메뉴 건너뛰기




Volumn 75, Issue 2, 2005, Pages 414-424

Defect-induced fatigue microcrack formation in cement mantle

Author keywords

Acoustic emission; Acrylic bone cement; Microcrack formation; Stress intensity

Indexed keywords

ACOUSTIC EMISSIONS; ACRYLICS; DEFECTS; FATIGUE OF MATERIALS; MICROCRACKS; MORPHOLOGY; SCANNING ELECTRON MICROSCOPY; STRESSES;

EID: 26844452804     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.a.30446     Document Type: Article
Times cited : (12)

References (14)
  • 1
    • 0026864135 scopus 로고
    • A fractographic investigation of PMMA bone cement focusing on the relationship between porosity reduction and increased fatigue life
    • James SP, Jasty M, Davies J, Piehler H, Harris WH. A fractographic investigation of PMMA bone cement focusing on the relationship between porosity reduction and increased fatigue life. J Biomed Mater Res 1992;26:651-662.
    • (1992) J Biomed Mater Res , vol.26 , pp. 651-662
    • James, S.P.1    Jasty, M.2    Davies, J.3    Piehler, H.4    Harris, W.H.5
  • 2
    • 0031668067 scopus 로고    scopus 로고
    • Effects of distal cement voids on cement stress in total hip arthroplasty
    • Powers CM, Lee IY, Skinner HB, Keyak JH. Effects of distal cement voids on cement stress in total hip arthroplasty. J Arthroplasty 1998;13:793-798.
    • (1998) J Arthroplasty , vol.13 , pp. 793-798
    • Powers, C.M.1    Lee, I.Y.2    Skinner, H.B.3    Keyak, J.H.4
  • 3
    • 0028500672 scopus 로고
    • Effects of variation of prosthesis size on cement stress at the tip of a femoral implant
    • Lee IY, Skinner HB, Keyak JH. Effects of variation of prosthesis size on cement stress at the tip of a femoral implant. J Biomed Mater Res 1994;28:1055-1060.
    • (1994) J Biomed Mater Res , vol.28 , pp. 1055-1060
    • Lee, I.Y.1    Skinner, H.B.2    Keyak, J.H.3
  • 4
    • 0025388865 scopus 로고
    • A fractographic analysis of in vivo poly(methyl methacrylate) bone cement failure mechanisms
    • Topoleski LD, Ducheyne P, Cuckler JM. A fractographic analysis of in vivo poly(methyl methacrylate) bone cement failure mechanisms. J Biomed Mater Res 1990;24:135-154.
    • (1990) J Biomed Mater Res , vol.24 , pp. 135-154
    • Topoleski, L.D.1    Ducheyne, P.2    Cuckler, J.M.3
  • 5
    • 0027533403 scopus 로고
    • Fatigue failure in the cement mantle of an artificial hip joint
    • Culleton TP, Prendergast PJ, Taylor D. Fatigue failure in the cement mantle of an artificial hip joint. Clin Mater 1993;12:95-102.
    • (1993) Clin Mater , vol.12 , pp. 95-102
    • Culleton, T.P.1    Prendergast, P.J.2    Taylor, D.3
  • 6
    • 0033397260 scopus 로고    scopus 로고
    • Do voids in a femoral cement mantle affect the outcome?
    • Hernigou P, Le Mouel S. Do voids in a femoral cement mantle affect the outcome? J Arthroplasty 1999;14:1005-1010.
    • (1999) J Arthroplasty , vol.14 , pp. 1005-1010
    • Hernigou, P.1    Le Mouel, S.2
  • 7
    • 0031278149 scopus 로고    scopus 로고
    • On predicting the fracture behavior of CFR and GFR composites using wavelet-based AE techniques
    • Qi G, Barhorst AA. On predicting the fracture behavior of CFR and GFR composites using wavelet-based AE techniques. Eng Fract Mech 1997;58:363-385.
    • (1997) Eng Fract Mech , vol.58 , pp. 363-385
    • Qi, G.1    Barhorst, A.A.2
  • 8
    • 0033874371 scopus 로고    scopus 로고
    • Wavelet-based AE characterization of composite materials
    • Qi G. Wavelet-based AE characterization of composite materials. NDT&E Int 2000;33:133-144.
    • (2000) NDT&E Int , vol.33 , pp. 133-144
    • Qi, G.1
  • 9
    • 0034333642 scopus 로고    scopus 로고
    • 3D AE visualization of bone cement fatigue crack locations
    • Qi G, Pujol J, Fan ZF. 3D AE Visualization of bone cement fatigue crack locations. J Biomed Mater Res 2000;52:256-260.
    • (2000) J Biomed Mater Res , vol.52 , pp. 256-260
    • Qi, G.1    Pujol, J.2    Fan, Z.F.3
  • 10
    • 0000533430 scopus 로고    scopus 로고
    • Numerical assessment of the quality of AE locations in the presence of noises
    • Qi G, Pujol J. Numerical assessment of the quality of AE locations in the presence of noises. J Acoustic Emission 2000; 17:111-120.
    • (2000) J Acoustic Emission , vol.17 , pp. 111-120
    • Qi, G.1    Pujol, J.2
  • 14
    • 0035902899 scopus 로고    scopus 로고
    • Investigation of fatigue crack propagation behavior of bone cement by wavelet based acoustic emission analysis
    • Ng ET, Qi G. Investigation of fatigue crack propagation behavior of bone cement by wavelet based acoustic emission analysis. Eng Fract Mech 2001;68:1477-1492.
    • (2001) Eng Fract Mech , vol.68 , pp. 1477-1492
    • Ng, E.T.1    Qi, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.