메뉴 건너뛰기




Volumn 27, Issue 5, 2005, Pages 219-226

Registration of confocal scanning laser microscopy and quantitative backscattered electron images for the temporospatial quantification of mineralization density in 18-month old thoroughbred racehorse articular calcified cartilage

Author keywords

Articular calcified cartilage; Confocal scanning laser microscopy; Equine; Image registration; Quantitative backscattered electron scanning electron microscopy

Indexed keywords

ELECTRONS; HISTOLOGY; MUSCLE; PARAMETER ESTIMATION; SCANNING ELECTRON MICROSCOPY;

EID: 27344453702     PISSN: 01610457     EISSN: None     Source Type: Journal    
DOI: 10.1002/sca.4950270502     Document Type: Article
Times cited : (8)

References (28)
  • 1
    • 0042066398 scopus 로고    scopus 로고
    • The real response of bone to exercise
    • Boyde A: The real response of bone to exercise. J Anat 203, 2, 173-189 (2003)
    • (2003) J Anat , vol.203 , Issue.2 , pp. 173-189
    • Boyde, A.1
  • 2
    • 12344261420 scopus 로고    scopus 로고
    • Articular calcified cartilage canals in the third metacarpal bone of 2-year old thoroughbred racehorses
    • Boyde A, Firth EC: Articular calcified cartilage canals in the third metacarpal bone of 2-year old thoroughbred racehorses. J Anat 205, 6, 491-500 (2004)
    • (2004) J Anat , vol.205 , Issue.6 , pp. 491-500
    • Boyde, A.1    Firth, E.C.2
  • 3
    • 6344279052 scopus 로고    scopus 로고
    • Musculoskeletal responses of 2-year old Thoroughbred horses to early training. 8. Quantitative back-scattered electron scanning electron microscopy and confocal fluorescence microscopy of the epiphysis of the third metacarpal bone
    • Boyde A, Firth EC: Musculoskeletal responses of 2-year old Thoroughbred horses to early training. 8. Quantitative back-scattered electron scanning electron microscopy and confocal fluorescence microscopy of the epiphysis of the third metacarpal bone. New Zealand Vet J 2, 53, 123-132 (2005)
    • (2005) New Zealand Vet J , vol.2 , Issue.53 , pp. 123-132
    • Boyde, A.1    Firth, E.C.2
  • 4
    • 0027243689 scopus 로고
    • Stereology and histogram analysis of backscattered electron images: Age changes in bone
    • Boyde A, Elliott JC, Jones SJ: Stereology and histogram analysis of backscattered electron images: Age changes in bone. Bone 14, 205-210 (1993)
    • (1993) Bone , vol.14 , pp. 205-210
    • Boyde, A.1    Elliott, J.C.2    Jones, S.J.3
  • 5
    • 22444445899 scopus 로고    scopus 로고
    • Combining confocal and BSE SEM imaging for bone block surfaces
    • Apr. 26
    • Boyde A, Lovicar L, Zamecnik J: Combining confocal and BSE SEM imaging for bone block surfaces. Eur Cells Mat 9, Apr. 26, 33-38 (2005)
    • (2005) Eur Cells Mat , vol.9 , pp. 33-38
    • Boyde, A.1    Lovicar, L.2    Zamecnik, J.3
  • 6
    • 0010603622 scopus 로고
    • Stereology of bone using both backscattered electron and cathodoluminescence imaging for the SEM
    • Boyde A, Reid SA, Howell PGT: Stereology of bone using both backscattered electron and cathodoluminescence imaging for the SEM. Beitr Elektronenmikroskop Direktabb Oberfl 16, 419-430 (1983)
    • (1983) Beitr Elektronenmikroskop Direktabb Oberfl , vol.16 , pp. 419-430
    • Boyde, A.1    Reid, S.A.2    Howell, P.G.T.3
  • 8
    • 0041565072 scopus 로고    scopus 로고
    • Nanomechanical properties and mineral concentration in articular calcified cartilage and subchondral bone
    • Ferguson VL, Bushby AJ, Boyde A: Nanomechanical properties and mineral concentration in articular calcified cartilage and subchondral bone. J Anat 203, 2, 191-202 (2003)
    • (2003) J Anat , vol.203 , Issue.2 , pp. 191-202
    • Ferguson, V.L.1    Bushby, A.J.2    Boyde, A.3
  • 9
    • 0008877610 scopus 로고
    • Tetracycline labeling and the zone of demarcation of osteoid seams
    • Frost HM: Tetracycline labeling and the zone of demarcation of osteoid seams. Can J Biochem Phys 40, 485-489 (1962)
    • (1962) Can J Biochem Phys , vol.40 , pp. 485-489
    • Frost, H.M.1
  • 10
    • 0034487998 scopus 로고    scopus 로고
    • Correlative light and backscattered electron microscopy of bone-part II: Automated image analysis
    • Goldman HM, Blayvas A, Boyde A, Howell PG, Clement JG, Bromage TG: Correlative light and backscattered electron microscopy of bone-part II: automated image analysis. Scanning 22, 6, 337-344 (2000)
    • (2000) Scanning , vol.22 , Issue.6 , pp. 337-344
    • Goldman, H.M.1    Blayvas, A.2    Boyde, A.3    Howell, P.G.4    Clement, J.G.5    Bromage, T.G.6
  • 11
    • 0027980354 scopus 로고
    • Correlated alkaline-phosphatase histochemistry and quantitative backscattered electron imaging in the study of rat incisor ameloblasts and enamel mineralization
    • Gomez S, Boyde A: Correlated alkaline-phosphatase histochemistry and quantitative backscattered electron imaging in the study of rat incisor ameloblasts and enamel mineralization. Microsc Res Tech 29, 1, 29-36 (1994)
    • (1994) Microsc Res Tech , vol.29 , Issue.1 , pp. 29-36
    • Gomez, S.1    Boyde, A.2
  • 13
    • 84984051904 scopus 로고
    • A microcomputer-based system for rapid on-line stereological analysis in the scanning electron microscope
    • Howell PGT, Reid SA: A microcomputer-based system for rapid on-line stereological analysis in the scanning electron microscope. Scanning 8, 139-144 (1986)
    • (1986) Scanning , vol.8 , pp. 139-144
    • Howell, P.G.T.1    Reid, S.A.2
  • 14
    • 0031815870 scopus 로고    scopus 로고
    • Mean atomic number and backscattered electron coefficient calculations for some materials with low mean atomic number
    • Howell PGT, Davy KMW, Boyde A: Mean atomic number and backscattered electron coefficient calculations for some materials with low mean atomic number. Scanning 20, 1, 35-40 (1998)
    • (1998) Scanning , vol.20 , Issue.1 , pp. 35-40
    • Howell, P.G.T.1    Davy, K.M.W.2    Boyde, A.3
  • 15
    • 0033388022 scopus 로고    scopus 로고
    • Surface roughness of preparations for backscattered electron-scanning electron microscopy: The image differences and their Monte Carlo simulation
    • Howell PGT, Boyde A: Surface roughness of preparations for backscattered electron-scanning electron microscopy: The image differences and their Monte Carlo simulation. Scanning 21, 6, 361-367 (1999)
    • (1999) Scanning , vol.21 , Issue.6 , pp. 361-367
    • Howell, P.G.T.1    Boyde, A.2
  • 16
    • 0001943161 scopus 로고
    • Foundations of confocal scanned imaging in light microscopy
    • (Ed. Pawley JB). Plenum Press, New York
    • Inoué S: Foundations of confocal scanned imaging in light microscopy. In Handbook of Biological Confocal Microscopy (Ed. Pawley JB). Plenum Press, New York (1995) 1-17
    • (1995) Handbook of Biological Confocal Microscopy , pp. 1-17
    • Inoué, S.1
  • 17
    • 5344266050 scopus 로고    scopus 로고
    • Bone mineralization density and femoral neck fragility
    • Loveridge N, Power J, Reeve J, Boy de A: Bone mineralization density and femoral neck fragility. Bone 35, 4, 929-941 (2004)
    • (2004) Bone , vol.35 , Issue.4 , pp. 929-941
    • Loveridge, N.1    Power, J.2    Reeve, J.3    De Boy, A.4
  • 20
    • 27344436468 scopus 로고    scopus 로고
    • United States National Institutes of Health
    • Rasband W: ImageJ. v1.34i United States National Institutes of Health, http://rsb.info.nih.gov/ij/(2005)
    • (2005) ImageJ. v1.34i
    • Rasband, W.1
  • 21
    • 0023286472 scopus 로고
    • Changes in the mineral density distribution in human bone with age: Image analysis using backscattered electrons in SEM
    • Reid SA, Boyde A: Changes in the mineral density distribution in human bone with age: Image analysis using backscattered electrons in SEM. J Bone Min Res 2, 13-22 (1987)
    • (1987) J Bone Min Res , vol.2 , pp. 13-22
    • Reid, S.A.1    Boyde, A.2
  • 22
    • 0033094706 scopus 로고    scopus 로고
    • Aetiopathogenesis of parasagittal fractures of the distal condyles of the third metacarpal and third metatarsal bones-review of the literature
    • Riggs CM: Aetiopathogenesis of parasagittal fractures of the distal condyles of the third metacarpal and third metatarsal bones-review of the literature. Equine Vet J 31, 2, 116-120 (1999)
    • (1999) Equine Vet J , vol.31 , Issue.2 , pp. 116-120
    • Riggs, C.M.1
  • 23
    • 0033091772 scopus 로고    scopus 로고
    • Pathology of the distal condyles of the third metacarpal and third metatarsal bones of the horse
    • Riggs CM, Whitehouse GH, Boyde A: Pathology of the distal condyles of the third metacarpal and third metatarsal bones of the horse. Equine Vet J 31, 2, 140-148 (1999)
    • (1999) Equine Vet J , vol.31 , Issue.2 , pp. 140-148
    • Riggs, C.M.1    Whitehouse, G.H.2    Boyde, A.3
  • 24
    • 17644445505 scopus 로고    scopus 로고
    • Validation of quantitative backscattered electron imaging for the measurement of mineral density distribution in human bone biopsies
    • Roschger P, Fratzl P, Eschberger J, Klaushofer K: Validation of quantitative backscattered electron imaging for the measurement of mineral density distribution in human bone biopsies. Bone 23, 4, 319-326 (1998)
    • (1998) Bone , vol.23 , Issue.4 , pp. 319-326
    • Roschger, P.1    Fratzl, P.2    Eschberger, J.3    Klaushofer, K.4
  • 25
    • 0029592232 scopus 로고
    • Consistency in calibrated backscattered electron images of calcified tissues and minerals analyzed in multiple imaging dessions
    • Vajda EG, Skedros JG, Bloebaum RD: Consistency in calibrated backscattered electron images of calcified tissues and minerals analyzed in multiple imaging dessions. Scan Microsc 9, 3, 741-755 (1995)
    • (1995) Scan Microsc , vol.9 , Issue.3 , pp. 741-755
    • Vajda, E.G.1    Skedros, J.G.2    Bloebaum, R.D.3
  • 26
    • 2542640979 scopus 로고    scopus 로고
    • Descriptive epidemiology of fractures occurring in British Thoroughbred racehorses in training
    • Verheyen KL, Wood JL: Descriptive epidemiology of fractures occurring in British Thoroughbred racehorses in training. Equine Vet J 36, 2, 167-173 (2004)
    • (2004) Equine Vet J , vol.36 , Issue.2 , pp. 167-173
    • Verheyen, K.L.1    Wood, J.L.2
  • 27
    • 27344442734 scopus 로고    scopus 로고
    • United States National Institutes of Health
    • Walter J: Sync Windows. United States National Institutes of Health, http://rsb.info.nih.gov/ij7plugins/sync-windows.html (2004)
    • (2004) Sync Windows
    • Walter, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.