메뉴 건너뛰기




Volumn 111, Issue 10, 2004, Pages 1840-1846

Comparison of posterior capsule opacification between the 1-piece and 3-piece Acrysof intraocular lenses: Two-year results of a randomized trial

Author keywords

[No Author keywords available]

Indexed keywords

ALUMINUM; NEODYMIUM; YTTRIUM;

EID: 4744362768     PISSN: 01616420     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ophtha.2004.03.028     Document Type: Article
Times cited : (46)

References (29)
  • 1
    • 0030910047 scopus 로고    scopus 로고
    • Intraocular pressure change after neodymium: YAG capsulotomy
    • Holweger R.R., Marefat B. Intraocular pressure change after neodymium YAG capsulotomy. J Cataract Refract Surg. 23:1997;115-121
    • (1997) J Cataract Refract Surg , vol.23 , pp. 115-121
    • Holweger, R.R.1    Marefat, B.2
  • 2
    • 0032951997 scopus 로고    scopus 로고
    • Experimental neodymium: YAG laser damage to acrylic, poly(methyl methacrylate), and silicone intraocular lens materials
    • Newland T.J., McDermott M.L., Eliott D., et al. Experimental neodymium YAG laser damage to acrylic, poly(methyl methacrylate), and silicone intraocular lens materials. J Cataract Refract Surg. 25:1999;72-76
    • (1999) J Cataract Refract Surg , vol.25 , pp. 72-76
    • Newland, T.J.1    McDermott, M.L.2    Eliott, D.3
  • 3
    • 0026052333 scopus 로고
    • Cystoid macular edema, retinal detachment, and glaucoma after Nd: YAG laser posterior capsulotomy
    • Steinert R.F., Puliafito C.A., Kumar S.R., et al. Cystoid macular edema, retinal detachment, and glaucoma after Nd YAG laser posterior capsulotomy. Am J Ophthalmol. 112:1991;373-380
    • (1991) Am J Ophthalmol , vol.112 , pp. 373-380
    • Steinert, R.F.1    Puliafito, C.A.2    Kumar, S.R.3
  • 5
    • 0033497365 scopus 로고    scopus 로고
    • Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II: Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification
    • Ram J., Apple D.J., Peng Q., et al. Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification. Ophthalmology. 106:1999;891-900
    • (1999) Ophthalmology , vol.106 , pp. 891-900
    • Ram, J.1    Apple, D.J.2    Peng, Q.3
  • 6
    • 0032895795 scopus 로고    scopus 로고
    • Posterior capsule opacification. Part 1: Experimental investigations
    • Nishi O. Posterior capsule opacification. Part 1 experimental investigations. J Cataract Refract Surg. 25:1999;106-117
    • (1999) J Cataract Refract Surg , vol.25 , pp. 106-117
    • Nishi, O.1
  • 7
    • 0031817140 scopus 로고    scopus 로고
    • Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens
    • Nishi O., Nishi K., Sakanishi K. Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens. Ophthalmic Surg Lasers. 29:1998;587-594
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 587-594
    • Nishi, O.1    Nishi, K.2    Sakanishi, K.3
  • 8
    • 0034911128 scopus 로고    scopus 로고
    • Sharp-edged intraocular lens design as a cause of permanent glare
    • Ellis M.F. Sharp-edged intraocular lens design as a cause of permanent glare. J Cataract Refract Surg. 27:2001;1061-1064
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1061-1064
    • Ellis, M.F.1
  • 9
    • 0033055918 scopus 로고    scopus 로고
    • Analysis of edge glare phenomena in intraocular lens edge designs
    • Holladay J.T., Lang A., Portney V. Analysis of edge glare phenomena in intraocular lens edge designs. J Cataract Refract Surg. 25:1999;748-752
    • (1999) J Cataract Refract Surg , vol.25 , pp. 748-752
    • Holladay, J.T.1    Lang, A.2    Portney, V.3
  • 10
    • 0036822444 scopus 로고    scopus 로고
    • The effect of texturing the intraocular lens edge on postoperative glare symptoms: A randomized, prospective, double-masked study
    • Meacock W.R., Spalton D.J., Khan S. The effect of texturing the intraocular lens edge on postoperative glare symptoms a randomized, prospective, double-masked study. Arch Ophthalmol. 120:2002;1294-1298
    • (2002) Arch Ophthalmol , vol.120 , pp. 1294-1298
    • Meacock, W.R.1    Spalton, D.J.2    Khan, S.3
  • 11
    • 0033927053 scopus 로고    scopus 로고
    • Dysphotopsia in phakic and pseudophakic patients: Incidence and relation to intraocular lens type
    • Tester R., Pace N.L., Samore M., Olson R.J. Dysphotopsia in phakic and pseudophakic patients incidence and relation to intraocular lens type. J Cataract Refract Surg. 26:2000;810-816
    • (2000) J Cataract Refract Surg , vol.26 , pp. 810-816
    • Tester, R.1    Pace, N.L.2    Samore, M.3    Olson, R.J.4
  • 12
    • 0031456846 scopus 로고    scopus 로고
    • High-resolution digital retroillumination imaging of the posterior capsule after cataract surgery
    • Pande M.V., Ursell P.G., Spalton D.J., et al. High-resolution digital retroillumination imaging of the posterior capsule after cataract surgery. J Cataract Refract Surg. 23:1997;1521-1527
    • (1997) J Cataract Refract Surg , vol.23 , pp. 1521-1527
    • Pande, M.V.1    Ursell, P.G.2    Spalton, D.J.3
  • 13
    • 0036062059 scopus 로고    scopus 로고
    • Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification
    • Buehl W., Findl O., Menapace R., et al. Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 28:2002;1105-1111
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1105-1111
    • Buehl, W.1    Findl, O.2    Menapace, R.3
  • 14
    • 0036169815 scopus 로고    scopus 로고
    • Assessment of anterior capsule opacification: Photographic technique and quantification
    • Sacu S., Findl O., Menapace R., et al. Assessment of anterior capsule opacification photographic technique and quantification. J Cataract Refract Surg. 28:2002;271-275
    • (2002) J Cataract Refract Surg , vol.28 , pp. 271-275
    • Sacu, S.1    Findl, O.2    Menapace, R.3
  • 17
    • 0030793930 scopus 로고    scopus 로고
    • Proper method for calculating average visual acuity
    • Holladay J.T. Proper method for calculating average visual acuity. J Refract Surg. 13:1997;388-391
    • (1997) J Refract Surg , vol.13 , pp. 388-391
    • Holladay, J.T.1
  • 19
    • 0037257792 scopus 로고    scopus 로고
    • Comparison of 4 methods for quantifying posterior capsule opacification
    • Findl O., Buehl W., Menapace R., et al. Comparison of 4 methods for quantifying posterior capsule opacification. J Cataract Refract Surg. 29:2003;106-111
    • (2003) J Cataract Refract Surg , vol.29 , pp. 106-111
    • Findl, O.1    Buehl, W.2    Menapace, R.3
  • 20
    • 0031890039 scopus 로고    scopus 로고
    • The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring
    • Nishi O., Nishi K., Mano C., et al. The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring. Ophthalmic Surg Lasers. 29:1998;119-125
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 119-125
    • Nishi, O.1    Nishi, K.2    Mano, C.3
  • 21
    • 0033968119 scopus 로고    scopus 로고
    • Surgical prevention of posterior capsule opacification. Part 3: Intraocular lens optic barrier effect as a second line of defense
    • Peng Q., Visessook N., Apple D.J., et al. Surgical prevention of posterior capsule opacification. Part 3 intraocular lens optic barrier effect as a second line of defense. J Cataract Refract Surg. 26:2000;198-213
    • (2000) J Cataract Refract Surg , vol.26 , pp. 198-213
    • Peng, Q.1    Visessook, N.2    Apple, D.J.3
  • 22
    • 0033772907 scopus 로고    scopus 로고
    • Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges
    • Nishi O., Nishi K., Wickstrom K. Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges. J Cataract Refract Surg. 26:2000;1543-1549
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1543-1549
    • Nishi, O.1    Nishi, K.2    Wickstrom, K.3
  • 23
    • 0028935499 scopus 로고
    • Postoperative membranous proliferation from the anterior capsulotomy margin onto the intraocular lens optic
    • Nagamoto T., Hara E. Postoperative membranous proliferation from the anterior capsulotomy margin onto the intraocular lens optic. J Cataract Refract Surg. 21:1995;208-211
    • (1995) J Cataract Refract Surg , vol.21 , pp. 208-211
    • Nagamoto, T.1    Hara, E.2
  • 24
    • 0032692941 scopus 로고    scopus 로고
    • Adhesion of soluble fibronectin, laminin, and collagen type IV to intraocular lens materials
    • Linnola R.J., Sund M., Ylonen R., Pihlajaniemi T. Adhesion of soluble fibronectin, laminin, and collagen type IV to intraocular lens materials. J Cataract Refract Surg. 25:1999;1486-1491
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1486-1491
    • Linnola, R.J.1    Sund, M.2    Ylonen, R.3    Pihlajaniemi, T.4
  • 25
    • 0034535473 scopus 로고    scopus 로고
    • Adhesion of fibronectin, vitronectin, laminin, and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyes. Part 1: Histological sections
    • Linnola R.J., Werner L., Pandey S.K., et al. Adhesion of fibronectin, vitronectin, laminin, and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyes. Part 1 histological sections. J Cataract Refract Surg. 26:2000;1792-1806
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1792-1806
    • Linnola, R.J.1    Werner, L.2    Pandey, S.K.3
  • 26
    • 0141458945 scopus 로고    scopus 로고
    • A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lenses
    • Wallin T.R., Hinckley M., Nilson C., Olson R.J. A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lenses. Am J Ophthalmol. 136:2003;614-619
    • (2003) Am J Ophthalmol , vol.136 , pp. 614-619
    • Wallin, T.R.1    Hinckley, M.2    Nilson, C.3    Olson, R.J.4
  • 27
    • 0034892704 scopus 로고    scopus 로고
    • Effect of optic size on posterior capsule opacification: 5.5 mm versus 6.0 mm AcrySof intraocular lenses
    • Meacock W.R., Spalton D.J., Boyce J.F., Jose R.M. Effect of optic size on posterior capsule opacification 5.5 mm versus 6.0 mm AcrySof intraocular lenses. J Cataract Refract Surg. 27:2001;1194-1198
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1194-1198
    • Meacock, W.R.1    Spalton, D.J.2    Boyce, J.F.3    Jose, R.M.4
  • 28
    • 0036068597 scopus 로고    scopus 로고
    • Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge
    • Schmidbauer J.M., Escobar-Gomez M., Apple D.J., et al. Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge. J Cataract Refract Surg. 28:2002;1251-1255
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1251-1255
    • Schmidbauer, J.M.1    Escobar-Gomez, M.2    Apple, D.J.3
  • 29
    • 0031955031 scopus 로고    scopus 로고
    • Comparison of decentration and tilt between one piece and three piece polymethyl methacrylate intraocular lenses
    • Hayashi K., Hayashi H., Nakao F., Hayashi F. Comparison of decentration and tilt between one piece and three piece polymethyl methacrylate intraocular lenses. Br J Ophthalmol. 82:1998;419-422
    • (1998) Br J Ophthalmol , vol.82 , pp. 419-422
    • Hayashi, K.1    Hayashi, H.2    Nakao, F.3    Hayashi, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.