Volumn 32, Issue 11, 2005, Pages 838-843

Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation

Author keywords

Ceramic implant abutment; Dental implants; Dynamic loading; Failure mode; Fracture strength; Survival rate

Indexed keywords

ARTICLE; DENTAL SURGERY; DENTURE; HUMAN; MASTICATION; MATERIALS TESTING; PROSTHESIS; PROSTHESIS FAILURE; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 27344446978     PISSN: 0305182X     EISSN: 13652842     Source Type: Journal    
DOI: 10.1111/j.1365-2842.2005.01515.x     Document Type: Article
Times cited : (113)

References (35)
  • 2
    • 0027564887 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants for single-tooth replacement
    • Schmitt A, Zarb GA. The longitudinal clinical effectiveness of osseointegrated dental implants for single-tooth replacement. Int J Prosthodont. 1993;6:197-202.
    • (1993) Int J Prosthodont , vol.6 , pp. 197-202
    • Schmitt, A.1    Zarb, G.A.2
  • 3
    • 0030184468 scopus 로고    scopus 로고
    • Osseointegrated implants for single-tooth replacement: A prospective 5-year multicenter study
    • Henry PJ, Laney WR, Jemt T et al. Osseointegrated implants for single-tooth replacement: a prospective 5-year multicenter study. Int J Oral Maxillofac Implants. 1996;11:450-455.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 450-455
    • Henry, P.J.1    Laney, W.R.2    Jemt, T.3
  • 4
    • 0027346459 scopus 로고
    • Esthetic high-strength implant abutments. Part I
    • Prestipino V, Ingber A. Esthetic high-strength implant abutments. Part I. J Esthet Dent. 1993;5:29-36.
    • (1993) J Esthet Dent , vol.5 , pp. 29-36
    • Prestipino, V.1    Ingber, A.2
  • 5
    • 0027566311 scopus 로고
    • Esthetic high-strength implant abutments. Part II
    • Prestipino V, Ingber A. Esthetic high-strength implant abutments. Part II. J Esthet Dent. 1993;5:63-68.
    • (1993) J Esthet Dent , vol.5 , pp. 63-68
    • Prestipino, V.1    Ingber, A.2
  • 6
    • 0033205480 scopus 로고    scopus 로고
    • Glass-infiltrated zirconia/alumina-based ceramic for crowns and fixed partial dentures
    • quiz 996
    • McLaren EA, White SN. Glass-infiltrated zirconia/alumina-based ceramic for crowns and fixed partial dentures. Pract Periodontics Aesthet Dent. 1999;11:985-994; quiz 996.
    • (1999) Pract Periodontics Aesthet Dent , vol.11 , pp. 985-994
    • McLaren, E.A.1    White, S.N.2
  • 7
    • 0032160238 scopus 로고    scopus 로고
    • The mucosal attachment at different abutments. An experimental study in dogs
    • Abrahamsson I, Berglundh T, Glantz PO, Lindhe J. The mucosal attachment at different abutments. An experimental study in dogs. J Clin Periodontol. 1998;25:721-727.
    • (1998) J Clin Periodontol , vol.25 , pp. 721-727
    • Abrahamsson, I.1    Berglundh, T.2    Glantz, P.O.3    Lindhe, J.4
  • 8
    • 0032229542 scopus 로고    scopus 로고
    • In vivo early plaque formation on pure titanium and ceramic abutments: A comparative microbiological and SEM analysis
    • Rasperini G, Maglione M, Cocconcelli P, Simion M. In vivo early plaque formation on pure titanium and ceramic abutments: a comparative microbiological and SEM analysis. Clin Oral Implants Res. 1998;9:357-364.
    • (1998) Clin Oral Implants Res , vol.9 , pp. 357-364
    • Rasperini, G.1    Maglione, M.2    Cocconcelli, P.3    Simion, M.4
  • 9
    • 0035453135 scopus 로고    scopus 로고
    • Alumina ceramic implant abutments used for single-tooth replacement: A prospective 1- to 3-year multicenter study
    • Andersson B, Taylor A, Lang BR et al. Alumina ceramic implant abutments used for single-tooth replacement: a prospective 1- to 3-year multicenter study. Int J Prosthodont. 2001;14:432-438.
    • (2001) Int J Prosthodont , vol.14 , pp. 432-438
    • Andersson, B.1    Taylor, A.2    Lang, B.R.3
  • 10
    • 0348112456 scopus 로고    scopus 로고
    • Ceramic implant abutments for short-span FPDs: A prospective 5-year multicenter study
    • Andersson B, Glauser R, Maglione M, Taylor A. Ceramic implant abutments for short-span FPDs: a prospective 5-year multicenter study. Int J Prosthodont. 2003;16:640-646.
    • (2003) Int J Prosthodont , vol.16 , pp. 640-646
    • Andersson, B.1    Glauser, R.2    Maglione, M.3    Taylor, A.4
  • 11
    • 2542639442 scopus 로고    scopus 로고
    • Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-Year results of a prospective clinical study
    • Glauser R, Sailer I, Wohlwend A, Studer S, Schibli M, Schärer P. Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study. Int J Prosthodont. 2004;17:285-290.
    • (2004) Int J Prosthodont , vol.17 , pp. 285-290
    • Glauser, R.1    Sailer, I.2    Wohlwend, A.3    Studer, S.4    Schibli, M.5    Schärer, P.6
  • 13
    • 0346406320 scopus 로고    scopus 로고
    • The external hexagonal interface and screw-joint stability: A primer on threaded fasteners
    • Binon PP. The external hexagonal interface and screw-joint stability: a primer on threaded fasteners. Qintessence Dent Technol. 2000;23:91-105.
    • (2000) Qintessence Dent Technol , vol.23 , pp. 91-105
    • Binon, P.P.1
  • 14
    • 0033628712 scopus 로고    scopus 로고
    • Implants and components: Entering the new millennium
    • Binon PP. Implants and components: entering the new millennium. Int J Oral Maxillofac Implants. 2000;15:76-94.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 76-94
    • Binon, P.P.1
  • 15
    • 0038315249 scopus 로고    scopus 로고
    • The ZiReal post: A new ceramic implant abutment
    • Brodbeck U. The ZiReal post: a new ceramic implant abutment. J Esthet Restor Dent. 2003;15:10-23, discussion 24.
    • (2003) J Esthet Restor Dent , vol.15 , pp. 10-23
    • Brodbeck, U.1
  • 16
    • 27344455523 scopus 로고    scopus 로고
    • Single-tooth replacement with a new zirconia titanium cylinder implant abutment: A case report
    • Strub JR, Butz F, Semsch R. Single-tooth replacement with a new zirconia titanium cylinder implant abutment: a case report. Quintessence Dent Technol. 2003;26:171-178.
    • (2003) Quintessence Dent Technol , vol.26 , pp. 171-178
    • Strub, J.R.1    Butz, F.2    Semsch, R.3
  • 17
    • 0020688695 scopus 로고
    • Development of an artificial oral environment for the testing of dental restoratives: Bi-axial force and movement control
    • DeLong R, Douglas WH. Development of an artificial oral environment for the testing of dental restoratives: bi-axial force and movement control. J Dent Res. 1983;62:32-36.
    • (1983) J Dent Res , vol.62 , pp. 32-36
    • DeLong, R.1    Douglas, W.H.2
  • 18
    • 0037812252 scopus 로고    scopus 로고
    • Fracture strength and failure mode of five different single-tooth implant-abutment combinations
    • Strub JR, Gerds T. Fracture strength and failure mode of five different single-tooth implant-abutment combinations. Int J Prosthodont. 2003;16:167-171.
    • (2003) Int J Prosthodont , vol.16 , pp. 167-171
    • Strub, J.R.1    Gerds, T.2
  • 20
    • 0016750108 scopus 로고
    • Masticatory function - A review of the literature. 2. Speed of movement of the mandible, rate of chewing and forces developed in chewing
    • Bates JF, Stafford GD, Harrison A. Masticatory function - a review of the literature. 2. Speed of movement of the mandible, rate of chewing and forces developed in chewing. J Oral Rehabil. 1975;2:281-301.
    • (1975) J Oral Rehabil , vol.2 , pp. 281-301
    • Bates, J.F.1    Stafford, G.D.2    Harrison, A.3
  • 22
    • 0022962643 scopus 로고
    • The wear of a posterior composite in an artificial mouth: A clinical correlation
    • Sakaguchi RL, Douglas WH, DeLong R, Pintado MR. The wear of a posterior composite in an artificial mouth: a clinical correlation. Dent Mater. 1986;2:235-240.
    • (1986) Dent Mater , vol.2 , pp. 235-240
    • Sakaguchi, R.L.1    Douglas, W.H.2    DeLong, R.3    Pintado, M.R.4
  • 23
    • 0034242686 scopus 로고    scopus 로고
    • Effect of repeated closures on opening torque values in seven abutment-implant systems
    • Weiss EI, Kozak D, Gross MD. Effect of repeated closures on opening torque values in seven abutment-implant systems. J Prosthet Dent. 2000;84:194-199.
    • (2000) J Prosthet Dent , vol.84 , pp. 194-199
    • Weiss, E.I.1    Kozak, D.2    Gross, M.D.3
  • 25
    • 0037735292 scopus 로고    scopus 로고
    • A clinical study of the efficacy of gold-tite square abutment screws in cement-retained implant restorations
    • Drago CJ. A clinical study of the efficacy of gold-tite square abutment screws in cement-retained implant restorations. Int J Oral Maxillofac Implants. 2003;18:273-278.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 273-278
    • Drago, C.J.1
  • 26
    • 0035983868 scopus 로고    scopus 로고
    • Reliability and properties of ground Y-TZP-zirconia ceramics
    • Luthardt RG, Holzhuter M, Sandkuhl O et al. Reliability and properties of ground Y-TZP-zirconia ceramics. J Dent Res. 2002;81:487-491.
    • (2002) J Dent Res , vol.81 , pp. 487-491
    • Luthardt, R.G.1    Holzhuter, M.2    Sandkuhl, O.3
  • 27
    • 0026921977 scopus 로고
    • Loads and designs of screw joints for single crowns supported by osseointegrated implants
    • Jörneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants. 1992;7:353-359.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 353-359
    • Jörneus, L.1    Jemt, T.2    Carlsson, L.3
  • 30
    • 0141923180 scopus 로고    scopus 로고
    • In vivo fracture resistance of implant-supported all-ceramic restorations
    • Yildirim M, Fischer H, Marx R, Edelhoff D. In vivo fracture resistance of implant-supported all-ceramic restorations. J Prosthet Dent. 2003;90:325-331.
    • (2003) J Prosthet Dent , vol.90 , pp. 325-331
    • Yildirim, M.1    Fischer, H.2    Marx, R.3    Edelhoff, D.4
  • 31
    • 0018322406 scopus 로고
    • Functional state, bite force and postural muscle activity in patients with osseointegrated oral implant bridges
    • Haraldson T, Carlsson GE, Ingervall B. Functional state, bite force and postural muscle activity in patients with osseointegrated oral implant bridges. Acta Odontol Scand. 1979;37:195-206.
    • (1979) Acta Odontol Scand , vol.37 , pp. 195-206
    • Haraldson, T.1    Carlsson, G.E.2    Ingervall, B.3
  • 33
    • 85047681494 scopus 로고    scopus 로고
    • Micromotion and dynamic fatigue properties of the dental implant-abutment interface
    • Gratton DG, Aquilino SA, Stanford CM. Micromotion and dynamic fatigue properties of the dental implant-abutment interface. J Prosthet Dent. 2001;85:47-52.
    • (2001) J Prosthet Dent , vol.85 , pp. 47-52
    • Gratton, D.G.1    Aquilino, S.A.2    Stanford, C.M.3
  • 34
    • 1942456934 scopus 로고    scopus 로고
    • Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system
    • Khraisat A, Hashimoto A, Nomura S, Miyakawa O. Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system. J Prosthet Dent. 2004;91:326-334.
    • (2004) J Prosthet Dent , vol.91 , pp. 326-334
    • Khraisat, A.1    Hashimoto, A.2    Nomura, S.3    Miyakawa, O.4
  • 35
    • 0033129752 scopus 로고    scopus 로고
    • Wear of composite resin veneering materials in a dual-axis chewing simulator
    • Kern M, Strub JR, Lu XY. Wear of composite resin veneering materials in a dual-axis chewing simulator. J Oral Rehabil. 1999;26:372-378.
    • (1999) J Oral Rehabil , vol.26 , pp. 372-378
    • Kern, M.1    Strub, J.R.2    Lu, X.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.