Volumn 93, Issue 3, 1996, Pages 412-422

Heparin-coated Palmaz-Schatz stents in human coronary arteries: Early outcome of the Benestent-II pilot study

Author keywords

angina; anticoagulants; coating; heparin; stents

Indexed keywords

ACETYLSALICYLIC ACID; HEPARIN; TICLOPIDINE; WARFARIN;

EID: 9044251603     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.93.3.412     Document Type: Article
Times cited : (392)

References (46)
  • 1
    • 0024446850 scopus 로고
    • Stenting of coronary arteries: Are we the sorcerer's apprentice?
    • Serruys PW, Beatt KJ, Van der Giessen WJ. Stenting of coronary arteries: are we the sorcerer's apprentice? Eur Heart J. 1989;10: 774-782.
    • (1989) Eur Heart J. , vol.10 , pp. 774-782
    • Serruys, P.W.1    Beatt, K.J.2    Van Der Giessen, W.J.3
  • 4
    • 0028944065 scopus 로고
    • Who was thrombogenic: The stent or the doctor?
    • Serruys PW, Di Mario C. Who was thrombogenic: the stent or the doctor? Circulation. 1995;91:1891-1893.
    • (1995) Circulation , vol.91 , pp. 1891-1893
    • Serruys, P.W.1    Di Mario, C.2
  • 5
    • 0001736853 scopus 로고
    • Heparin coating of endovascular stents decreases subacute thrombosis in a rabbit model
    • Abstract
    • Bailey SR, Paige S, Lunn AC, Palmaz J. Heparin coating of endovascular stents decreases subacute thrombosis in a rabbit model. Circulation. 1992;86(suppl I):I-186. Abstract.
    • (1992) Circulation , vol.86 , Issue.1 SUPPL.
    • Bailey, S.R.1    Paige, S.2    Lunn, A.C.3    Palmaz, J.4
  • 6
    • 0000850959 scopus 로고
    • Improved thromboresistance of heparin-coated Palmaz-Schatz coronary stents in an animal model
    • Abstract
    • Stratienko AA, Zhu D, Lambert CR, Palmaz J, Schatz RA, Santamore WP. Improved thromboresistance of heparin-coated Palmaz-Schatz coronary stents in an animal model. Circulation. 1993;88(Pt 2):I-596. Abstract.
    • (1993) Circulation , vol.88 , Issue.2 PART
    • Stratienko, A.A.1    Zhu, D.2    Lambert, C.R.3    Palmaz, J.4    Schatz, R.A.5    Santamore, W.P.6
  • 9
  • 10
  • 13
    • 0022035942 scopus 로고
    • Estimation of a common effect parameter from sparse follow-up data
    • Greenland S, Robins JM. Estimation of a common effect parameter from sparse follow-up data. Biometrics. 1985;41:55-68.
    • (1985) Biometrics , vol.41 , pp. 55-68
    • Greenland, S.1    Robins, J.M.2
  • 16
    • 0022004194 scopus 로고
    • Heparin-like molecules with anticoagulant activity are synthesized by cultured endothelial cells
    • Marcum JA, Rosenberg RD. Heparin-like molecules with anticoagulant activity are synthesized by cultured endothelial cells. Biochem Biophys Res Commun. 1985;126:365-372.
    • (1985) Biochem Biophys Res Commun. , vol.126 , pp. 365-372
    • Marcum, J.A.1    Rosenberg, R.D.2
  • 17
    • 0018760408 scopus 로고
    • Binding of human thrombin to cultured human endothelial cells
    • Awbrey B, Hoak JC, Owen WG. Binding of human thrombin to cultured human endothelial cells. J Biol Chem. 1979;254:4092-4095.
    • (1979) J Biol Chem. , vol.254 , pp. 4092-4095
    • Awbrey, B.1    Hoak, J.C.2    Owen, W.G.3
  • 18
    • 0021428955 scopus 로고
    • A canine ex vivo series shunt experiment for evaluating thrombus deposition on polymer surfaces
    • Lelah MD, Lambracht LK, Cooper SL. A canine ex vivo series shunt experiment for evaluating thrombus deposition on polymer surfaces. J Biomed Mater Res. 1984;18:475-496.
    • (1984) J Biomed Mater Res. , vol.18 , pp. 475-496
    • Lelah, M.D.1    Lambracht, L.K.2    Cooper, S.L.3
  • 19
    • 0024438976 scopus 로고
    • Cardiopulmonary bypass without systemic heparinization
    • Von Segesser LK, Turina M. Cardiopulmonary bypass without systemic heparinization. J Thorac Cardiovasc Surg. 1989;98:386-396.
    • (1989) J Thorac Cardiovasc Surg. , vol.98 , pp. 386-396
    • Von Segesser, L.K.1    Turina, M.2
  • 20
    • 0025666690 scopus 로고
    • Surface tension effects of heparin coating on arterial line filters
    • Palanzo DA, Kurusz M, Butler BD. Surface tension effects of heparin coating on arterial line filters. Perfusion. 1990;5:277-284.
    • (1990) Perfusion , vol.5 , pp. 277-284
    • Palanzo, D.A.1    Kurusz, M.2    Butler, B.D.3
  • 22
    • 0025936767 scopus 로고
    • Principles of heparin-coating techniques
    • Hsu L-C. Principles of heparin-coating techniques. Perfusion. 1991; 6:209-219.
    • (1991) Perfusion , vol.6 , pp. 209-219
    • Hsu, L.-C.1
  • 24
    • 0020108082 scopus 로고
    • Further characterization of the antithrombin-binding sequence in heparin
    • Thunberg L, Bäckström G, Lindahl U. Further characterization of the antithrombin-binding sequence in heparin. Carbohydr Res. 1982;100:393-410.
    • (1982) Carbohydr Res. , vol.100 , pp. 393-410
    • Thunberg, L.1    Bäckström, G.2    Lindahl, U.3
  • 25
    • 0025962740 scopus 로고
    • Antithrombin: Structure and function
    • Pratt CW, Church FC. Antithrombin: structure and function. Semin Hematol. 1991;28:3-9.
    • (1991) Semin Hematol. , vol.28 , pp. 3-9
    • Pratt, C.W.1    Church, F.C.2
  • 28
    • 0015538729 scopus 로고
    • Preparation and evaluation of a new antithromhogenic heparinized hydrophyllic polymer for use in cardiovascular systems
    • Tanzawa H, Mori Y, Harumiyua N, Miyama H, Hori M. Preparation and evaluation of a new antithromhogenic heparinized hydrophyllic polymer for use in cardiovascular systems. Trans Am Soc Artif Intern Organs. 1973;19:1888-1894.
    • (1973) Trans Am Soc Artif Intern Organs , vol.19 , pp. 1888-1894
    • Tanzawa, H.1    Mori, Y.2    Harumiyua, N.3    Miyama, H.4    Hori, M.5
  • 29
    • 0342289344 scopus 로고
    • Heparin-containing and heparin-like polymers
    • Chiellini E, Giusti P, eds. New York, NY: Plenum Press
    • Jozefowicz M, Jozefowicz J. Heparin-containing and heparin-like polymers. In: Chiellini E, Giusti P, eds. Polymers in Medicine. New York, NY: Plenum Press; 1983.
    • (1983) Polymers in Medicine
    • Jozefowicz, M.1    Jozefowicz, J.2
  • 30
    • 0017461859 scopus 로고
    • Properties of heparin-poly(metyl methacrylate)copolymer
    • Labarre D, Boffa MC, Jozefowicz M. Properties of heparin-poly(metyl methacrylate)copolymer. J Biomed Mater Res. 1977;11: 283-295.
    • (1977) J Biomed Mater Res. , vol.11 , pp. 283-295
    • Labarre, D.1    Boffa, M.C.2    Jozefowicz, M.3
  • 33
    • 0021040217 scopus 로고
    • A new non-thrombogenic surface prepared by selective covalent binding of heparin via a modified reducing terminal residue
    • Larm O, Larsson R, Olsson P. A new non-thrombogenic surface prepared by selective covalent binding of heparin via a modified reducing terminal residue. Biomater Med Devices Artif Organs. 1983; 11:161-173.
    • (1983) Biomater Med Devices Artif Organs , vol.11 , pp. 161-173
    • Larm, O.1    Larsson, R.2    Olsson, P.3
  • 34
    • 0021106147 scopus 로고
    • A new method for covalent coupling of heparin and other glycosaminoglycans to substances containing primary amino groups
    • Hoffman J, Larm O, Scholander E. A new method for covalent coupling of heparin and other glycosaminoglycans to substances containing primary amino groups. Carbohdyr Res. 1983;117: 328-331.
    • (1983) Carbohdyr Res. , vol.117 , pp. 328-331
    • Hoffman, J.1    Larm, O.2    Scholander, E.3
  • 36
    • 0023632693 scopus 로고
    • The search for thromboresistance using immobilized heparin
    • Larsson R, Larm O, Olsson P. The search for thromboresistance using immobilized heparin. Ann NY Acad Sci. 1987;516:102-115.
    • (1987) Ann NY Acad Sci. , vol.516 , pp. 102-115
    • Larsson, R.1    Larm, O.2    Olsson, P.3
  • 41
    • 15844424881 scopus 로고    scopus 로고
    • Platelet activation and coronary stent implantation: Effect of antithrombotic therapy
    • In press
    • Gawaz M, Neumann F, Ott I, May A, Schömig A. Platelet activation and coronary stent implantation: effect of antithrombotic therapy. Circulation. In press.
    • Circulation
    • Gawaz, M.1    Neumann, F.2    Ott, I.3    May, A.4    Schömig, A.5
  • 43
    • 0028065082 scopus 로고
    • Influence of coronary vessel size on renarrowing process and late angiographic outcome after successful balloon angioplasty
    • Foley DP, Melkert R, Serruys PW. Influence of coronary vessel size on renarrowing process and late angiographic outcome after successful balloon angioplasty. Circulation. 1994;90:1239-1251.
    • (1994) Circulation , vol.90 , pp. 1239-1251
    • Foley, D.P.1    Melkert, R.2    Serruys, P.W.3
  • 44
    • 85035156069 scopus 로고    scopus 로고
    • Palmaz-Schatz balloon-expandable stent and delivery system: PMA 900043 Panel Package: Circulatory System Devices Panel: May 3, 1994: Division of Cardiovascular, Respiratory and Neurológical Devices: US Food and Drug Administration
    • Palmaz-Schatz balloon-expandable stent and delivery system: PMA 900043 Panel Package: Circulatory System Devices Panel: May 3, 1994: Division of Cardiovascular, Respiratory and Neurológical Devices: US Food and Drug Administration.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.