메뉴 건너뛰기




Volumn 75, Issue 3, 2005, Pages 267-278

Synthetic membrane coronary stent graft in coronary disease;Aplicaciones del stent cubierto con membrana de politetrafluoroetileno en el intervencionismo coronario (Experiencia del Instituto Nacional de Cardiología "Ignacio Chávez")

Author keywords

Coronary stent graft; Covered stent; PTFE stent

Indexed keywords

POLITEF;

EID: 27644551031     PISSN: 14059940     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (36)
  • 2
    • 0029151208 scopus 로고
    • Predictor's and sequelae of distal embolization during saphenous vein graft intervention from the CAVEAT-II trial
    • LEFKOVITS J, HOLMES RD, CALIFF RM, SAFIAN RD, PIEPER K, KEELER G, TOPOL EJ: Predictor's and sequelae of distal embolization during saphenous vein graft intervention from the CAVEAT-II trial. Circulation 1995; 92: 734-740.
    • (1995) Circulation , vol.92 , pp. 734-740
    • Lefkovits, J.1    Holmes, R.D.2    Califf, R.M.3    Safian, R.D.4    Pieper, K.5    Keeler, G.6    Topol, E.J.7
  • 3
    • 0027405744 scopus 로고
    • Intracoronary artery thrombus formation in unstable angina: A clinical, biochemical and angiographic correlation
    • WILENSKY R, BOURDILLON P, VERNON AV, SELLER JA: Intracoronary artery thrombus formation in unstable angina: a clinical, biochemical and angiographic correlation. J Am Coll Cardiol 1993; 21: 692-699.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 692-699
    • Wilensky, R.1    Bourdillon, P.2    Vernon, A.V.3    Seller, J.A.4
  • 6
    • 0023153178 scopus 로고
    • Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty
    • SIGWART U, PUEL J, MIRKOVITH V, JOFFRE F, KAPPENBERGER L: Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N Engl J Med 1987; 316: 701-706.
    • (1987) N Engl J Med , vol.316 , pp. 701-706
    • Sigwart, U.1    Puel, J.2    Mirkovith, V.3    Joffre, F.4    Kappenberger, L.5
  • 13
    • 0001596926 scopus 로고    scopus 로고
    • The New Coronary Stent Graft Jostent: First clinical experience
    • GERCKENS U, MÜLLER R, CATTELAENS M, GRUBE E: The New Coronary Stent Graft Jostent: First clinical experience. J Am Coll Cardiol 1998; 31(2); Suppl A: 414A.
    • (1998) J Am Coll Cardiol , vol.31 , Issue.2 SUPPL. A
    • Gerckens, U.1    Müller, R.2    Cattelaens, M.3    Grube, E.4
  • 14
    • 0033180262 scopus 로고    scopus 로고
    • Coronary stent grafts covered by a polytetrafluoroethylene membrane
    • ELSNER M, AUCH-SCHWELK W, BRITTEN M: Coronary stent grafts covered by a polytetrafluoroethylene membrane. Am J Cardiol 1999; 84: 335-338.
    • (1999) Am J Cardiol , vol.84 , pp. 335-338
    • Elsner, M.1    Auch-Schwelk, W.2    Britten, M.3
  • 15
    • 0032731715 scopus 로고    scopus 로고
    • Polytetrafluoroethylene-Covered stents: Indications, Advantages and limitations
    • STÖRGER H, HAASE J: Polytetrafluoroethylene-Covered stents: Indications, Advantages and limitations. J Interven Cardiol 1999; 12: 451-456.
    • (1999) J Interven Cardiol , vol.12 , pp. 451-456
    • Störger, H.1    Haase, J.2
  • 16
    • 0342859299 scopus 로고    scopus 로고
    • Membrane-covered stents for the treatment of aorto-coronary vein graft disease
    • BALDUS S, KÖSTER R, REIMERS J, HAMM CW: Membrane-covered stents for the treatment of aorto-coronary vein graft disease. Cathet Cardiovasc Intervent 2000; 50: 83-88.
    • (2000) Cathet Cardiovasc Intervent , vol.50 , pp. 83-88
    • Baldus, S.1    Köster, R.2    Reimers, J.3    Hamm, C.W.4
  • 21
    • 20144368666 scopus 로고    scopus 로고
    • A Prospective, Randomized U.S. Trial of the PTFE Covered JOSTENT for the Treatment of Diseased Saphenous Vein Grafts: The BARRICADE Trial
    • Columbia University Medical Center, New York, NY. Cardiovascular Research Foundation, New York, NY: Feb 2005
    • STONE GW, GOLDBERG S, MEHRAN R, O'SHAUGHNESSY CH, MIDEL M, SIEGEL R, GEORGE B, SATLER L, RAIZNER A, NEGOITA M, FAHY M, ARJOMAND-FARD H, LANSKY AJ: Columbia University Medical Center, New York, NY. Cardiovascular Research Foundation, New York, NY: A Prospective, Randomized U.S. Trial of the PTFE Covered JOSTENT for the Treatment of Diseased Saphenous Vein Grafts: The BARRICADE Trial. J Am Coll Cardiol 2005; (Suppl) Feb 2005: 27A.
    • (2005) J Am Coll Cardiol , Issue.SUPPL.
    • Stone, G.W.1    Goldberg, S.2    Mehran, R.3    O'Shaughnessy, Ch.4    Midel, M.5    Siegel, R.6    George, B.7    Satler, L.8    Raizner, A.9    Negoita, M.10    Fahy, M.11    Arjomand-Fard, H.12    Lansky, A.J.13
  • 22
    • 0027512611 scopus 로고
    • Intravascular ultrasound diagnosis of a coronary artery pseudoaneurysm following percutaneous transluminal coronary angioplasty
    • GAZZAND TJ, MINTZ GS, POPMA JJ: Intravascular ultrasound diagnosis of a coronary artery pseudoaneurysm following percutaneous transluminal coronary angioplasty. Am Heart J 1993; 125: 880-882.
    • (1993) Am Heart J , vol.125 , pp. 880-882
    • Gazzand, T.J.1    Mintz, G.S.2    Popma, J.J.3
  • 24
    • 0017168886 scopus 로고
    • Recognition and operative management of patients with arteriosclerotic coronary artery aneurysms
    • ALFORD WC, STONEY WS, BURRUS GR: Recognition and operative management of patients with arteriosclerotic coronary artery aneurysms. Ann Thorac Surg 1976; 22: 317-321.
    • (1976) Ann Thorac Surg , vol.22 , pp. 317-321
    • Alford, W.C.1    Stoney, W.S.2    Burrus, G.R.3
  • 25
    • 0028798949 scopus 로고
    • Percutaneous transcatheter repair of a coronary aneurysm using a composite autologous cephalic vein-coated Palmaz-Schatz biliary stent
    • WONG SC, KENT KM, MINTZ GS: Percutaneous transcatheter repair of a coronary aneurysm using a composite autologous cephalic vein-coated Palmaz-Schatz biliary stent. Am J Cardiol 1995; 76: 990-991.
    • (1995) Am J Cardiol , vol.76 , pp. 990-991
    • Wong, S.C.1    Kent, K.M.2    Mintz, G.S.3
  • 28
    • 0036256508 scopus 로고    scopus 로고
    • Treatment of a giant coronary aneurysm with a novel technique: Scaffolding (tunnel) stenting to support PTFE-covered stents: Insights from intravascular ultrasound catheter techniques for the treatment of aneurysms and Pseudoaneurysms
    • LÓPEZ MM, ALFONSO F, FERNÁNDEZ OA, ESCANED J, FLORES A, GARCÍA P, ARIAS J, HERNÁNDEZ R, MACAYA C: Treatment of a giant coronary aneurysm with a novel technique: Scaffolding (tunnel) stenting to support PTFE-covered stents: Insights from intravascular ultrasound catheter techniques for the treatment of aneurysms and Pseudoaneurysms. J Invasive Cardiol 2002; 14(5): 273-276.
    • (2002) J Invasive Cardiol , vol.14 , Issue.5 , pp. 273-276
    • López, M.M.1    Alfonso, F.2    Fernández, O.A.3    Escaned, J.4    Flores, A.5    García, P.6    Arias, J.7    Hernández, R.8    Macaya, C.9
  • 29
    • 0028307660 scopus 로고
    • Perforation after percutaneous coronary interventions: Clinical, angiographic, and therapeutic observations
    • AJLUNI SC, GLAZIER S, BLANKENSHIP L: Perforation after percutaneous coronary interventions: clinical, angiographic, and therapeutic observations. Cathet Cardiovasc Diagn 1994; 32: 206-212.
    • (1994) Cathet Cardiovasc Diagn , vol.32 , pp. 206-212
    • Ajluni, S.C.1    Glazier, S.2    Blankenship, L.3
  • 31
    • 4243375133 scopus 로고
    • Factors associated with procedural complications during high pressure optimized Palmaz-Schatz intracoronary stent implantation
    • HALL P, NAKAMURA S, MAIELLO L: Factors associated with procedural complications during high pressure optimized Palmaz-Schatz intracoronary stent implantation. Circulation 1994; 90(Suppl): 1-612.
    • (1994) Circulation , vol.90 , Issue.SUPPL. , pp. 1-612
    • Hall, P.1    Nakamura, S.2    Maiello, L.3
  • 32
    • 0034702180 scopus 로고    scopus 로고
    • Coronary Artery Rupture treated with a polytetrafluoroethylene-coated stent
    • NAGEH T, THOMAS MR: Coronary Artery Rupture treated with a polytetrafluoroethylene-coated stent. N Engl J Med 2000; 342, 25: 1922-1923.
    • (2000) N Engl J Med , vol.342 , Issue.25 , pp. 1922-1923
    • Nageh, T.1    Thomas, M.R.2
  • 34
    • 0034687590 scopus 로고    scopus 로고
    • Emergency polytetrafluoroethylene covered stent implantation to treat coronary ruptures
    • BRIGUORI C, NISHIDA T, ANZUINI A, DI MARIO C, GRUBE E, COLOMBO A: Emergency polytetrafluoroethylene covered stent implantation to treat coronary ruptures. Circulation 2000; 102: 3028-3031.
    • (2000) Circulation , vol.102 , pp. 3028-3031
    • Briguori, C.1    Nishida, T.2    Anzuini, A.3    Di Mario, C.4    Grube, E.5    Colombo, A.6
  • 36
    • 0043075814 scopus 로고    scopus 로고
    • Randomized comparison of distal protection with a filter based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts
    • STONE GW, ROGERS C, HERMILLER J, FELDMAN R, HELL P, HABER R, MASUD A, RAMEE S, COX D: Randomized comparison of distal protection with a filter based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts. Circulation 2003; 108: 548-553.
    • (2003) Circulation , vol.108 , pp. 548-553
    • Stone, G.W.1    Rogers, C.2    Hermiller, J.3    Feldman, R.4    Hell, P.5    Haber, R.6    Masud, A.7    Ramee, S.8    Cox, D.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.