, A.J.3    Berger, R.A.4    Rubash, H.E.5
  • 21
    • 0038755507 scopus 로고    scopus 로고
    • Measurement of patellar tracking: Assessment and analysis of the literature
    • Katchburian, M. V., Bull, A. M., Shih, Y. F., Heatley, F. W., and Amis, A. A. Measurement of patellar tracking: assessment and analysis of the literature. Clin. Orthop., 2003, 412, 241-259.
    • (2003) Clin. Orthop. , vol.412 , pp. 241-259
    • Katchburian, M.V.1    Bull, A.M.2    Shih, Y.F.3    Heatley, F.W.4    Amis, A.A.5
  • 22
    • 0031468408 scopus 로고    scopus 로고
    • Differences in patellar tracking and knee kinematics among three different total knee designs
    • Chew, J. T., Stewart, N. J., Hanssen, A. D., Luo, Z. P., Rand, J. A., and An, K. N. Differences in patellar tracking and knee kinematics among three different total knee designs. Clin. Orthop., 1997, 345, 87-98.
    • (1997) Clin. Orthop. , vol.345 , pp. 87-98
    • Chew, J.T.1    Stewart, N.J.2    Hanssen, A.D.3    Luo, Z.P.4    Rand, J.A.5    An, K.N.6
  • 23
    • 0037591624 scopus 로고    scopus 로고
    • Patellar position after total knee arthroplasty: Influence of femoral component malposition
    • Armstrong, A. D., Brien, H. J., Dunning, C. E., King, G. J., Johnson, J. A., and Chess, D. G. Patellar position after total knee arthroplasty: Influence of femoral component malposition. J. Arthroplasty, 2003, 18(4), 458-465.
    • (2003) J. Arthroplasty , vol.18 , Issue.4 , pp. 458-465
    • Armstrong, A.D.1    Brien, H.J.2    Dunning, C.E.3    King, G.J.4    Johnson, J.A.5    Chess, D.G.6
  • 24
    • 0342804263 scopus 로고    scopus 로고
    • In vivo kinematics of total knee arthroplasty; concave versus posterior-stabilised tibial joint surface
    • Uvehammer, J., Karrholm, J., and Brandsson, S. In vivo kinematics of total knee arthroplasty; concave versus posterior-stabilised tibial joint surface. J. Bone Jt Surg. Br, 2000, 82, 499-505,
    • (2000) J. Bone Jt. Surg. Br. , vol.82 , pp. 499-505
    • Uvehammer, J.1    Karrholm, J.2    Brandsson, S.3
  • 25
    • 0033750997 scopus 로고    scopus 로고
    • Comparison between the kinematics of fixed and rotating bearing knee prostheses
    • D'Lima, D. D., Trice, M., Urquhart, A. G., and Colwell, C. W. Jr. Comparison between the kinematics of fixed and rotating bearing knee prostheses. Clin. Orthop., 2000, 380, 151-157.
    • (2000) Clin. Orthop. , vol.380 , pp. 151-157
    • D'Lima, D.D.1    Trice, M.2    Urquhart, A.G.3    Colwell Jr., C.W.4
  • 26
    • 4444258486 scopus 로고    scopus 로고
    • Implant design affects knee arthroplasty kinematics during stair-stepping
    • Banks, S. A. and Hodge, W. A. Implant design affects knee arthroplasty kinematics during stair-stepping. Clin. Orthop. Related Res., 2004, 426, 187-193.
    • (2004) Clin. Orthop. Related Res. , vol.426 , pp. 187-193
    • Banks, S.A.1    Hodge, W.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.