메뉴 건너뛰기




Volumn 12, Issue 2, 1997, Pages 185-193

Prospective study of 100 consecutive Harris-Galante porous total hip arthroplasties: 4- to 8-year follow-up study

Author keywords

clinical outcome radiographic outcome; femoral prosthesis; follow up study; porous; total hip arthroplasty

Indexed keywords

ADULT; AGED; ARTICLE; BONE NECROSIS; COXITIS; FEMALE; FOLLOW UP; HIP DISEASE; HUMAN; MAJOR CLINICAL STUDY; MALE; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PAIN; PROSPECTIVE STUDY; PROSTHESIS LOOSENING; RHEUMATOID ARTHRITIS; SURVIVAL; TOTAL HIP PROSTHESIS; TREATMENT OUTCOME;

EID: 0031036192     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(97)90065-6     Document Type: Article
Times cited : (32)

References (36)
  • 1
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislo-cation and acetabular fractures: Treatment by mold arthroplasty: an end-result study using a new method of result evaluation
    • Harris WH: Traumatic arthritis of the hip after dislo-cation and acetabular fractures: treatment by mold arthroplasty: an end-result study using a new method of result evaluation. J Bone Joint Surg 51A:737, 1969
    • (1969) J Bone Joint Surg , vol.51 A , pp. 737
    • Harris, W.H.1
  • 2
    • 0025179416 scopus 로고
    • Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components
    • Engh CA, Massin P, Suthers KE: Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop 257:107, 1990
    • (1990) Clin Orthop , vol.257 , pp. 107
    • Engh, C.A.1    Massin, P.2    Suthers, K.E.3
  • 3
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components
    • Gruen TA, McNeice GM, Amstutz HC: "Modes of failure" of cemented stem-type femoral components. Clin Orthop 141:17, 1979
    • (1979) Clin Orthop , vol.141 , pp. 17
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 5
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J, Ilstrup D, Morrey B: Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg 72A:518, 1990
    • (1990) J Bone Joint Surg , vol.72 A , pp. 518
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 6
    • 0026475736 scopus 로고
    • Cementless total hip arthroplasty using a porous-coated prosthesis for bone ingrowth fixation
    • Woolson ST, Maloney WJ: Cementless total hip arthroplasty using a porous-coated prosthesis for bone ingrowth fixation. J Arthroplasty 7 (suppl):381, 1992
    • (1992) J Arthroplasty , vol.7 , Issue.SUPPL. , pp. 381
    • Woolson, S.T.1    Maloney, W.J.2
  • 7
    • 12644299480 scopus 로고
    • Results of cementless HGP prosthesis
    • Galante JO: Results of cementless HGP prosthesis. Orthop Trans 12: 265, 1988
    • (1988) Orthop Trans , vol.12 , pp. 265
    • Galante, J.O.1
  • 8
    • 0027058226 scopus 로고
    • A prospective study of 100 consecutive Harris-Galante Porous total hip arthroplasties
    • Lachiewicz PF, Anspach WE, DeMasi R: A prospective study of 100 consecutive Harris-Galante Porous total hip arthroplasties. J Arthroplasty 7:519, 1992
    • (1992) J Arthroplasty , vol.7 , pp. 519
    • Lachiewicz, P.F.1    Anspach, W.E.2    DeMasi, R.3
  • 9
    • 0026515578 scopus 로고
    • Results of the Harris-Galante cementless hip prosthesis
    • Kim YH, Kim VE: Results of the Harris-Galante cementless hip prosthesis. J Bone Joint Surg 74B:83, 1992
    • (1992) J Bone Joint Surg , vol.74 B , pp. 83
    • Kim, Y.H.1    Kim, V.E.2
  • 10
    • 0027161508 scopus 로고
    • Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement
    • Martell JM, Pierson RH, Jacobs JJ et al: Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement. J Bone Joint Surg 75A:554, 1993
    • (1993) J Bone Joint Surg , vol.75 A , pp. 554
    • Martell, J.M.1    Pierson, R.H.2    Jacobs, J.J.3
  • 11
    • 0025059507 scopus 로고
    • Comparison of a hybrid with an uncemented total hip replacement
    • Maloney WJ, Harris WH: Comparison of a hybrid with an uncemented total hip replacement. J Bone Joint Surg 72A: 1349, 1990
    • (1990) J Bone Joint Surg , vol.72 A , pp. 1349
    • Maloney, W.J.1    Harris, W.H.2
  • 12
    • 0027655696 scopus 로고
    • Two- to five-year follow-up of Harris-Galante cementless total hip arthroplasty
    • Tong K-M, Hsu K-C, Ku M-C, Lee T-S: Two- to five-year follow-up of Harris-Galante cementless total hip arthroplasty. Chin Med J 52:137, 1993
    • (1993) Chin Med J , vol.52 , pp. 137
    • Tong, K.-M.1    Hsu, K.-C.2    Ku, M.-C.3    Lee, T.-S.4
  • 13
    • 5544315889 scopus 로고
    • Primary total hip reconstruction with a cementless titanium fiber-coated prosthesis
    • Pierson RH, Jacobs JJ, Sheinkop MB et al: Primary total hip reconstruction with a cementless titanium fiber-coated prosthesis. Orthop Trans 13:578, 1989
    • (1989) Orthop Trans , vol.13 , pp. 578
    • Pierson, R.H.1    Jacobs, J.J.2    Sheinkop, M.B.3
  • 14
    • 0028857458 scopus 로고
    • Early aseptic loosening of uncemented femoral components in primary total hip replacement
    • Havelin LI, Espehaug B, Vollset SE, Engesaeter LB: Early aseptic loosening of uncemented femoral components in primary total hip replacement. J Bone Joint Surg 77B: 11, 1995
    • (1995) J Bone Joint Surg , vol.77 B , pp. 11
    • Havelin, L.I.1    Espehaug, B.2    Vollset, S.E.3    Engesaeter, L.B.4
  • 15
    • 0024444821 scopus 로고
    • Cementless total hip arthroplasty: Femoral remodeling and clinical experience
    • Rosenberg A: Cementless total hip arthroplasty: femoral remodeling and clinical experience. Orthopedics 12:1223, 1989
    • (1989) Orthopedics , vol.12 , pp. 1223
    • Rosenberg, A.1
  • 18
    • 0026753593 scopus 로고
    • Thigh pain despite bone ingrowth into uncemented femoral stems
    • Barrack RL, Jasty M, Bragdon C et al: Thigh pain despite bone ingrowth into uncemented femoral stems. J Bone Joint Surg 74B:507, 1992
    • (1992) J Bone Joint Surg , vol.74 B , pp. 507
    • Barrack, R.L.1    Jasty, M.2    Bragdon, C.3
  • 19
    • 0026771982 scopus 로고
    • Failure of cementless fixation of the femoral component in total hip arthroplasty
    • Otani T, Whiteside L: Failure of cementless fixation of the femoral component in total hip arthroplasty. Orthop Clin North Am 23:335, 1992
    • (1992) Orthop Clin North Am , vol.23 , pp. 335
    • Otani, T.1    Whiteside, L.2
  • 20
    • 0024430093 scopus 로고
    • The effect of stem fit on bone hypertrophy and pain relief in cementless total hip arthroplasty
    • Whiteside LA: The effect of stem fit on bone hypertrophy and pain relief in cementless total hip arthroplasty. Clin Orthop 247:138, 1989
    • (1989) Clin Orthop , vol.247 , pp. 138
    • Whiteside, L.A.1
  • 21
    • 0023780762 scopus 로고
    • Quantitative analysis of tissue growth into human porous total hip components
    • Cook SD, Barrack RL, Thomas KA, Haddad RJ: Quantitative analysis of tissue growth into human porous total hip components. J Arthroplasty 3:249, 1988
    • (1988) J Arthroplasty , vol.3 , pp. 249
    • Cook, S.D.1    Barrack, R.L.2    Thomas, K.A.3    Haddad, R.J.4
  • 22
    • 0027397479 scopus 로고
    • The porous-coated anatomic total hip prothesis, inserted without cement
    • Heekin RD, Callaghan JJ, Hopkinson WJ et al: The porous-coated anatomic total hip prothesis, inserted without cement. J Bone Joint Surg 74A:77, 1993
    • (1993) J Bone Joint Surg , vol.74 A , pp. 77
    • Heekin, R.D.1    Callaghan, J.J.2    Hopkinson, W.J.3
  • 23
    • 0023712327 scopus 로고
    • Macroscopic and microscopic evidence of prosthetic fixation with porous-coated materials
    • Collier JP, Mayor MB, Chae JC et al: Macroscopic and microscopic evidence of prosthetic fixation with porous-coated materials. Clin Orthop 235:173, 1988
    • (1988) Clin Orthop , vol.235 , pp. 173
    • Collier, J.P.1    Mayor, M.B.2    Chae, J.C.3
  • 24
    • 0026013764 scopus 로고
    • Micromotion of cemented and uncemented femoral components
    • Burke DW, O'Connor DO, Zalenski EG et al: Micromotion of cemented and uncemented femoral components. J Bone Joint Surg 73B:33, 1991
    • (1991) J Bone Joint Surg , vol.73 B , pp. 33
    • Burke, D.W.1    O'Connor, D.O.2    Zalenski, E.G.3
  • 25
    • 0028021479 scopus 로고
    • The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements
    • Goetz DD, Smith EJ, Harris WH: The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements. J Bone Joint Surg 76A:1121, 1994
    • (1994) J Bone Joint Surg , vol.76 A , pp. 1121
    • Goetz, D.D.1    Smith, E.J.2    Harris, W.H.3
  • 26
    • 0026718908 scopus 로고
    • The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement
    • Tanzer M, Maloney WJ, Jasty M, Harris WH: The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement. J Bone Joint Surg 74A:404, 1992
    • (1992) J Bone Joint Surg , vol.74 A , pp. 404
    • Tanzer, M.1    Maloney, W.J.2    Jasty, M.3    Harris, W.H.4
  • 27
    • 0041459101 scopus 로고
    • Roengenographic evaluation of the AML porouscoated acetabular component: A six-year minimum follow-up study
    • Beauchesne RP, Kukita Y, Knezevich S, Kathleen S: Roengenographic evaluation of the AML porouscoated acetabular component: a six-year minimum follow-up study. Orthop Trans 16:749, 1993
    • (1993) Orthop Trans , vol.16 , pp. 749
    • Beauchesne, R.P.1    Kukita, Y.2    Knezevich, S.3    Kathleen, S.4
  • 29
    • 0008879068 scopus 로고
    • Endosteal osteolysis in uncemented porous-coated femoral components
    • Kim Y-H, Kim VEM, Oh J-H: Endosteal osteolysis in uncemented porous-coated femoral components. Orthop Trans 16:744, 1993
    • (1993) Orthop Trans , vol.16 , pp. 744
    • Kim, Y.-H.1    Vem, K.2    Oh, J.-H.3
  • 30
    • 0028364104 scopus 로고
    • Cementless porous-coated anatomic medullary locking total hip prostheses
    • Kim Y-H, Kim VEM: Cementless porous-coated anatomic medullary locking total hip prostheses. J Arthroplasty 9:243, 1994
    • (1994) J Arthroplasty , vol.9 , pp. 243
    • Kim, Y.-H.1    Kim, V.E.M.2
  • 31
    • 0027416061 scopus 로고
    • Uncemented porous-coated anatomic total hip replacement: Results at six years in a consecutive series
    • Kim Y-H, Kim VEM: Uncemented porous-coated anatomic total hip replacement: results at six years in a consecutive series. J Bone Joint Surg 75B:6, 1993
    • (1993) J Bone Joint Surg , vol.75 B , pp. 6
    • Kim, Y.-H.1    Kim, V.E.M.2
  • 33
    • 0025679122 scopus 로고
    • Histologic, biochemical, and ion analysis of tissue and fluids retrieved during hip arthroplasty
    • Dorr LD, Bloebaum R, Emmanual J, Meldrum R: Histologic, biochemical, and ion analysis of tissue and fluids retrieved during hip arthroplasty. Clin Orthop 261:82, 1990
    • (1990) Clin Orthop , vol.261 , pp. 82
    • Dorr, L.D.1    Bloebaum, R.2    Emmanual, J.3    Meldrum, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.