메뉴 건너뛰기




Volumn 30, Issue 8, 2004, Pages 859-868

Comparison of the TSI model 3306 impactor inlet with the Andersen cascade impactor: Solution metered dose inhalers

Author keywords

Andersen cascade impactor; Impactor inlet; MDI; Metered dose inhaler

Indexed keywords

ALCOHOL; BECLOMETASONE DIPROPIONATE;

EID: 5444266295     PISSN: 03639045     EISSN: None     Source Type: Journal    
DOI: 10.1081/DDC-200034575     Document Type: Article
Times cited : (13)

References (12)
  • 1
    • 5444245169 scopus 로고    scopus 로고
    • United States Pharmacopeial Convention: Rockville, MD
    • United States Pharmacopeia. USP26/NF21. 〈'601〉 Aerosols; United States Pharmacopeial Convention: Rockville, MD, 2003.
    • (2003) USP26/NF21. 〈'601〉 Aerosols
  • 2
    • 0023493094 scopus 로고
    • The twin impinger: A simple devise for assessing the delivery of drugs from metered dose pressurized aerosol inhalers
    • Hallworth, G.W.; Westmorland, D.G. The twin impinger: a simple devise for assessing the delivery of drugs from metered dose pressurized aerosol inhalers. J. Pharm. Pharmacol. 1987, 39, 966-972.
    • (1987) J. Pharm. Pharmacol. , vol.39 , pp. 966-972
    • Hallworth, G.W.1    Westmorland, D.G.2
  • 3
    • 0036284707 scopus 로고    scopus 로고
    • An evaluation of mass-weighted size distribution measurements with the Model 3320 aerodynamic particle sizer
    • Stein, S.W.; Gabrio, B.J.; Oberreit, D.; Hairston, P.; Myrdal, P.B.; Beck, T.J. An evaluation of mass-weighted size distribution measurements with the Model 3320 aerodynamic particle sizer. Aerosol Sci. Technol. 2002, 36, 1-10.
    • (2002) Aerosol Sci. Technol. , vol.36 , pp. 1-10
    • Stein, S.W.1    Gabrio, B.J.2    Oberreit, D.3    Hairston, P.4    Myrdal, P.B.5    Beck, T.J.6
  • 4
    • 0038471182 scopus 로고    scopus 로고
    • Evaluation of a new aerodynamic particle sizer spectrometer for size distribution measurement of solution metered dose inhalers
    • Stein, S.W.; Myrdal, P.E.; Gabrio, B.J.; Obereit, D.; Beck, T.J. Evaluation of a new aerodynamic particle sizer spectrometer for size distribution measurement of solution metered dose inhalers. J. Aerosol Med. 2003, 16 (2), 107-119.
    • (2003) J. Aerosol Med. , vol.16 , Issue.2 , pp. 107-119
    • Stein, S.W.1    Myrdal, P.E.2    Gabrio, B.J.3    Obereit, D.4    Beck, T.J.5
  • 5
    • 5444275286 scopus 로고    scopus 로고
    • Proceedings of Respiratory Drug Delivery VII, Tarpon Springs, Florida, May 14-18, 2000; Byron, P.R., Dalby, R.N., Farr, S.J., Peart, J., Eds.; Serentec Press: Raleigh, NC
    • Stein, S.W.; Beck, T.J.; Gabrio, B.J. In Evaluation of a New Aerodynamic Particle Sizer Spectrometer for MDI Size Distribution Measurements, Proceedings of Respiratory Drug Delivery VII, Tarpon Springs, Florida, May 14-18, 2000; Byron, P.R., Dalby, R.N., Farr, S.J., Peart, J., Eds.; Serentec Press: Raleigh, NC, 2000; 283-286.
    • (2000) Evaluation of a New Aerodynamic Particle Sizer Spectrometer for MDI Size Distribution Measurements , pp. 283-286
    • Stein, S.W.1    Beck, T.J.2    Gabrio, B.J.3
  • 7
    • 5444263337 scopus 로고    scopus 로고
    • Proceedings of Respiratory Drug Delivery VII, Tarpon Springs, Florida, May 14-18, 2000; Byron, P.R., Dalby, R.N., Farr, S.J., Peart, J., Eds.; Serentec Press: Raleigh, NC
    • Stein, S.W.; Gabrio, B.J. In Understanding Throat Deposition During Cascade Impaction Testing, Proceedings of Respiratory Drug Delivery VII, Tarpon Springs, Florida, May 14-18, 2000; Byron, P.R., Dalby, R.N., Farr, S.J., Peart, J., Eds.; Serentec Press: Raleigh, NC, 2000; 287-290.
    • (2000) Understanding Throat Deposition during Cascade Impaction Testing , pp. 287-290
    • Stein, S.W.1    Gabrio, B.J.2
  • 9
    • 5444272491 scopus 로고    scopus 로고
    • TSI Incorporated Particle Instruments: St. Paul, MN
    • TSI Incorporated Particle Instruments. Model 3306 Impactor Inlet Operating Manual; TSI Incorporated Particle Instruments: St. Paul, MN, 2003.
    • (2003) Model 3306 Impactor Inlet Operating Manual
  • 10
    • 0024867672 scopus 로고
    • The Andersen Impactor: Calibration, wall losses and numerical simulation
    • Vaughan, N.P. The Andersen Impactor: calibration, wall losses and numerical simulation. J. Aerosol Sci. 1989, 20 (1), 67-90.
    • (1989) J. Aerosol Sci. , vol.20 , Issue.1 , pp. 67-90
    • Vaughan, N.P.1
  • 11
    • 0023994394 scopus 로고
    • An assessment of Andersen Mark-II cascade impactor
    • Mitchell, J.P.; Costa, P.A.; Waters, S. An assessment of Andersen Mark-II cascade impactor. J. Aerosol Sci. 1988, 19 (2), 213-221.
    • (1988) J. Aerosol Sci. , vol.19 , Issue.2 , pp. 213-221
    • Mitchell, J.P.1    Costa, P.A.2    Waters, S.3
  • 12
    • 0032790249 scopus 로고    scopus 로고
    • Size distribution measurements of metered dose inhalers using Andersen Mark II cascade impactors
    • Stein, S.W. Size distribution measurements of metered dose inhalers using Andersen Mark II cascade impactors. Int. J. Pharm. 1999, 186, 43-52.
    • (1999) Int. J. Pharm. , vol.186 , pp. 43-52
    • Stein, S.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.