1
-
-
27744521595
-
Survey of experience with polymeric insulated power cable in underground service
-
Phase I and II (March), Phase III (October)
-
"Survey of Experience with Polymeric Insulated Power Cable in Underground Service", CEA Report No. 117-D-295, Phase I and II (March 1984), Phase III (October 1987).
-
(1984)
CEA Report No. 117-D-295
-
-
-
2
-
-
0021504579
-
Water treeing in solid dielectrics
-
M.T. Shaw, and S.H. Shaw, "Water Treeing in Solid Dielectrics", IEEE Trans. Electr. Insul., Vol. 9, pp. 419-452, 1984.
-
(1984)
IEEE Trans. Electr. Insul.
, vol.9
, pp. 419-452
-
-
Shaw, M.T.1
Shaw, S.H.2
-
3
-
-
0032180077
-
Inception and propagation mechanism of water treeing
-
R. Ross, "Inception and Propagation Mechanism of Water Treeing", IEEE Trans. Electr. Insul., Vol. 5, pp. 660-680, 1998.
-
(1998)
IEEE Trans. Electr. Insul.
, vol.5
, pp. 660-680
-
-
Ross, R.1
-
4
-
-
27744550093
-
The influence of water trees on loss factor and capacitance of medium voltage cables
-
Dresden, Germany, August 26 - 30, Paper 23.07
-
P. Romero, R. Patsch, and A. Paximadakis, "The Influence of Water Trees on Loss Factor and Capacitance of Medium Voltage Cables", Proc. of the 7th Intern. Symp. on High Voltage Engineering, Dresden, Germany, August 26 - 30, 1991, Paper 23.07.
-
(1991)
Proc. of the 7th Intern. Symp. on High Voltage Engineering
-
-
Romero, P.1
Patsch, R.2
Paximadakis, A.3
-
5
-
-
0021594468
-
The dielectric response of polyethylene cable containing water trees
-
University of Lancaster, U.K.
-
S.G. Swingler, R.J. Jackson, and J. Drysdale, "The Dielectric Response of Polyethylene Cable Containing Water Trees", Proc. of the 4th IEE Conf. on Dielectric Materials Measurements and Applications, University of Lancaster, U.K., pp.183 - 185, 1984.
-
(1984)
Proc. of the 4th IEE Conf. on Dielectric Materials Measurements and Applications
, pp. 183-185
-
-
Swingler, S.G.1
Jackson, R.J.2
Drysdale, J.3
-
7
-
-
0033724107
-
A novel compact instrument for the evaluation of relaxation currents conceived for on-site diagnosis of electrical power apparatus
-
Anaheim, CA, USA
-
J-J Alff, V. Der Houhanessian, W.S. Zaengl and A.J. Kachler, "A Novel Compact Instrument for the Evaluation of Relaxation Currents Conceived for On-site Diagnosis of Electrical Power Apparatus", Proc. 2000 IEEE Int. Symp. on Elect. Insul. (ISEI 2000), Anaheim, CA, USA, pp. 161-167, 2000.
-
(2000)
Proc. 2000 IEEE Int. Symp. on Elect. Insul. (ISEI 2000)
, pp. 161-167
-
-
Alff, J.-J.1
Der Houhanessian, V.2
Zaengl, W.S.3
Kachler, A.J.4
-
8
-
-
27744562883
-
A novel diagnostic method for buried polymer-insulated medium voltage cables
-
Yokohama, Japan
-
T. Heizman and W.S. Zaengl, "A Novel Diagnostic Method for Buried Polymer-Insulated Medium Voltage Cables", Proc. 1993 Intern. Symp. High Voltage Eng., Yokohama, Japan, pp. 185-188, 1993.
-
(1993)
Proc. 1993 Intern. Symp. High Voltage Eng.
, pp. 185-188
-
-
Heizman, T.1
Zaengl, W.S.2
-
9
-
-
0033314365
-
Return voltage - A reliable diagnosis for water treed cables
-
Austin, TX, USA
-
J. Jung, R. Patsch, and D. Kamenka, "Return Voltage - a Reliable Diagnosis for Water Treed Cables", IEEE Conf. Electrical Insulation and Dielectric Phenomena (CEIDP 1999), Austin, TX, USA, pp. 626-629, 1999.
-
(1999)
IEEE Conf. Electrical Insulation and Dielectric Phenomena (CEIDP 1999)
, pp. 626-629
-
-
Jung, J.1
Patsch, R.2
Kamenka, D.3
-
10
-
-
0033724284
-
Improvement of the return voltage method for water tree detection in XLPE cables
-
Anaheim, CA, USA
-
R. Patsch and J. Jung, "Improvement of the Return Voltage Method for Water Tree Detection in XLPE Cables", Proc. 2000 IEEE Int. Symp. on Elect. Insul. (ISEI 2000), Anaheim, CA, USA, pp. 133-136, 2000.
-
(2000)
Proc. 2000 IEEE Int. Symp. on Elect. Insul. (ISEI 2000)
, pp. 133-136
-
-
Patsch, R.1
Jung, J.2
-
11
-
-
0344115616
-
Dielectric response - A diagnostic tool for high voltage apparatus
-
August, Montreal, Canada
-
th Int. Symp. High Voltage Eng. (ISH 1997), August, Montreal, Canada, Vol. 4, pp. 393 - 396.
-
th Int. Symp. High Voltage Eng. (ISH 1997)
, vol.4
, pp. 393-396
-
-
Kuschel, M.1
Plath, R.2
Kalkner, W.3
-
12
-
-
85068343727
-
Influence on aging on depolarization currents in polymer-insulated medium-voltage cables
-
Knoxville, TN, USA
-
Th. Heizmann and W.S. Zaengl, "Influence on Aging on Depolarization Currents in Polymer-Insulated medium-Voltage Cables", Proc. 1991 Conf. on Electrical Insulation and Dielectric Phenomena (CEIDP 1991), Knoxville, TN, USA, pp. 324-329, 1991.
-
(1991)
Proc. 1991 Conf. on Electrical Insulation and Dielectric Phenomena (CEIDP 1991)
, pp. 324-329
-
-
Heizmann, Th.1
Zaengl, W.S.2
-
13
-
-
0028604182
-
Destruction free aging diagnosis of power cable insulation using the isothermal relaxation current analysis
-
Pittsburgh, PA
-
M. Beigert and H.-G. Kranz, "Destruction Free Aging Diagnosis of Power Cable Insulation Using the Isothermal Relaxation Current Analysis', Proc. ISEI 1994, Pittsburgh, PA, pp. 17-21, 1994.
-
(1994)
Proc. ISEI 1994
, pp. 17-21
-
-
Beigert, M.1
Kranz, H.-G.2
-
14
-
-
25644440906
-
IRC-analysis; A new test procedure for laid XLPE cables
-
Montreal, Canada
-
th Int. Symp. High Voltage Eng (ISH 1997), Montreal, Canada, Vol. 4, pp. 207-210, 1997.
-
(1997)
th Int. Symp. High Voltage Eng (ISH 1997)
, vol.4
, pp. 207-210
-
-
Kranz, H.-G.1
Steinbrinl, D.2
Merschel, F.3
-
15
-
-
0006630144
-
Isothermal relaxation current analysis: A New non-destructive diagnostic measurement techniques for power distribution cables
-
IEEE/PES Panel on Diagnostic Measurement Techniques for Power Cables, New Orleans, USA
-
G. Hoff and H. Kranz, "Isothermal Relaxation Current Analysis: A new Non-destructive Diagnostic Measurement Techniques for Power Distribution Cables", IEEE/PES Panel on Diagnostic Measurement Techniques for Power Cables, IEEE-PES Winter Meeting, New Orleans, USA, 1999.
-
(1999)
IEEE-PES Winter Meeting
-
-
Hoff, G.1
Kranz, H.2
-
16
-
-
84954441566
-
On-site dielectric diagnostics of power cables using the isothermal relation current measurements
-
Session on Paper 08-02-06
-
G. Hoff and H.-G. Kranz, "On-site Dielectric Diagnostics of Power Cables Using the Isothermal Relation Current Measurements", Proc. 2000 Power Engineering Society Winter Meeting, Session on Paper 08-02-06, 2000.
-
(2000)
Proc. 2000 Power Engineering Society Winter Meeting
-
-
Hoff, G.1
Kranz, H.-G.2
-
17
-
-
0032289928
-
Diagnosis of medium voltage XLPE cables by high voltage dielectric spectroscopy
-
Vasteras, Sweden
-
P. Werelius, B. Holmgren, and U. Gaefvert, "Diagnosis of Medium Voltage XLPE Cables by High Voltage Dielectric Spectroscopy", Proc. ICSD 1998, Vasteras, Sweden, pp. 79-84, 1998.
-
(1998)
Proc. ICSD 1998
, pp. 79-84
-
-
Werelius, P.1
Holmgren, B.2
Gaefvert, U.3
-
18
-
-
0344547223
-
Power cable diagnostics by dielectric spectroscopy
-
Session on Diagnostic Measurement Techniques for Power Cables, Singapore, 08-03-06
-
P. Werelius, "Power Cable Diagnostics by Dielectric Spectroscopy", Proc. 2000 Power Engineering Society Winter Meeting, Session on Diagnostic Measurement Techniques for Power Cables, Singapore, 08-03-06, 2000
-
(2000)
Proc. 2000 Power Engineering Society Winter Meeting
-
-
Werelius, P.1
-
19
-
-
0035248145
-
Dielectric spectroscopy for diagnosis of water-tree deterioration in XLPE cables
-
P. Wereelius, P. Tharning, R. Erikson, B. Holmgren and U. Gafvert, "Dielectric Spectroscopy for Diagnosis of Water-Tree Deterioration in XLPE Cables", IEEE Trans. Dielectr. Electr. Insul., Vol. 8, pp. 27-42, 2001.
-
(2001)
IEEE Trans. Dielectr. Electr. Insul.
, vol.8
, pp. 27-42
-
-
Wereelius, P.1
Tharning, P.2
Erikson, R.3
Holmgren, B.4
Gafvert, U.5
-
20
-
-
0028407699
-
Evaluation of field aged XLPE cables by PD location
-
M. Mashikian, R. Luther, J. McGiver, J. Jurcisin, and P. Spencer, "Evaluation of Field Aged XLPE Cables by PD Location". IEEE Trans. Power Del, Vol. 9, pp. 620-628, 1994.
-
(1994)
IEEE Trans. Power Del
, vol.9
, pp. 620-628
-
-
Mashikian, M.1
Luther, R.2
McGiver, J.3
Jurcisin, J.4
Spencer, P.5
-
21
-
-
0025588428
-
New approach to diagnostic method of water trees
-
Toronto, Canada
-
M. Nagao, T. Tokoro, A. Yokoyama, and M. Kosaki, "New Approach to Diagnostic Method of Water Trees", Proc. of the 1990 IEEE Intern. Symp. on Electrical Insulation, Toronto, Canada, pp. 296-299, 1990.
-
(1990)
Proc. of the 1990 IEEE Intern. Symp. on Electrical Insulation
, pp. 296-299
-
-
Nagao, M.1
Tokoro, T.2
Yokoyama, A.3
Kosaki, M.4
-
22
-
-
0028579399
-
Diagnostic measurements of high voltage insulation using current comparator technology
-
Pittsburgh, PA, USA
-
A. Bulinski, E. So, S. Bamji, Y. Chen, J. Densley, and J.-M. Braun, "Diagnostic Measurements of High Voltage Insulation Using Current Comparator Technology", Proc. of the 1994 IEEE Intern. Symp. on Electrical Insulation, Pittsburgh, PA, USA, pp. 115-118, 1994.
-
(1994)
Proc. of the 1994 IEEE Intern. Symp. on Electrical Insulation
, pp. 115-118
-
-
Bulinski, A.1
So, E.2
Bamji, S.3
Chen, Y.4
Densley, J.5
Braun, J.-M.6
-
23
-
-
84954461816
-
Measurement of the harmonic distortion of the insulation loss current as a diagnostic tool for high voltage cable insulation
-
Session on Diagnostic Measurement Techniques for Power Cables, Singapore, Paper 08-06-06
-
A. Bulinski, E. So, and S. Bamji, "Measurement of the Harmonic Distortion of the Insulation Loss Current as a Diagnostic Tool for High Voltage Cable Insulation", Proc. 2000 Power Engineering Society Winter Meeting, Session on Diagnostic Measurement Techniques for Power Cables, Singapore, Paper 08-06-06, 2000.
-
(2000)
Proc. 2000 Power Engineering Society Winter Meeting
-
-
Bulinski, A.1
So, E.2
Bamji, S.3
-
24
-
-
0242720703
-
Dielectric spectroscopy in time and frequency domain for HV power equipment, Part 1: Theoretical considerations
-
W. Zaengl, "Dielectric Spectroscopy in Time and Frequency Domain for HV Power Equipment, Part 1: Theoretical Considerations", IEEE Electrical Insulation Magazine, Vol. 19, No. 5, pp. 5-19, 2003.
-
(2003)
IEEE Electrical Insulation Magazine
, vol.19
, Issue.5
, pp. 5-19
-
-
Zaengl, W.1
-
25
-
-
1242330865
-
Applications of dielectric spectroscopy in time and frequency domain for HV power equipment
-
W. Zaengl, "Applications of Dielectric Spectroscopy in time and Frequency Domain for HV Power Equipment", IEEE Electrical Insulation Magazine, Vol. 19, No. 6, pp. 9-22, 2003.
-
(2003)
IEEE Electrical Insulation Magazine
, vol.19
, Issue.6
, pp. 9-22
-
-
Zaengl, W.1
-
26
-
-
84954433819
-
An overview of aging mechanisms and dignostics for extruded power cables
-
Session on Diagnostic Measurement Techniques for Power Cables, Singapore, Paper 08-01-06
-
J. Densley, "An Overview of Aging Mechanisms and Dignostics for Extruded Power Cables", Proc. 2000 Power Engineering Society Winter Meeting, Session on Diagnostic Measurement Techniques for Power Cables, Singapore, Paper 08-01-06, 2000.
-
(2000)
Proc. 2000 Power Engineering Society Winter Meeting
-
-
Densley, J.1
-
27
-
-
0028732594
-
Water treeing in binary linear polyethylene blends - The mechanical aspect
-
A.T. Bulinski, S. Bamji, J. Densley, A. Gustafsson, and U.W. Gedde, "Water Treeing in Binary Linear Polyethylene Blends - the Mechanical Aspect". IEEE Trans. Elect. Insul., Vol. 1, pp. 949-962, 1994.
-
(1994)
IEEE Trans. Elect. Insul.
, vol.1
, pp. 949-962
-
-
Bulinski, A.T.1
Bamji, S.2
Densley, J.3
Gustafsson, A.4
Gedde, U.W.5
-
28
-
-
0032139949
-
Polymer oxidation and water treeing
-
A.T. Bulinski, J.-P. Crine, B. Noirhomme, J. Densley, and S. Bamji, "Polymer Oxidation and Water Treeing", IEEE Trans. Dielect. Electr. Insul., Vol. 5, pp. 558-570, 1998.
-
(1998)
IEEE Trans. Dielect. Electr. Insul.
, vol.5
, pp. 558-570
-
-
Bulinski, A.T.1
Crine, J.-P.2
Noirhomme, B.3
Densley, J.4
Bamji, S.5
|