메뉴 건너뛰기




Volumn 26 II, Issue , 2004, Pages 968-971

MMG-based classification of muscle activity for prosthesis control

Author keywords

Data fusion; Mechanomyography; Muscle activity classification; Prosthesis control; Sensor fusion

Indexed keywords

ALGORITHMS; BIOMECHANICS; DATA ACQUISITION; ELECTROMYOGRAPHY; OPTIMIZATION; PROSTHETICS; SENSOR DATA FUSION; SIGNAL PROCESSING; SIGNAL TO NOISE RATIO;

EID: 11144273247     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (52)

References (10)
  • 1
    • 0038179436 scopus 로고    scopus 로고
    • Systematic characterisation of silicon-embedded accelerometers for mechanomyography
    • in press
    • J. Silva, T. Chau, S. Naumann, and W. Heim, "Systematic characterisation of silicon-embedded accelerometers for mechanomyography," Med. Biol. Eng. Comput., in press.
    • Med. Biol. Eng. Comput.
    • Silva, J.1    Chau, T.2    Naumann, S.3    Heim, W.4
  • 3
    • 0027155822 scopus 로고
    • Muscle sound: Bases for the introduction of a mechanomyographic signal in muscle studies
    • C. Orizio, "Muscle sound: bases for the introduction of a mechanomyographic signal in muscle studies," Crit. Rev. Biomed. Eng., vol. 21, no. 3, pp. 201-243, 1993.
    • (1993) Crit. Rev. Biomed. Eng. , vol.21 , Issue.3 , pp. 201-243
    • Orizio, C.1
  • 4
    • 0026097944 scopus 로고
    • Acoustic myography as an indicator of force during sustained contractions of a small hand muscle
    • M. S. Goldenberg, H. J. Yack, F. J. Cerny, and H. W. Burton, "Acoustic myography as an indicator of force during sustained contractions of a small hand muscle," J. Appl. Physiol., vol. 70, no. 1, pp. 87-91, 1991.
    • (1991) J. Appl. Physiol. , vol.70 , Issue.1 , pp. 87-91
    • Goldenberg, M.S.1    Yack, H.J.2    Cerny, F.J.3    Burton, H.W.4
  • 5
    • 0032862320 scopus 로고    scopus 로고
    • Acoustic myography during voluntary isometric contraction reveals non-propagative lateral vibration
    • M. Ouamer, M. Boiteux, M. Petitjean, L. Travens, and A. Sal'es, "Acoustic myography during voluntary isometric contraction reveals non-propagative lateral vibration," J. Biomech., vol.32, no. 12, pp. 1279-1285, 1999.
    • (1999) J. Biomech. , vol.32 , Issue.12 , pp. 1279-1285
    • Ouamer, M.1    Boiteux, M.2    Petitjean, M.3    Travens, L.4    Sal'es, A.5
  • 6
    • 0022587670 scopus 로고
    • Acoustic myography as a control signal for an externally powered prosthesis
    • D. T. Barry, J. A. Leonard, A. J. Gitter, and R. D. Ball, "Acoustic myography as a control signal for an externally powered prosthesis," Arch. Phys. Med. Rehab., vol. 67, no. 4, pp. 267-269, 1986.
    • (1986) Arch. Phys. Med. Rehab. , vol.67 , Issue.4 , pp. 267-269
    • Barry, D.T.1    Leonard, J.A.2    Gitter, A.J.3    Ball, R.D.4
  • 8
    • 0142185498 scopus 로고    scopus 로고
    • Coupled microphone-accelerometer sensor pair for dynamic noise reduction in MMG signal recording
    • October
    • J. Silva and T. Chau, "Coupled Microphone-Accelerometer Sensor Pair for Dynamic Noise Reduction in MMG Signal Recording," Electronics Letters, Vol. 39, No. 21, pp. 1496-1498, October 2003.
    • (2003) Electronics Letters , vol.39 , Issue.21 , pp. 1496-1498
    • Silva, J.1    Chau, T.2
  • 9
    • 0000238336 scopus 로고
    • A simplex method for function minimization
    • J. A. Nelder, and R. Mead, "A Simplex Method for Function Minimization," Computer Journal, Vol. 7, pp. 308-313, 1965.
    • (1965) Computer Journal , vol.7 , pp. 308-313
    • Nelder, J.A.1    Mead, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.