메뉴 건너뛰기




Volumn 2, Issue 5, 2005, Pages 599-603

Staple-line buttressing material in gastric-bypass surgery

Author keywords

Anastomotic leaks; Bovine pericardium strip; Fibrin glue; GI anastomosis; Morbid obesity; Roux en Y gastric bypass; Suture line reinforcement; Tibrin sealant

Indexed keywords

FIBRIN GLUE;

EID: 26844452608     PISSN: 17434440     EISSN: 17452422     Source Type: Journal    
DOI: 10.1586/17434440.2.5.599     Document Type: Review
Times cited : (4)

References (31)
  • 1
    • 0942266263 scopus 로고    scopus 로고
    • The surgical management of severe obesity
    • Herron D. The surgical management of severe obesity. Mt Sinai J. Med. 71(1), 63-71 (2004).
    • (2004) Mt. Sinai J. Med. , vol.71 , Issue.1 , pp. 63-71
    • Herron, D.1
  • 2
    • 0036936565 scopus 로고    scopus 로고
    • Medical and surgical options in the treatment of severe obesity
    • Fischer BL, Schauer P. Medical and surgical options in the treatment of severe obesity. Am. J. Surg. 184, S9-S16 (2002).
    • (2002) Am. J. Surg. , vol.184
    • Fischer, B.L.1    Schauer, P.2
  • 4
    • 7644222812 scopus 로고    scopus 로고
    • The use of bovine pericardial strips on linear stapler to reduce extraluminal bleeding during laparoscopic gastric bypass: Prospective randomized clinical trial
    • Angrisani L, Lorenzo M, Borreli V et al. The use of bovine pericardial strips on linear stapler to reduce extraluminal bleeding during laparoscopic gastric bypass: prospective randomized clinical trial. Obes. Surg. 14(9), 1198-1202 (2004).
    • (2004) Obes. Surg. , vol.14 , Issue.9 , pp. 1198-1202
    • Angrisani, L.1    Lorenzo, M.2    Borreli, V.3
  • 5
    • 0003649582 scopus 로고    scopus 로고
    • 16th Edition. Elsevier, Amsterdam, The Netherlands
    • Townsend C. Sabiston Textbook of Surgery. 16th Edition. Elsevier, Amsterdam, The Netherlands, 218-219 (2001).
    • (2001) Sabiston Textbook of Surgery , pp. 218-219
    • Townsend, C.1
  • 6
    • 0027424702 scopus 로고
    • Transient protection of incomplete colonic anastomoses with fibrin sealant: An experimental study in the rat
    • van der Ham A, Kort WJ, Weijma IM, Jeekel H. Transient protection of incomplete colonic anastomoses with fibrin sealant: an experimental study in the rat. J. Surg. Res. 55, 256-260 (1993).
    • (1993) J. Surg. Res. , vol.55 , pp. 256-260
    • van der Ham, A.1    Kort, W.J.2    Weijma, I.M.3    Jeekel, H.4
  • 9
    • 0022368291 scopus 로고
    • Fibrin glue safety: Inactivation of potential viral contaminations by pasteurization of the human plasma components
    • Hilfenhaus J, Weidmann E. Fibrin glue safety: inactivation of potential viral contaminations by pasteurization of the human plasma components. Arzneimittelforschung 35(11), 1617-1619 (1985).
    • (1985) Arzneimittelforschung , vol.35 , Issue.11 , pp. 1617-1619
    • Hilfenhaus, J.1    Weidmann, E.2
  • 10
    • 0042130530 scopus 로고    scopus 로고
    • Fatal intraoperative anaphylaxis related to aprotinin after local application of fibrin glue
    • Oswald A, Joly L, Gury C et al. Fatal intraoperative anaphylaxis related to aprotinin after local application of fibrin glue. Anesthesiology 99(3), 762-763 (2003).
    • (2003) Anesthesiology , vol.99 , Issue.3 , pp. 762-763
    • Oswald, A.1    Joly, L.2    Gury, C.3
  • 11
    • 0025859245 scopus 로고
    • Warning: Fatal reaction to the use of fibrin glue in deep hepatic wounds. Case reports
    • Berguer R, Staerkel RL, Moore EE et al. Warning: fatal reaction to the use of fibrin glue in deep hepatic wounds. Case reports. J. Trauma 31(3), 408-411 (1991).
    • (1991) J. Trauma , vol.31 , Issue.3 , pp. 408-411
    • Berguer, R.1    Staerkel, R.L.2    Moore, E.E.3
  • 12
    • 0034754408 scopus 로고    scopus 로고
    • The use of fibrin glue in skin grafts and tissue-engineered skin replacements: A review
    • Currie LJ, Sharpe JR, Martin R. The use of fibrin glue in skin grafts and tissue-engineered skin replacements: a review. Plast. Reconstr. Surg. 108, 1713-1726 (2001).
    • (2001) Plast. Reconstr. Surg. , vol.108 , pp. 1713-1726
    • Currie, L.J.1    Sharpe, J.R.2    Martin, R.3
  • 13
    • 0031594445 scopus 로고    scopus 로고
    • In vivo wound healing response to a modified degradable fibrin scaffold
    • Pandit AS, Feldman DS, Caulfield J. In vivo wound healing response to a modified degradable fibrin scaffold. J. Biomater. Appl. 12, 222-236 (1998).
    • (1998) J. Biomater. Appl. , vol.12 , pp. 222-236
    • Pandit, A.S.1    Feldman, D.S.2    Caulfield, J.3
  • 14
    • 10644252821 scopus 로고    scopus 로고
    • Use of fibrin sealant in laparoscopic gastric bypass for the morbidly obese
    • Lee MM, Provost DA, Jones DB. Use of fibrin sealant in laparoscopic gastric bypass for the morbidly obese. Obes. Surg. 14, 1321-1326 (2004).
    • (2004) Obes. Surg. , vol.14 , pp. 1321-1326
    • Lee, M.M.1    Provost, D.A.2    Jones, D.B.3
  • 15
    • 0031965309 scopus 로고    scopus 로고
    • Effect of fibrin glue on small and large bowel anastomoses in rat
    • Shinohara K, Kobayashi E, Yoshida T et al. Effect of fibrin glue on small and large bowel anastomoses in rat. Eur. Surg. Res. 30(1), 8-12 (1998).
    • (1998) Eur. Surg. Res. , vol.30 , Issue.1 , pp. 8-12
    • Shinohara, K.1    Kobayashi, E.2    Yoshida, T.3
  • 17
    • 0032774902 scopus 로고    scopus 로고
    • Sutureless small bowel anstomoses: Experimental study in pigs
    • Zilling T, Jansson O, Walther BS, Ottosson A. Sutureless small bowel anstomoses: experimental study in pigs. Eur. J. Surg. 165(1), 61-68 (1999).
    • (1999) Eur. J. Surg. , vol.165 , Issue.1 , pp. 61-68
    • Zilling, T.1    Jansson, O.2    Walther, B.S.3    Ottosson, A.4
  • 19
    • 0037330222 scopus 로고    scopus 로고
    • Fibrin glue as a sealant for high-risk anastomosis in surgery for morbid obesity
    • Liu CD, Glantz GJ, Livingston EH et al. Fibrin glue as a sealant for high-risk anastomosis in surgery for morbid obesity. Obes. Surg. 13, 45-48 (2003).
    • (2003) Obes. Surg. , vol.13 , pp. 45-48
    • Liu, C.D.1    Glantz, G.J.2    Livingston, E.H.3
  • 20
    • 0035138613 scopus 로고    scopus 로고
    • A comparative study of buttressed versus nonbuttressed staple line in pulmonary resections
    • Miller J, Landreneau RJ, Wright CE, Santucci TS, Sammons BH. A comparative study of buttressed versus nonbuttressed staple line in pulmonary resections. Ann. Thorac. Surg. 71(1), 319-323 (2001).
    • (2001) Ann. Thorac. Surg. , vol.71 , Issue.1 , pp. 319-323
    • Miller, J.1    Landreneau, R.J.2    Wright, C.E.3    Santucci, T.S.4    Sammons, B.H.5
  • 21
    • 0034536036 scopus 로고    scopus 로고
    • Buttressing the staple line in lung volume reduction surgery: A randomized three center study
    • Stammberger U, Klepetko W, Stamatis G. Buttressing the staple line in lung volume reduction surgery: a randomized three center study. Ann. Thorac. Surg. 70(6), 1820-1825 (2000).
    • (2000) Ann. Thorac. Surg. , vol.70 , Issue.6 , pp. 1820-1825
    • Stammberger, U.1    Klepetko, W.2    Stamatis, G.3
  • 22
    • 26844573813 scopus 로고    scopus 로고
    • Comparing seam burst pressure: Buttressed versus non-buttressed linear cutting staple devices in a porcine model
    • Presented at the 19th Annual Meeting of the American Society for Bariatric Surgery, June 24-29
    • Arnold W. Comparing seam burst pressure: buttressed versus non-buttressed linear cutting staple devices in a porcine model. Presented at the 19th Annual Meeting of the American Society for Bariatric Surgery, June 24-29 (2002).
    • (2002)
    • Arnold, W.1
  • 23
    • 0037328068 scopus 로고    scopus 로고
    • Reinforcing gastric staple-lines with bovine pericardial strips may decrease the likelihood of gastric leak after laparosoopic Roux-en-Y gastric bypass
    • Shikora SA, Kim JJ, Tarnoff ME. Reinforcing gastric staple-lines with bovine pericardial strips may decrease the likelihood of gastric leak after laparosoopic Roux-en-Y gastric bypass. Obes. Surg. 13, 37-44 (2003).
    • (2003) Obes. Surg. , vol.13 , pp. 37-44
    • Shikora, S.A.1    Kim, J.J.2    Tarnoff, M.E.3
  • 25
    • 0029741767 scopus 로고    scopus 로고
    • A randomized study comparing laparoscopic versus open repair of perforated peptic ulcer using suture or sutureless technique
    • Lau W, Leung KL, Kwong KH. A randomized study comparing laparoscopic versus open repair of perforated peptic ulcer using suture or sutureless technique. Ann. Surg. 224(2), 131-138 (1996).
    • (1996) Ann. Surg. , vol.224 , Issue.2 , pp. 131-138
    • Lau, W.1    Leung, K.L.2    Kwong, K.H.3
  • 26
    • 0035169489 scopus 로고    scopus 로고
    • Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair
    • Katkhouda N, Mavor E, Friedlander MH et al. Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair. Ann. Surg. 233(1), 18-25 (2001).
    • (2001) Ann. Surg. , vol.233 , Issue.1 , pp. 18-25
    • Katkhouda, N.1    Mavor, E.2    Friedlander, M.H.3
  • 27
    • 0029377540 scopus 로고
    • Sutured or fibrin-glued laparoscopic choledochojejunostomy
    • Jones D, Brewer JD, Meininger TA, Soper NJ. Sutured or fibrin-glued laparoscopic choledochojejunostomy. Surg. Endosc. 9(9), 1020-1027 (1995).
    • (1995) Surg. Endosc. , vol.9 , Issue.9 , pp. 1020-1027
    • Jones, D.1    Brewer, J.D.2    Meininger, T.A.3    Soper, N.J.4
  • 28
    • 14644423266 scopus 로고    scopus 로고
    • A comparison of burst pressure between buttressed versus non-buttressed staple-lines in an animal model
    • Arnold W, Shikora S. A comparison of burst pressure between buttressed versus non-buttressed staple-lines in an animal model. Obes. Surg. 15, 164-171 (2005).
    • (2005) Obes. Surg. , vol.15 , pp. 164-171
    • Arnold, W.1    Shikora, S.2
  • 29
    • 0030423162 scopus 로고    scopus 로고
    • Assessment of alternative tissue approximation techniques for laparoscopy
    • Eden C, Coptcoat MJ. Assessment of alternative tissue approximation techniques for laparoscopy. Br. J. Urol. 78, 234-242 (1996).
    • (1996) Br. J. Urol. , vol.78 , pp. 234-242
    • Eden, C.1    Coptcoat, M.J.2
  • 30
    • 0028127150 scopus 로고
    • Laparoscopic ureteral reanastomosis using fibrin glue
    • McKay T, Albala DM, Gehrin BE, Castelli M. Laparoscopic ureteral reanastomosis using fibrin glue. J. Urol. 152, 1637-1640 (1994).
    • (1994) J. Urol. , vol.152 , pp. 1637-1640
    • McKay, T.1    Albala, D.M.2    Gehrin, B.E.3    Castelli, M.4
  • 31
    • 0030943753 scopus 로고    scopus 로고
    • Comparison of fibrin glue, laser weld, and mechanical suturing device for the laparoscopic closure of ureterotomy in a porcine model
    • Wolf J, Soble JJ, Nakada SY et al. Comparison of fibrin glue, laser weld, and mechanical suturing device for the laparoscopic closure of ureterotomy in a porcine model. J. Urol. 157, 1487-1492 (1997).
    • (1997) J. Urol. , vol.157 , pp. 1487-1492
    • Wolf, J.1    Soble, J.J.2    Nakada, S.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.