메뉴 건너뛰기




Volumn 89, Issue 11, 2005, Pages 1389-1390

Risk factors for posterior capsule opacification

Author keywords

[No Author keywords available]

Indexed keywords

BIOMECHANICS; CAPSULORHEXIS; CAPSULOTOMY; CATARACT; CATARACT EXTRACTION; EDITORIAL; HUMAN; NEODYMIUM LASER; PRIORITY JOURNAL; RETINA DETACHMENT; RETINA MACULA CYSTOID EDEMA; RISK ASSESSMENT; RISK FACTOR;

EID: 27344451140     PISSN: 00071161     EISSN: None     Source Type: Journal    
DOI: 10.1136/bjo.2005.074310     Document Type: Editorial
Times cited : (5)

References (10)
  • 1
    • 0035115046 scopus 로고    scopus 로고
    • Eradication of posterior capsule opacification. Documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained post mortem
    • Apple DJ, Peng Q, Visessook, et al. Eradication of posterior capsule opacification. Documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained post mortem. Ophthalmology 2001;108:18.
    • (2001) Ophthalmology , vol.108 , pp. 18
    • Apple, D.J.1    Peng, Q.2    Visessook3
  • 2
    • 16344365705 scopus 로고    scopus 로고
    • Effect of 1-piece and 3-plece AcrySof intraocular lenses on the development of posterior capsule opacification after cataract surgery
    • Bender L, Nimsgern C, Jose R, et al. Effect of 1-piece and 3-plece AcrySof intraocular lenses on the development of posterior capsule opacification after cataract surgery. J Cataract Refract Surg 2004;30:786-9.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 786-789
    • Bender, L.1    Nimsgern, C.2    Jose, R.3
  • 3
    • 2642514832 scopus 로고    scopus 로고
    • A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses
    • Nejima R, Miyata K, Honbou M. A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses. Br J Ophthalmol 2004;88:746-9.
    • (2004) Br J Ophthalmol , vol.88 , pp. 746-749
    • Nejima, R.1    Miyata, K.2    Honbou, M.3
  • 4
    • 4744362768 scopus 로고    scopus 로고
    • Comparison of posterior capsule opacification between the 1-piece and 3-piece Acrysof intraocular lenses. Two year results of a randomized trial
    • Sacu S, Findl O, Menapace R, et al. Comparison of posterior capsule opacification between the 1-piece and 3-piece Acrysof intraocular lenses. Two year results of a randomized trial. Ophthalmology 2004;111:1840-6.
    • (2004) Ophthalmology , vol.111 , pp. 1840-1846
    • Sacu, S.1    Findl, O.2    Menapace, R.3
  • 5
    • 0141458945 scopus 로고    scopus 로고
    • A clinical comparison of single-piece and three piece truncated hydrophobic acrylic intraocular lenses
    • Wallin TR, Hinkley M, Nilson C, et al. A clinical comparison of single-piece and three piece truncated hydrophobic acrylic intraocular lenses. Am J Ophthalmol 2003;136:614-19.
    • (2003) Am J Ophthalmol , vol.136 , pp. 614-619
    • Wallin, T.R.1    Hinkley, M.2    Nilson, C.3
  • 6
    • 0036784454 scopus 로고    scopus 로고
    • Systems of analysis of posterior capsule opacification
    • Aslam TM, Dhillon B, Werqhi N, et al. Systems of analysis of posterior capsule opacification. Br J Ophthalmol 2002;86:1181-6.
    • (2002) Br J Ophthalmol , vol.86 , pp. 1181-1186
    • Aslam, T.M.1    Dhillon, B.2    Werqhi, N.3
  • 7
    • 7044234855 scopus 로고    scopus 로고
    • Limitation of Scheimpflug videophotography system in quantifying posterior capsule opacification after intraocular lens implantation
    • Hayashi K, Hayashi H. Limitation of Scheimpflug videophotography system in quantifying posterior capsule opacification after intraocular lens implantation. Am J Ophthalmol 2004;138:696.
    • (2004) Am J Ophthalmol , vol.138 , pp. 696
    • Hayashi, K.1    Hayashi, H.2
  • 8
    • 22144477955 scopus 로고    scopus 로고
    • A freely accessible, evidence based, objective system of analysis of posterior capsular opacification; evidence for its validity and reliability
    • Aslam TM, Patton N, Graham J. A freely accessible, evidence based, objective system of analysis of posterior capsular opacification; evidence for its validity and reliability. BMC Ophthalmol 2005;5:9.
    • (2005) BMC Ophthalmol , vol.5 , pp. 9
    • Aslam, T.M.1    Patton, N.2    Graham, J.3
  • 9
    • 7044237144 scopus 로고    scopus 로고
    • Posterior capsule opacification and YAG capsulotomy
    • Lane SS. Posterior capsule opacification and YAG capsulotomy. Am J Ophthalmol 2004;138:635-6.
    • (2004) Am J Ophthalmol , vol.138 , pp. 635-636
    • Lane, S.S.1
  • 10
    • 7044220481 scopus 로고    scopus 로고
    • The effect of lens edge design versus anterior capsule overlap on posterior capsule opacification
    • Smith SR, Daynes T, Hinckley M, et al. The effect of lens edge design versus anterior capsule overlap on posterior capsule opacification. Am J Ophthalmol 2004;138:521-6.
    • (2004) Am J Ophthalmol , vol.138 , pp. 521-526
    • Smith, S.R.1    Daynes, T.2    Hinckley, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.