메뉴 건너뛰기




Volumn 4, Issue , 2005, Pages

The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups - Finite element simulations and experimental tests

Author keywords

[No Author keywords available]

Indexed keywords

ABDUCTION ANGLE; TOTAL HIP REPLACEMENT; UHMWPE ACETABULAR CUPS;

EID: 27744534971     PISSN: 1475925X     EISSN: 1475925X     Source Type: Journal    
DOI: 10.1186/1475-925X-4-32     Document Type: Article
Times cited : (49)

References (31)
  • 2
    • 0028197478 scopus 로고
    • Severe polyethylene wear in total hip arthroplasty. Observations from retrieved AML PLUS hip implants with an ACS polyethylene liner
    • Bono JV, Sanford L, Toussaint JT: Severe polyethylene wear in total hip arthroplasty. Observations from retrieved AML PLUS hip implants with an ACS polyethylene liner. J Arthroplasty 1994, 9:119-125.
    • (1994) J. Arthroplasty , vol.9 , pp. 119-125
    • Bono, J.V.1    Sanford, L.2    Toussaint, J.T.3
  • 3
    • 0029838003 scopus 로고    scopus 로고
    • Relationship between polyethylene wear, pelvic osteolysis, and clinical symptomatology in patients with cementless acetabular components. A framework for decision making
    • Hozack WJ, Mesa JJ, Carey C, Rothman RH: Relationship between polyethylene wear, pelvic osteolysis, and clinical symptomatology in patients with cementless acetabular components. A framework for decision making. J Arthroplasty 1996, 11:769-772.
    • (1996) J. Arthroplasty , vol.11 , pp. 769-772
    • Hozack, W.J.1    Mesa, J.J.2    Carey, C.3    Rothman, R.H.4
  • 4
    • 0031036192 scopus 로고    scopus 로고
    • Prospective study of 100 consecutive Harris-Galante porous total hip arthroplasties. 4- to 8-year follow-up study
    • Petersilge WJ, D'Lima DD, Walker RH, Colwell CWJ: Prospective study of 100 consecutive Harris-Galante porous total hip arthroplasties. 4- to 8-year follow-up study. J Arthroplasty 1997, 12:185-193.
    • (1997) J. Arthroplasty , vol.12 , pp. 185-193
    • Petersilge, W.J.1    D'Lima, D.D.2    Walker, R.H.3    Colwell, C.W.J.4
  • 5
    • 0030198688 scopus 로고    scopus 로고
    • Adaptive finite element modeling of long-term polyethylene wear in total hip arthroplasty
    • Maxian TA, Brown TD, Pedersen DR, Callaghan JJ: Adaptive finite element modeling of long-term polyethylene wear in total hip arthroplasty. J Orthop Res 1996, 14:668-675.
    • (1996) J. Orthop. Res. , vol.14 , pp. 668-675
    • Maxian, T.A.1    Brown, T.D.2    Pedersen, D.R.3    Callaghan, J.J.4
  • 6
    • 0018537364 scopus 로고
    • Contact pressure dependence of wear rates of ultra high molecular weight polyethylene
    • Rostoker W, Galante JO: Contact pressure dependence of wear rates of ultra high molecular weight polyethylene. J Biomed Mater Res 1979, 13:957-964.
    • (1979) J. Biomed. Mater. Res. , vol.13 , pp. 957-964
    • Rostoker, W.1    Galante, J.O.2
  • 7
    • 0035175939 scopus 로고    scopus 로고
    • Optimizing acetabular component position to minimize impingement and reduce contact stress
    • Pt. 2
    • D'Lima DD, Chen PC, Colwell CWJ: Optimizing acetabular component position to minimize impingement and reduce contact stress. J Bone Joint Surg Am 2001, 83-A Suppl 2 Pt 2:87-91.
    • (2001) J. Bone Joint Surg. Am. , vol.83 A , Issue.SUPPL. 2 , pp. 87-91
    • D'Lima, D.D.1    Chen, P.C.2    Colwell, C.W.J.3
  • 9
    • 0032610912 scopus 로고    scopus 로고
    • An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements
    • Jin ZM, Heng SM, Ng HW, Auger DD: An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements. Proc Inst Mech Eng [H] 1999, 213:317-327.
    • (1999) Proc. Inst. Mech. Eng. [H] , vol.213 , pp. 317-327
    • Jin, Z.M.1    Heng, S.M.2    Ng, H.W.3    Auger, D.D.4
  • 10
    • 0035228123 scopus 로고    scopus 로고
    • Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components
    • Raimondi MT, Santambrogio C, Pietrabissa R, Raffelini F, Molfetta L: Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components. Proc Inst Mech Eng [H] 2001, 215:377-391.
    • (2001) Proc. Inst. Mech. Eng. [H] , vol.215 , pp. 377-391
    • Raimondi, M.T.1    Santambrogio, C.2    Pietrabissa, R.3    Raffelini, F.4    Molfetta, L.5
  • 11
    • 1942424241 scopus 로고    scopus 로고
    • Long-term results of rotational total hip arthroplasty: Radiological analysis
    • Akasaki K: Long-term results of rotational total hip arthroplasty: radiological analysis. J Orthop Sci 2004, 9:126-134.
    • (2004) J. Orthop. Sci. , vol.9 , pp. 126-134
    • Akasaki, K.1
  • 12
    • 0028500036 scopus 로고
    • A parametric analysis of the contact stress in ultra-high molecular weight polyethylene acetabular cups
    • Jin ZM, Dowson D, Fisher J: A parametric analysis of the contact stress in ultra-high molecular weight polyethylene acetabular cups. Med Eng Phys 1994, 16:398-405.
    • (1994) Med. Eng. Phys. , vol.16 , pp. 398-405
    • Jin, Z.M.1    Dowson, D.2    Fisher, J.3
  • 14
    • 0029616092 scopus 로고
    • Wear of the polyethylene acetabular cup. The effect of head material, head diameter, and cup thickness studied with a hip simulator
    • Saikko VO: Wear of the polyethylene acetabular cup. The effect of head material, head diameter, and cup thickness studied with a hip simulator. Acta Orthop Scand 1995, 66:501-506.
    • (1995) Acta Orthop. Scand. , vol.66 , pp. 501-506
    • Saikko, V.O.1
  • 15
    • 0036169065 scopus 로고    scopus 로고
    • An elasto-plastic finite element model for polyethylene wear in total hip arthroplasty
    • Teoh SH, Chan WH, Thampuran R: An elasto-plastic finite element model for polyethylene wear in total hip arthroplasty. J Biomech 2002, 35:323-330.
    • (2002) J. Biomech. , vol.35 , pp. 323-330
    • Teoh, S.H.1    Chan, W.H.2    Thampuran, R.3
  • 16
    • 0027715365 scopus 로고
    • Failed innovation in total hip replacement. Diagnosis and proposals for a cure
    • Huiskes R: Failed innovation in total hip replacement. Diagnosis and proposals for a cure. Acta Orthop Scand 1993, 64:699-716.
    • (1993) Acta Orthop. Scand. , vol.64 , pp. 699-716
    • Huiskes, R.1
  • 19
    • 0004249455 scopus 로고    scopus 로고
    • Finnish Arthoplasty Register. Helsinki, Finland, National Agency for Medicines
    • Finnish Arthoplasty Register. The 2000-2001 implant yearbook on orthopaedic endoprostheses. Helsinki, Finland, National Agency for Medicines; 2003.
    • (2003) The 2000-2001 Implant Yearbook on Orthopaedic Endoprostheses
  • 27
    • 0642314332 scopus 로고    scopus 로고
    • Analysis of contact mechanics in McKee-Farrar metal-on-metal hip implants
    • Yew A, Jagatia M, Ensaff H, Jin ZM: Analysis of contact mechanics in McKee-Farrar metal-on-metal hip implants. Proc Inst Mech Eng [H] 2003, 217:333-340.
    • (2003) Proc. Inst. Mech. Eng. [H] , vol.217 , pp. 333-340
    • Yew, A.1    Jagatia, M.2    Ensaff, H.3    Jin, Z.M.4
  • 28
    • 4043133785 scopus 로고    scopus 로고
    • Implementing capsule representation in a total hip dislocation finite element model
    • Stewart KJ, Pedersen DR, Callaghan JJ, Brown TD: Implementing capsule representation in a total hip dislocation finite element model. Iowa Orthop J 2004, 24:1-8.
    • (2004) Iowa Orthop. J. , vol.24 , pp. 1-8
    • Stewart, K.J.1    Pedersen, D.R.2    Callaghan, J.J.3    Brown, T.D.4
  • 30
    • 0033922311 scopus 로고    scopus 로고
    • Wear of high-dose gamma-irradiated polyethylene in total hip replacements
    • Oonishi H, Kadoya Y: Wear of high-dose gamma-irradiated polyethylene in total hip replacements. J Orthop Sci 2000, 5:223-228.
    • (2000) J. Orthop. Sci. , vol.5 , pp. 223-228
    • Oonishi, H.1    Kadoya, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.