메뉴 건너뛰기




Volumn 2, Issue 11, 2005, Pages 1203-1210

Automatic measurement of atrial pacing thresholds in dual-chamber pacemakers: Clinical experience with atrial capture management

Author keywords

Atrial capture management; Atrial chamber reset; Atrial threshold test; Atrioventricular conduction; Automatic atrial threshold measurement; Dual chamber pacemaker

Indexed keywords

ACCURACY; ALGORITHM; ARTICLE; ARTIFICIAL HEART PACEMAKER; AUTOMATION; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FOLLOW UP; HEART ATRIUM; HEART ATRIUM ARRHYTHMIA; HEART ATRIUM PACEMAKER; HEART ATRIUM PACING; HEART PROARRHYTHMIA; HUMAN; MAJOR CLINICAL STUDY; MEASUREMENT; MULTICENTER STUDY; PRIORITY JOURNAL; RELIABILITY; SAFETY; TREATMENT INDICATION;

EID: 27744529238     PISSN: 15475271     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrthm.2005.07.023     Document Type: Article
Times cited : (34)

References (24)
  • 1
    • 0033981698 scopus 로고    scopus 로고
    • Automated pacemaker function
    • Wood M. Automated pacemaker function. Cardiol Clin 2000;18:177-191
    • (2000) Cardiol. Clin. , vol.18 , pp. 177-191
    • Wood, M.1
  • 4
    • 0008039679 scopus 로고    scopus 로고
    • Cost-effective follow-up of the patient with a permanent pacemaker
    • Kusumoto FM, Goldschlager N. Cost-effective follow-up of the patient with a permanent pacemaker. Card Electrophysiol Rev 1999;3:60-65
    • (1999) Card. Electrophysiol. Rev. , vol.3 , pp. 60-65
    • Kusumoto, F.M.1    Goldschlager, N.2
  • 7
  • 8
    • 0003705927 scopus 로고
    • Der Schwellwertschrittmacher: Ein neuartiges Prinzip der elektrischen Myokard-Stimulation
    • Dissertation, University of Bonn, Germany
    • Funke HD. Der Schwellwertschrittmacher: Ein neuartiges Prinzip der elektrischen Myokard-Stimulation. Dissertation, University of Bonn, Germany, 1972
    • (1972)
    • Funke, H.D.1
  • 9
    • 27744459573 scopus 로고    scopus 로고
    • Ventricular pacing thresholds variations in DDD pacemaker implanted patients: Capture management feature efficacy
    • (abstr) International Symposium on Progress in Clinical Pacing, Rome, Italy, December
    • Cornacchia D, Argnani S, Saccomanno G, Marini M, Tampieri E, Grovale N, Corte T, Marotta T. Ventricular pacing thresholds variations in DDD pacemaker implanted patients: Capture management feature efficacy (abstr). International Symposium on Progress in Clinical Pacing, Rome, Italy, December 2002
    • (2002)
    • Cornacchia, D.1    Argnani, S.2    Saccomanno, G.3    Marini, M.4    Tampieri, E.5    Grovale, N.6    Corte, T.7    Marotta, T.8
  • 10
    • 0030844607 scopus 로고    scopus 로고
    • Diagnostic value of auto-capture: Detection of lead dislocation
    • Liebold A, Birnbaum DE. Diagnostic value of auto-capture: Detection of lead dislocation. Z Kardiol 1997;86:521-523
    • (1997) Z. Kardiol. , vol.86 , pp. 521-523
    • Liebold, A.1    Birnbaum, D.E.2
  • 11
    • 27744532898 scopus 로고    scopus 로고
    • Enhanced capture management. Automatic threshold accuracy demonstrated
    • on behalf of the Worldwide Kappa 900 Investigators. (abstract). International Symposium on Progress in Clinical Pacing, Rome, Italy, December
    • Bénézet J, Tscheliessnigg K, Bernanosci M, Manolis AS, Sperzel J, on behalf of the Worldwide Kappa 900 Investigators. Enhanced capture management. Automatic threshold accuracy demonstrated (abstract). International Symposium on Progress in Clinical Pacing, Rome, Italy, December 2002
    • (2002)
    • Bénézet, J.1    Tscheliessnigg, K.2    Bernanosci, M.3    Manolis, A.S.4    Sperzel, J.5
  • 14
    • 0031930123 scopus 로고    scopus 로고
    • New method of atrial and ventricular capture detection
    • Vonk BF, Van Oort G. New method of atrial and ventricular capture detection. Pacing Clin Electrophysiol 1998;21:217-222
    • (1998) Pacing Clin. Electrophysiol. , vol.21 , pp. 217-222
    • Vonk, B.F.1    Van Oort, G.2
  • 17
    • 0348112897 scopus 로고    scopus 로고
    • Atrial threshold measurement using atrial chamber reset method
    • (abstr)
    • Sheldon T, Nelson L, Vatterott P, Mead H. Atrial threshold measurement using atrial chamber reset method (abstr). Pacing Clin Electrophysiol 2000;23(Pt II):634
    • (2000) Pacing Clin. Electrophysiol. , vol.23 , Issue.PART II , pp. 634
    • Sheldon, T.1    Nelson, L.2    Vatterott, P.3    Mead, H.4
  • 19
    • 85069333312 scopus 로고    scopus 로고
    • Applicability of Medtronic Enpulse atrial capture management
    • (abstr)
    • Rueter J. Applicability of Medtronic Enpulse atrial capture management (abstr). Europace 2003;4(Suppl):A46
    • (2003) Europace , vol.4 , Issue.SUPPL.
    • Rueter, J.1
  • 20
    • 0023615056 scopus 로고
    • A comparison of the two one-sided tests procedure and the power approach for assessing the equivalence of average bioavailability
    • Schuirmann DJ. A comparison of the two one-sided tests procedure and the power approach for assessing the equivalence of average bioavailability. J Pharmacokinet Biopharm 1987;15:657-680
    • (1987) J. Pharmacokinet. Biopharm. , vol.15 , pp. 657-680
    • Schuirmann, D.J.1
  • 21
    • 0001305791 scopus 로고
    • Bio-equivalence testing: A need to rethink (reader reaction response)
    • Westlake WJ. Bio-equivalence testing: A need to rethink (reader reaction response). Biometrics 1981;37:591-593
    • (1981) Biometrics , vol.37 , pp. 591-593
    • Westlake, W.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.