메뉴 건너뛰기




Volumn 37, Issue 4, 2005, Pages 204-209

Development of a special balloon occlusion device to prevent adverse events in high-risk patients during open aortic surgery

Author keywords

Atherosclerosis; Cross clamping; Intraluminal balloon occlusion; Porcelain aorta

Indexed keywords

ANIMAL TISSUE; AORTA ANEURYSM; AORTA SURGERY; ARTICLE; ATHEROSCLEROSIS; BALLOON OCCLUSION; DEVICE; DISEASE SEVERITY; HIGH RISK PATIENT; HISTOLOGY; LABORATORY TEST; NONHUMAN; PRIORITY JOURNAL; SWINE; VASCULAR SURGERY;

EID: 27544509895     PISSN: 0014312X     EISSN: None     Source Type: Journal    
DOI: 10.1159/000087864     Document Type: Article
Times cited : (4)

References (17)
  • 2
    • 0022642223 scopus 로고
    • Aortic valve replacement in a patient with extensive calcification of the ascending aorta (the porcelain aorta)
    • Coselli JS, Crawford ES: Aortic valve replacement in a patient with extensive calcification of the ascending aorta (the porcelain aorta). J Thorac Cardiovasc Surg 1986;91:184-187.
    • (1986) J Thorac Cardiovasc Surg , vol.91 , pp. 184-187
    • Coselli, J.S.1    Crawford, E.S.2
  • 3
    • 0025947943 scopus 로고
    • Atherosclerosis of the ascending aorta and coronary bypass. Pathology, clinical correlates, and operative management
    • Mills NL, Everson CT: Atherosclerosis of the ascending aorta and coronary bypass. Pathology, clinical correlates, and operative management. J Thorac Cardiovasc Surg 1991;102:546-553.
    • (1991) J Thorac Cardiovasc Surg , vol.102 , pp. 546-553
    • Mills, N.L.1    Everson, C.T.2
  • 4
    • 0033004528 scopus 로고    scopus 로고
    • Management of porcelain aorta during coronary artery bypass grafting
    • Leyh RG, Bartels C, Noetzold A, Sievers HH: Management of porcelain aorta during coronary artery bypass grafting. Ann Thorac Surg 1999;67:986-988.
    • (1999) Ann Thorac Surg , vol.67 , pp. 986-988
    • Leyh, R.G.1    Bartels, C.2    Noetzold, A.3    Sievers, H.H.4
  • 5
    • 0001345012 scopus 로고
    • Intraluminal aortic occlusion as a possible mechanism for controlling massive intraabdominal hemorrhage
    • Edwards WS, Salter PP Jr, Carnaggio VA: Intraluminal aortic occlusion as a possible mechanism for controlling massive intraabdominal hemorrhage. Surg Forum 1953;4:496-499.
    • (1953) Surg Forum , vol.4 , pp. 496-499
    • Edwards, W.S.1    Salter Jr., P.P.2    Carnaggio, V.A.3
  • 6
    • 0017580878 scopus 로고
    • Endothelial changes secondary to use of a Fogarty catheter
    • Dujovny M, Laha RK, Barrionuevo P: Endothelial changes secondary to use of a Fogarty catheter. Surg Neurol 1977;7:39-41.
    • (1977) Surg Neurol , vol.7 , pp. 39-41
    • Dujovny, M.1    Laha, R.K.2    Barrionuevo, P.3
  • 7
    • 0014784167 scopus 로고
    • Intra-arterial occlusion in vascular surgery
    • McCaughan JJ, Young JM: Intra-arterial occlusion in vascular surgery. Ann Surg 1970;171:695-703.
    • (1970) Ann Surg , vol.171 , pp. 695-703
    • McCaughan, J.J.1    Young, J.M.2
  • 8
    • 2542420911 scopus 로고    scopus 로고
    • Balloon occlusion of calcified aortic aneurysm with aortic insufficiency
    • Walts PA, Lee R, Gillinov AM: Balloon occlusion of calcified aortic aneurysm with aortic insufficiency. J Card Surg 2004;19:279-280.
    • (2004) J Card Surg , vol.19 , pp. 279-280
    • Walts, P.A.1    Lee, R.2    Gillinov, A.M.3
  • 9
    • 0026786098 scopus 로고
    • Clamping of the atherosclerotic ascending aorta during coronary artery bypass operations
    • Bar-El Y, Goor D: Clamping of the atherosclerotic ascending aorta during coronary artery bypass operations. J Thorac Cardiovasc Surg 1992;104:469-473.
    • (1992) J Thorac Cardiovasc Surg , vol.104 , pp. 469-473
    • Bar-El, Y.1    Goor, D.2
  • 11
    • 0842308162 scopus 로고    scopus 로고
    • The use of an aortic connector system in a patient with severe calcified ascending aorta
    • Gummert JF, Bossert T, Mohr FW: The use of an aortic connector system in a patient with severe calcified ascending aorta. J Card Surg 2004;19:62-64.
    • (2004) J Card Surg , vol.19 , pp. 62-64
    • Gummert, J.F.1    Bossert, T.2    Mohr, F.W.3
  • 12
    • 0034837488 scopus 로고    scopus 로고
    • Use of the intra-aortic balloon pump to stop gastrointestinal bleeding
    • Karkos CD, Bruce IA, Lambert ME: Use of the intra-aortic balloon pump to stop gastrointestinal bleeding. Ann Emerg Med 2001;38:328-331.
    • (2001) Ann Emerg Med , vol.38 , pp. 328-331
    • Karkos, C.D.1    Bruce, I.A.2    Lambert, M.E.3
  • 14
    • 0036587265 scopus 로고    scopus 로고
    • Aortic occlusion catheter with perfusion lumen for protection of lower body during distal anastomosis in aortic arch repair
    • Takagi H, Mori Y, Iwata H, Umeda Y, Matsuno Y, Hirose H: Aortic occlusion catheter with perfusion lumen for protection of lower body during distal anastomosis in aortic arch repair. J Thorac Cardiovasc Surg 2002;123:1006-1008.
    • (2002) J Thorac Cardiovasc Surg , vol.123 , pp. 1006-1008
    • Takagi, H.1    Mori, Y.2    Iwata, H.3    Umeda, Y.4    Matsuno, Y.5    Hirose, H.6
  • 15
    • 1642441513 scopus 로고    scopus 로고
    • Transfemoral control of ruptured aortic pseudoaneurysm at aortic root reoperation
    • Pettersson G, Nores M, Gillinov AM: Transfemoral control of ruptured aortic pseudoaneurysm at aortic root reoperation. Ann Thorac Surg 2004;77:311-312.
    • (2004) Ann Thorac Surg , vol.77 , pp. 311-312
    • Pettersson, G.1    Nores, M.2    Gillinov, A.M.3
  • 16
    • 0345167818 scopus 로고    scopus 로고
    • Transbrachial arterial insertion of aortic occlusion balloon catheter in patients with shock from ruptured abdominal aortic aneurysm
    • Matsuda H, Tanaka Y, Hino Y, Matsukawa R, Ozaki N, Okada K, Tsukube T, Tsuji Y, Okita Y: Transbrachial arterial insertion of aortic occlusion balloon catheter in patients with shock from ruptured abdominal aortic aneurysm. J Vasc Surg 2003;1293-1296.
    • (2003) J Vasc Surg , pp. 1293-1296
    • Matsuda, H.1    Tanaka, Y.2    Hino, Y.3    Matsukawa, R.4    Ozaki, N.5    Okada, K.6    Tsukube, T.7    Tsuji, Y.8    Okita, Y.9
  • 17
    • 0017360237 scopus 로고
    • Use of Fogarty catheter tamponade for ruptured abdominal aortic aneurysms
    • Ng AC, Ochsner EC: Use of Fogarty catheter tamponade for ruptured abdominal aortic aneurysms. Am J Roentgenol 1977;128:31-33.
    • (1977) Am J Roentgenol , vol.128 , pp. 31-33
    • Ng, A.C.1    Ochsner, E.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.