메뉴 건너뛰기




Volumn 3, Issue , 2000, Pages 1615-1620

Measurement of the harmonic distortion of the insulation loss current as a diagnostic tool for high voltage cable insulation

Author keywords

aging; current comparator; diagnostic measurements; dielectric losses; harmonics; High voltage cable; water treeing

Indexed keywords

AGING OF MATERIALS; CABLES; CAPACITANCE; COMPARATOR CIRCUITS; COMPARATORS (OPTICAL); DIELECTRIC LOSSES; FORESTRY; HARMONIC ANALYSIS; HARMONIC DISTORTION; INSULATING MATERIALS; UNDERGROUND CABLES;

EID: 84954461816     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PESW.2000.847584     Document Type: Conference Paper
Times cited : (18)

References (21)
  • 1
    • 27744521595 scopus 로고
    • Survey of Experience with Polymeric Insulated Power Cable in Underground Service
    • Phase I and II March Phase III October
    • "Survey of Experience with Polymeric Insulated Power Cable in Underground Service", CEA Report No. 117-D-295, Phase I and II (March 1984), Phase III (October 1987).
    • (1984) CEA Report
  • 2
    • 0021504579 scopus 로고
    • Water Treeing in Solid Dielectrics
    • M.T. Shaw, and S.H. Shaw, "Water Treeing in Solid Dielectrics", IEEE Trans. Electr. Insul., Vol. EI-9,No.5, 1984, pp. 419-452.
    • (1984) IEEE Trans. Electr. Insul. , vol.EI-9 , Issue.5 , pp. 419-452
    • Shaw, M.T.1    Shaw, S.H.2
  • 3
    • 0032180077 scopus 로고    scopus 로고
    • Inception and Propagation Mechanism of Water Treeing
    • R. Ross, "Inception and Propagation Mechanism of Water Treeing", IEEE Trans. Electr. Insul., Vol. 5, No.5, 1998, pp. 660-680.
    • (1998) IEEE Trans. Electr. Insul. , vol.5 , Issue.5 , pp. 660-680
    • Ross, R.1
  • 4
    • 84954426048 scopus 로고    scopus 로고
    • Very Low Frequency Cable Testing: Combining Cable Quality Analusis and Selective Breakdown of Water Trees
    • O. Goll, "Very Low Frequency Cable Testing: Combining Cable Quality Analusis and Selective Breakdown of Water Trees", Part I: Electricity Today, Vol. 9, No. 6, pp. 16-17,
    • Part I: Electricity Today , vol.9 , Issue.6 , pp. 16-17
    • Goll, O.1
  • 6
    • 0028604182 scopus 로고
    • Destruction Free Ageing Diagnosis of Power Cable Insulation Using the Isothermal Relaxation Current Analysis
    • Pittsburgh, PA, June 5-8
    • M. Beigert and H.-G. Kranz, "Destruction Free Ageing Diagnosis of Power Cable Insulation Using the Isothermal Relaxation Current Analysis," Proc. 1994 IEEE Intern. Symp. on Electrical Insulation, Pittsburgh, PA, June 5-8, 1994, pp. 17-21.
    • (1994) Proc. 1994 IEEE Intern. Symp. on Electrical Insulation , pp. 17-21
    • Beigert, M.1    Kranz, H.-G.2
  • 9
    • 27744562883 scopus 로고
    • A Novel Diagnostic Method for Buried Polymer-Insulated Medium Voltage Cables
    • Yokohama, Japan,August23-27
    • T. Heizman and W.S. Zaengl, "A Novel Diagnostic Method for Buried Polymer-Insulated Medium Voltage Cables", Proc. 1993 Intern. Symp. High Voltage Eng., Yokohama, Japan,August23-27, 1993, pp. 185-188.
    • (1993) Proc. 1993 Intern. Symp. High Voltage Eng. , pp. 185-188
    • Heizman, T.1    Zaengl, W.S.2
  • 11
    • 27744550093 scopus 로고
    • The Influence of Water Trees on Loss Factor and Capacitance of Medium Voltage Cables
    • Dresden, Germany, August 26-30, Paper 23.07
    • P. Romero, R. Patsch, and A. Paximadakis, "The Influence of Water Trees on Loss Factor and Capacitance of Medium Voltage Cables", Proc. of the 7th Intern. Symp. on High Voltage Engineering, Dresden, Germany, August 26-30, 1991, Paper 23.07.
    • (1991) Proc. of the 7th Intern. Symp. on High Voltage Engineering
    • Romero, P.1    Patsch, R.2    Paximadakis, A.3
  • 16
    • 84954461389 scopus 로고
    • URD Can Be Protected From Early Failure
    • July
    • B. Smith, "URD Can Be Protected From Early Failure", Transmission and Distribution, July 1989, pp. 60-62.
    • (1989) Transmission and Distribution , pp. 60-62
    • Smith, B.1
  • 21
    • 0019606554 scopus 로고
    • The Voltage Breakdown Characteristics of Miniature XLPE Cables Containing Water Trees
    • A. Bulinski and J. Densley, "The Voltage Breakdown Characteristics of Miniature XLPE Cables Containing Water Trees", IEEE Trans. Elect. Insulation, Vol. EI-16, No. 4, 1981, pp. 319-325.
    • (1981) IEEE Trans. Elect. Insulation , vol.EI-16 , Issue.4 , pp. 319-325
    • Bulinski, A.1    Densley, J.2