메뉴 건너뛰기




Volumn 62, Issue 21, 2005, Pages 2271-2277

Effects of extreme temperatures on drug delivery of albuterol sulfate hydrofluoroalkane inhalation aerosols

Author keywords

Aerosols; Albuterol sulfate; Dosage; Hydrofluoroalkanes; Inhalers; Particle size; Propellants; Stability; Storage; Sympathomimetic agents; Temperature

Indexed keywords

FLUORINATED HYDROCARBON; PROPELLANT; SALBUTAMOL; SALBUTAMOL SULFATE;

EID: 27644472297     PISSN: 10792082     EISSN: None     Source Type: Journal    
DOI: 10.2146/ajhp050067     Document Type: Article
Times cited : (19)

References (11)
  • 1
    • 0032484265 scopus 로고    scopus 로고
    • Forecasted state-specific estimates of self-reported asthma prevalence-United States, 1998
    • Centers for Disease Control and Prevention. Forecasted state-specific estimates of self-reported asthma prevalence-United States, 1998. MMWR. 1998; 47:1022-5.
    • (1998) MMWR , vol.47 , pp. 1022-1025
  • 2
    • 23944462063 scopus 로고    scopus 로고
    • Reinventing metered dose inhalers: From poorly efficient CFC MDIs to highly efficient HFA MDIs
    • Stein SW, Stefley JS. Reinventing metered dose inhalers: from poorly efficient CFC MDIs to highly efficient HFA MDIs. Drug Deliv Technol 2003; 3:46-51.
    • (2003) Drug Deliv Technol , vol.3 , pp. 46-51
    • Stein, S.W.1    Stefley, J.S.2
  • 5
    • 0037822677 scopus 로고    scopus 로고
    • Analytical development and testing
    • Purewal TS, Grant DJ, eds. Buffalo Grove, IL: Interpharm
    • Cummings RH, Childers AG, Riebe MT. Analytical development and testing. In: Purewal TS, Grant DJ, eds. Metered dose inhaler technology. 1st ed. Buffalo Grove, IL: Interpharm; 1998:94,153-5.
    • (1998) Metered Dose Inhaler Technology. 1st Ed. , vol.94 , pp. 153-155
    • Cummings, R.H.1    Childers, A.G.2    Riebe, M.T.3
  • 7
    • 0038471182 scopus 로고    scopus 로고
    • Evaluation of a new aerodynamic particle sizer for size distribution measurements of solution metered dose inhalers
    • Stein SW, Myrdal PB, Gabrio BJ et al. Evaluation of a new aerodynamic particle sizer for size distribution measurements of solution metered dose inhalers. J Aerosol Med. 2003; 16:107-19.
    • (2003) J Aerosol Med , vol.16 , pp. 107-119
    • Stein, S.W.1    Myrdal, P.B.2    Gabrio, B.J.3
  • 8
    • 5444266295 scopus 로고    scopus 로고
    • Comparison of the TSI model 3306 impactor inlet with the Andersen cascade impactor: Solution metered dose inhalers
    • Myrdal PB, Stein SW, Mogalian E et al. Comparison of the TSI model 3306 impactor inlet with the Andersen cascade impactor: solution metered dose inhalers. Drug Dev Ind Pharm. 2004; 30:859-68.
    • (2004) Drug Dev Ind Pharm , vol.30 , pp. 859-868
    • Myrdal, P.B.1    Stein, S.W.2    Mogalian, E.3
  • 9
    • 0038471153 scopus 로고    scopus 로고
    • Balancing ethanol cosolvent concentration with product performance in 134a-based pressurized metered dose inhalers
    • Gupta A, Stein SW, Myrdal PB. Balancing ethanol cosolvent concentration with product performance in 134a-based pressurized metered dose inhalers. J Aerosol Med. 2003; 16:167-74.
    • (2003) J Aerosol Med , vol.16 , pp. 167-174
    • Gupta, A.1    Stein, S.W.2    Myrdal, P.B.3
  • 10
    • 0025806355 scopus 로고
    • Effect of canister temperature on performance of metered-dose inhalers
    • Wilson AF, Mukai DS, Ahdout JJ. Effect of canister temperature on performance of metered-dose inhalers. Am Rev Respir Dis. 1991; 143:1034-7.
    • (1991) Am Rev Respir Dis , vol.143 , pp. 1034-1037
    • Wilson, A.F.1    Mukai, D.S.2    Ahdout, J.J.3
  • 11
    • 0027301086 scopus 로고
    • Effect of vapour pressure on the deposition pattern from solution phase metered dose inhalers
    • Harnor KJ, Perkins AC, Wastie M et al. Effect of vapour pressure on the deposition pattern from solution phase metered dose inhalers. Int J Pharm. 1993; 95:111-6.
    • (1993) Int J Pharm , vol.95 , pp. 111-116
    • Harnor, K.J.1    Perkins, A.C.2    Wastie, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.