메뉴 건너뛰기




Volumn 14, Issue 9, 2004, Pages 1198-1202

The use of bovine pericardial strips on linear stapler to reduce extraluminal bleeding during laparoscopic gastric bypass: Prospective randomized clinical trial

Author keywords

Bleeding; Bovine pericardium strips; Gastric bypass; Laparoscopy; Linear stapler; Morbid obesity

Indexed keywords

METHYLENE BLUE;

EID: 7644222812     PISSN: 09608923     EISSN: None     Source Type: Journal    
DOI: 10.1381/0960892042387075     Document Type: Article
Times cited : (68)

References (12)
  • 1
    • 0037334704 scopus 로고    scopus 로고
    • Lap Band: Adjustable gastric banding system. The Italian experience with 1863 patients operated in 6 years
    • Angrisani L, Favretti F, Furbetta F and Italian Group for Lap-Band System. Lap Band: adjustable gastric banding system. The Italian experience with 1863 patients operated in 6 years. Surg Endosc 2033; 17: 409-12.
    • (2033) Surg Endosc , vol.17 , pp. 409-412
    • Angrisani, L.1    Favretti, F.2    Furbetta, F.3
  • 2
    • 0033825385 scopus 로고    scopus 로고
    • Laparoscopic gastric bypass, Roux-en-Y - 500 patients: Technique and results, with 3-60 months follow up
    • Wittgrove AC, Clark GW. Laparoscopic gastric bypass, Roux-en-Y - 500 patients: technique and results, with 3-60 months follow up. Obes Surg 2000; 10: 233-9.
    • (2000) Obes Surg , vol.10 , pp. 233-239
    • Wittgrove, A.C.1    Clark, G.W.2
  • 3
    • 0018128266 scopus 로고
    • The stapled gastrointestinal tract anastomosis: Incidence of postoperative complications compared with the sutured anastomosis
    • Chassin JL, Rifkind KM, Sussmann B et al. The stapled gastrointestinal tract anastomosis: incidence of postoperative complications compared with the sutured anastomosis. Ann Surg 1978; 188: 689-92.
    • (1978) Ann Surg , vol.188 , pp. 689-692
    • Chassin, J.L.1    Rifkind, K.M.2    Sussmann, B.3
  • 4
    • 0347517719 scopus 로고    scopus 로고
    • Management of acute bleeding after laparoscopic Roux-en-Y gastric bypass
    • Mehran A, Szomstein S, Zundel N et al. Management of acute bleeding after laparoscopic Roux-en-Y gastric bypass. Obes Surg 2003; 13: 842-7.
    • (2003) Obes Surg , vol.13 , pp. 842-847
    • Mehran, A.1    Szomstein, S.2    Zundel, N.3
  • 5
    • 0030842841 scopus 로고    scopus 로고
    • Effect of bovine pericardial strip on air leak after stapled pulmonary resection
    • Hazelrigg SR, Boley TM, Naunheim KS et al. Effect of bovine pericardial strip on air leak after stapled pulmonary resection. Ann Thorac Surg 1997; 63: 1573-5.
    • (1997) Ann Thorac Surg , vol.63 , pp. 1573-1575
    • Hazelrigg, S.R.1    Boley, T.M.2    Naunheim, K.S.3
  • 6
    • 0034536036 scopus 로고    scopus 로고
    • Buttressing the staple line in lung volume reduction surgery: A randomized three-center study
    • Stammberger U, Klepetko W, Stamatis G et al. Buttressing the staple line in lung volume reduction surgery: a randomized three-center study. Ann Thorac Surg 2000; 70: 1820-5.
    • (2000) Ann Thorac Surg , vol.70 , pp. 1820-1825
    • Stammberger, U.1    Klepetko, W.2    Stamatis, G.3
  • 7
    • 0037328068 scopus 로고    scopus 로고
    • Reinforcing staple-lines with bovine pericardial strips may decrease the likelihood of gastric leak after laparoscopic Roux-en-Y gastric bypass
    • Shikora SA, Kim JJ, Tarnoff ME. Reinforcing staple-lines with bovine pericardial strips may decrease the likelihood of gastric leak after laparoscopic Roux-en-Y gastric bypass. Obes Surg 2003; 3: 37-44.
    • (2003) Obes Surg , vol.3 , pp. 37-44
    • Shikora, S.A.1    Kim, J.J.2    Tarnoff, M.E.3
  • 8
    • 7644239252 scopus 로고
    • Tavole numeriche
    • Lison L. Milano: Ed It
    • Lison L. Tavole Numeriche. In: Lison L. Statistica Applicata. Milano: Ed It 1986; 272-3.
    • (1986) Statistica Applicata , pp. 272-273
    • Lison, L.1
  • 9
    • 0017159651 scopus 로고
    • Bleeding from stapler anastomosis
    • Fisher MG. Bleeding from stapler anastomosis. Am J Surg 1976; 131: 745-50.
    • (1976) Am J Surg , vol.131 , pp. 745-750
    • Fisher, M.G.1
  • 10
    • 0017753202 scopus 로고
    • Complications associated with the use of gastrointestinal stapling device
    • Wassner JD, Yohai E, Heimlich HJ. Complications associated with the use of gastrointestinal stapling device. Surgery 1977; 82: 395-9.
    • (1977) Surgery , vol.82 , pp. 395-399
    • Wassner, J.D.1    Yohai, E.2    Heimlich, H.J.3
  • 11
    • 0021952321 scopus 로고
    • Stapler devices in gastrointestinal surgery
    • Tuchmann A, Dinstl K, Strasser K et al. Stapler devices in gastrointestinal surgery. Int Surg 1985; 70: 23-7.
    • (1985) Int Surg , vol.70 , pp. 23-27
    • Tuchmann, A.1    Dinstl, K.2    Strasser, K.3
  • 12
    • 0348147555 scopus 로고    scopus 로고
    • Prospective randomized comparison of linear staplers during laparoscopic Roux-en-Y gastric bypass
    • Champion JK, Williams MD. Prospective randomized comparison of linear staplers during laparoscopic Roux-en-Y gastric bypass. Obes Surg 2003; 13: 855-60.
    • (2003) Obes Surg , vol.13 , pp. 855-860
    • Champion, J.K.1    Williams, M.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.