메뉴 건너뛰기




Volumn 26, Issue 1 II, 2003, Pages 248-252

Atrial evoked response integral for automatic capture verification in atrial pacing

Author keywords

Autocapture; Automatic output regulation; Evoked response; Paced depolarization integral; Pacemaker

Indexed keywords

ADULT; AGED; ARTIFICIAL HEART PACEMAKER; AUTOMATION; CALIBRATION; CONFERENCE PAPER; DEVICE; ELECTROGRAPHY; EVOKED RESPONSE; FEMALE; HEART ATRIUM PACING; HEART BEAT; HEART DEPOLARIZATION; HUMAN; MAJOR CLINICAL STUDY; MALE; MICROCOMPUTER; POLARIZATION; PULSE GENERATOR; SENSOR;

EID: 0037252955     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2003.00026.x     Document Type: Conference Paper
Times cited : (15)

References (14)
  • 1
    • 0033665388 scopus 로고    scopus 로고
    • A. Benefits in projected pacemaker longevity and in pacing related costs conferred by automatic threshold tracking
    • Boriani G, Biffi M, Branzi A, et al. A. Benefits in projected pacemaker longevity and in pacing related costs conferred by automatic threshold tracking. PACE 2000; 23:1783-1787.
    • (2000) PACE , vol.23 , pp. 1783-1787
    • Boriani, G.1    Biffi, M.2    Branzi, A.3
  • 2
    • 0024235851 scopus 로고
    • Atrial capture detection with endocardial electrodes
    • Livingston A, Callaghan F, Byrd C, et al. Atrial capture detection with endocardial electrodes. PACE 1988; 11:1770-1776.
    • (1988) PACE , vol.11 , pp. 1770-1776
    • Livingston, A.1    Callaghan, F.2    Byrd, C.3
  • 3
    • 0025002167 scopus 로고
    • Alternate methods for the determination of atrial capture threshold utilizing the telemetered intracardiac electrogram
    • Feuer J, Florio J, Shandling A. Alternate methods for the determination of atrial capture threshold utilizing the telemetered intracardiac electrogram. PACE 1990; 13:1254-1260.
    • (1990) PACE , vol.13 , pp. 1254-1260
    • Feuer, J.1    Florio, J.2    Shandling, A.3
  • 4
    • 0026332266 scopus 로고
    • A method for analysis of the local atrial evoked response for determination of atrial capture in permanent pacing systems
    • Curtis A, Maas S, Domijan A, et al. A method for analysis of the local atrial evoked response for determination of atrial capture in permanent pacing systems. PACE 1991; 14:1576-1581.
    • (1991) PACE , vol.14 , pp. 1576-1581
    • Curtis, A.1    Maas, S.2    Domijan, A.3
  • 5
    • 0346221717 scopus 로고    scopus 로고
    • Clinical validation of new pacing-sensing configurations for automatic atrial capture verification in pacemakers
    • Kay G, Butter C, Hartung W, et al. Clinical validation of new pacing-sensing configurations for automatic atrial capture verification in pacemakers. (abstract) PACE 2000; 23:576.
    • (2000) PACE , vol.23 , pp. 576
    • Kay, G.1    Butter, C.2    Hartung, W.3
  • 6
    • 0347482799 scopus 로고    scopus 로고
    • Clinical test of a new method for atrial autocapture
    • Kay G, Zhang G, Hall J, et al. Clinical test of a new method for atrial autocapture. (abstract) PACE 2000; 23:636.
    • (2000) PACE , vol.23 , pp. 636
    • Kay, G.1    Zhang, G.2    Hall, J.3
  • 7
    • 0034770761 scopus 로고    scopus 로고
    • Clinical validation of new pacing-sensing configurations for atrial automatic capture verification in pacemakers
    • Butter C, Hartung W, Kay G, et al. Clinical validation of new pacing-sensing configurations for atrial automatic capture verification in pacemakers. J Cardiovasc Electrophysiol 2001; 10:1104-1108.
    • (2001) J Cardiovasc Electrophysiol , vol.10 , pp. 1104-1108
    • Butter, C.1    Hartung, W.2    Kay, G.3
  • 8
    • 0348112896 scopus 로고    scopus 로고
    • Automatic measurement of atrial pacing thresholds by AV conduction
    • Rueter J, Heymen H, Meisel E, et al. Automatic measurement of atrial pacing thresholds by AV conduction. (abstract) PACE 2000; 23:658.
    • (2000) PACE , vol.23 , pp. 658
    • Rueter, J.1    Heymen, H.2    Meisel, E.3
  • 9
    • 0348112897 scopus 로고    scopus 로고
    • Atrial threshold measurement using atrial chamber reset method
    • Sheldon T, Nelson L, Vatterott P, et al. Atrial threshold measurement using atrial chamber reset method. (abstract) PACE 2000; 23:634.
    • (2000) PACE , vol.23 , pp. 634
    • Sheldon, T.1    Nelson, L.2    Vatterott, P.3
  • 10
    • 0346852280 scopus 로고    scopus 로고
    • Atrial evoked response and polarization evaluated in a pacing system with an onboard A/D converter
    • Jalali L, Florio J, Bornzin G, et al. Atrial evoked response and polarization evaluated in a pacing system with an onboard A/D converter. (abstract) PACE 1997; 20:1096.
    • (1997) PACE , vol.20 , pp. 1096
    • Jalali, L.1    Florio, J.2    Bornzin, G.3
  • 12
    • 0012887475 scopus 로고    scopus 로고
    • Dual-chamber autocapture system algorithm that saves pacing energy and avoids fusion in patients with intact conduction
    • November
    • Bornzin GA, Florio F, Sloman L, et al. Dual-chamber autocapture system algorithm that saves pacing energy and avoids fusion in patients with intact conduction. HeartWeb Vol. 2, No. 1 November 1996.
    • (1996) HeartWeb , vol.2 , Issue.1
    • Bornzin, G.A.1    Florio, F.2    Sloman, L.3
  • 13
    • 0346852281 scopus 로고    scopus 로고
    • Pacemaker with improved automatic output regulation. US patent 4,969,462. 1990
    • Callaghan FJ, Vollmann W. Pacemaker with improved automatic output regulation. US patent 4,969,462. 1990.
    • Callaghan, F.J.1    Vollmann, W.2
  • 14
    • 0346221718 scopus 로고    scopus 로고
    • Pacemaker with improved automatic output regulation. US patent 4,969,467. 1990
    • Callaghan FJ, Vollmann W. Pacemaker with improved automatic output regulation. US patent 4,969,467. 1990.
    • Callaghan, F.J.1    Vollmann, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.