메뉴 건너뛰기




Volumn 5, Issue , 2005, Pages

Measuring body composition in overweight individuals by dual energy x-ray absorptiometry

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMEN; ACCURACY; ARTICLE; BODY COMPOSITION; BODY FAT; BONE DENSITOMETRY; BONE DENSITY; BONE MINERAL; DUAL ENERGY X RAY ABSORPTIOMETRY; HUMAN; OBESITY; SOFT TISSUE; THIGH; WEIGHT REDUCTION;

EID: 26444493205     PISSN: 14712342     EISSN: 14712342     Source Type: Journal    
DOI: 10.1186/1471-2342-5-1     Document Type: Article
Times cited : (49)

References (30)
  • 2
    • 26444540161 scopus 로고    scopus 로고
    • GE Medical Systems, Lunar Corporation. Madison WI
    • GE Medical Systems, Lunar Corporation. DPX Series Operator's Manual. Madison WI 1998.
    • (1998) DPX Series Operator's Manual
  • 3
    • 26444487996 scopus 로고    scopus 로고
    • Bone densitometry, body composition analysis
    • Hologic accessed February
    • Hologic: Bone densitometry, body composition analysis [http://www.hologic.com]. accessed February 2005
    • (2005)
  • 4
    • 0034008503 scopus 로고    scopus 로고
    • Monitoring osteoporosis therapy with bone densitometry: Misleading changes and regression to the mean
    • Fracture Intervention Trial Research Group
    • Cummings SR, Palermo L, Browner W, Marcus R, Wallace R, Pearson J, Blackwell T, Eckert S, Black D: Monitoring osteoporosis therapy with bone densitometry: misleading changes and regression to the mean. Fracture Intervention Trial Research Group. JAMA 2000, 283:1318-1321.
    • (2000) JAMA , vol.283 , pp. 1318-1321
    • Cummings, S.R.1    Palermo, L.2    Browner, W.3    Marcus, R.4    Wallace, R.5    Pearson, J.6    Blackwell, T.7    Eckert, S.8    Black, D.9
  • 5
    • 0034086159 scopus 로고    scopus 로고
    • Comparisons between Hologic QDR 1000W, QDR 4500A, and Lunar Expert dual-energy x-ray absorptiometry scanners used for measuring total body bone and soft tissue
    • Tothill P, Hannan WJ: Comparisons between Hologic QDR 1000W, QDR 4500A, and Lunar Expert dual-energy x-ray absorptiometry scanners used for measuring total body bone and soft tissue. Ann NY Acad Sci 2001, 904:63-71.
    • (2001) Ann. NY Acad. Sci. , vol.904 , pp. 63-71
    • Tothill, P.1    Hannan, W.J.2
  • 6
    • 4444281170 scopus 로고    scopus 로고
    • Comparison of narrow-angle fan-beam and pencil-beam densitometers: In vivo and phantom study of the effect of bone density, scan mode, and tissue depth on spine measurements
    • Laskey MA, Murgatroyd PR, Prentice A: Comparison of narrow-angle fan-beam and pencil-beam densitometers: in vivo and phantom study of the effect of bone density, scan mode, and tissue depth on spine measurements. J Clin Densitometry 2004, 7:341-348.
    • (2004) J. Clin. Densitometry , vol.7 , pp. 341-348
    • Laskey, M.A.1    Murgatroyd, P.R.2    Prentice, A.3
  • 7
    • 0034096222 scopus 로고    scopus 로고
    • Assessing body composition and changes in body composition. Another look at dual energy x-ray absorptiometry
    • Lohman TG, Harris M, Teixeira PJ, Weiss L: Assessing body composition and changes in body composition. Another look at dual energy x-ray absorptiometry. Ann NY Acad Sci 2000, 904:45-54.
    • (2000) Ann. NY Acad. Sci. , vol.904 , pp. 45-54
    • Lohman, T.G.1    Harris, M.2    Teixeira, P.J.3    Weiss, L.4
  • 8
    • 0037306912 scopus 로고    scopus 로고
    • Comparison of the effectiveness of 2 Dual-energy x-ray absorptiometers with that of total body water and computed tomography in assessing changes in body composition during weight change
    • Tylavsky FA, Lohman TG, Dockrell M, Lang T, Schoeller DA, Wan JY, Fuerst T, Cauley JA, Nevitt M, Harris TB: Comparison of the effectiveness of 2 Dual-energy x-ray absorptiometers with that of total body water and computed tomography in assessing changes in body composition during weight change. Am J Clin Nutr 2003, 77:356-363.
    • (2003) Am. J. Clin. Nutr. , vol.77 , pp. 356-363
    • Tylavsky, F.A.1    Lohman, T.G.2    Dockrell, M.3    Lang, T.4    Schoeller, D.A.5    Wan, J.Y.6    Fuerst, T.7    Cauley, J.A.8    Nevitt, M.9    Harris, T.B.10
  • 9
    • 7244233018 scopus 로고    scopus 로고
    • Comparison of dual-energy x-ray absorptiometry machines for measuring fat distribution changes of HIV-associated lipodystrophy
    • Yang Y, Zhu WD, Paton NL: Comparison of dual-energy x-ray absorptiometry machines for measuring fat distribution changes of HIV-associated lipodystrophy. Antivir Ther 2004, 9:771-778.
    • (2004) Antivir. Ther. , vol.9 , pp. 771-778
    • Yang, Y.1    Zhu, W.D.2    Paton, N.L.3
  • 10
    • 0027373635 scopus 로고
    • Use of dual-energy x-ray abdorptiometry in body-composition studies: Not yet a "gold standard"
    • Roubenoff R, Kehyias JJ, Dawson-Hughes B, Heymsfield SB: Use of dual-energy x-ray abdorptiometry in body-composition studies: not yet a "gold standard". Am J Clin Nutr 1993, 58:589-591.
    • (1993) Am. J. Clin. Nutr. , vol.58 , pp. 589-591
    • Roubenoff, R.1    Kehyias, J.J.2    Dawson-Hughes, B.3    Heymsfield, S.B.4
  • 12
    • 0033038375 scopus 로고    scopus 로고
    • Measurement of abdominal fat by magnetic resonance imaging, dual-energy x-ray absorptiometry and anthropometry in non-obese men and women
    • Kamel EG, McNeill G, Han TS, Smith FW, Avenell A, Davidson L, Tothill P: Measurement of abdominal fat by magnetic resonance imaging, dual-energy x-ray absorptiometry and anthropometry in non-obese men and women. Int J Obes Relat Metab Disord 1999, 23:686-692.
    • (1999) Int. J. Obes. Relat. Metab. Disord. , vol.23 , pp. 686-692
    • Kamel, E.G.1    McNeill, G.2    Han, T.S.3    Smith, F.W.4    Avenell, A.5    Davidson, L.6    Tothill, P.7
  • 13
    • 0036730686 scopus 로고    scopus 로고
    • Regional subcutaneous-fat loss induced by caloric restriction in obese women
    • Wang J, Laferrere B, Thornton JC, Pierson RN, Pi-Sunyer X: Regional subcutaneous-fat loss induced by caloric restriction in obese women. Obes Res 2002, 10:885-890.
    • (2002) Obes. Res. , vol.10 , pp. 885-890
    • Wang, J.1    Laferrere, B.2    Thornton, J.C.3    Pierson, R.N.4    Pi-Sunyer, X.5
  • 14
    • 0029825825 scopus 로고    scopus 로고
    • Body composition during weight loss in obese patients estimated by dual energy x-ray absorptiometry and by total body potassium
    • Hendel HW, Gotfredsen A, Andersen, Hojgaard L, Hilsted J: Body composition during weight loss in obese patients estimated by dual energy x-ray absorptiometry and by total body potassium. Int J Obes 1996, 20:1111-1119.
    • (1996) Int. J. Obes. , vol.20 , pp. 1111-1119
    • Hendel, H.W.1    Gotfredsen, A.2    Andersen3    Hojgaard, L.4    Hilsted, J.5
  • 15
    • 0032821289 scopus 로고    scopus 로고
    • Body composition changes with diet and exercise in obese women: A comparison of estimates from clinical methods and a 4-component model
    • Evans EM, Saunders MJ, Spano MA, Arngrimsson SA, Lewis RD, Cureton KJ: Body composition changes with diet and exercise in obese women: a comparison of estimates from clinical methods and a 4-component model. Am J Clin Nutr 1999, 70:5-12.
    • (1999) Am. J. Clin. Nutr. , vol.70 , pp. 5-12
    • Evans, E.M.1    Saunders, M.J.2    Spano, M.A.3    Arngrimsson, S.A.4    Lewis, R.D.5    Cureton, K.J.6
  • 16
    • 0030498591 scopus 로고    scopus 로고
    • Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy x-ray absorptiometry during prolonged weight loss
    • Hendel HW, Gotfredsen A, Hojgaard L, Andersen T, Hilsted J: Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy x-ray absorptiometry during prolonged weight loss. Scand J Clin Lab Invest 1996, 56:671-679.
    • (1996) Scand. J. Clin. Lab. Invest. , vol.56 , pp. 671-679
    • Hendel, H.W.1    Gotfredsen, A.2    Hojgaard, L.3    Andersen, T.4    Hilsted, J.5
  • 22
    • 0034487348 scopus 로고    scopus 로고
    • Change in bone mass after Colles' fracture: A case report of unique data collection and long-term implications
    • Ilich JZ, Zito M, Brownbill RA, Joyce ME: Change in bone mass after Colles' fracture: A case report of unique data collection and long-term implications. J Clin Densitometry 2000, 3:383-389.
    • (2000) J. Clin. Densitometry , vol.3 , pp. 383-389
    • Ilich, J.Z.1    Zito, M.2    Brownbill, R.A.3    Joyce, M.E.4
  • 24
    • 0036313840 scopus 로고    scopus 로고
    • Are dual-energy x-ray absorptiometry regional estimates associated with visceral adipose tissue mass?
    • Park Y-W, Heymsfield SB, Gallagher D: Are dual-energy x-ray absorptiometry regional estimates associated with visceral adipose tissue mass? Int J Obes 2002, 26:978-983.
    • (2002) Int. J. Obes. , vol.26 , pp. 978-983
    • Park, Y.-W.1    Heymsfield, S.B.2    Gallagher, D.3
  • 25
    • 18444413513 scopus 로고    scopus 로고
    • The prediction of visceral fat by dual-energy x-ray absorptiometry in the elderly: A comparison with computed tomography and anthropometry
    • Snijder MB, Visser M, Dekker JM, Seidell JC, Fuerst T, Tylavsky F: The prediction of visceral fat by dual-energy x-ray absorptiometry in the elderly: a comparison with computed tomography and anthropometry. Int J Obes 2002, 26:984-993.
    • (2002) Int. J. Obes. , vol.26 , pp. 984-993
    • Snijder, M.B.1    Visser, M.2    Dekker, J.M.3    Seidell, J.C.4    Fuerst, T.5    Tylavsky, F.6
  • 26
    • 0034094681 scopus 로고    scopus 로고
    • Measurement of visceral adipose tissue by DXA combined with anthropometry in obese humans
    • Bertin E, Marcus C, Ruiz J-C, Eschard J-P, Leutenegger M: Measurement of visceral adipose tissue by DXA combined with anthropometry in obese humans. Int J Obes 2000, 24:263-270.
    • (2000) Int. J. Obes. , vol.24 , pp. 263-270
    • Bertin, E.1    Marcus, C.2    Ruiz, J.-C.3    Eschard, J.-P.4    Leutenegger, M.5
  • 27
    • 0032822012 scopus 로고    scopus 로고
    • Validity of fan-beam dual-energy x-ray absorptiometry for measuring fat-free mass and leg muscle mass
    • Health, Aging, and Body Composition Study - Dual Energy Absorptiometry and Body Composition Working Group
    • Visser M, Fuerst T, Lang T, Salamone L, Harris T: Validity of fan-beam dual-energy x-ray absorptiometry for measuring fat-free mass and leg muscle mass. Health, Aging, and Body Composition Study - Dual Energy Absorptiometry and Body Composition Working Group. J Appl Physiol 1999, 87:1513-1520.
    • (1999) J. Appl. Physiol. , vol.87 , pp. 1513-1520
    • Visser, M.1    Fuerst, T.2    Lang, T.3    Salamone, L.4    Harris, T.5
  • 28
    • 0029084864 scopus 로고
    • Use of dual-energy X-ray absorptiometry in obese individuals
    • Tataranni PA, Ravussin E: Use of dual-energy X-ray absorptiometry in obese individuals. Am J Clin Nutr 1995, 62:730-734.
    • (1995) Am. J. Clin. Nutr. , vol.62 , pp. 730-734
    • Tataranni, P.A.1    Ravussin, E.2
  • 29
    • 0032764603 scopus 로고    scopus 로고
    • Anomalies in dual energy x-ray absorptiometry measurements of total-body bone mineral during weight change using Lunar, Hologic and Norland instruments
    • Tothill P, Laskey MA, Orphanidou CI, van Wijk M: Anomalies in dual energy x-ray absorptiometry measurements of total-body bone mineral during weight change using Lunar, Hologic and Norland instruments. Br J Radiol 1999, 72:661-669.
    • (1999) Br. J. Radiol. , vol.72 , pp. 661-669
    • Tothill, P.1    Laskey, M.A.2    Orphanidou, C.I.3    van Wijk, M.4
  • 30
    • 0035084650 scopus 로고    scopus 로고
    • Comparisons between a pencil beam and two fan beam dual energy x-ray absorptiometers used for measuring total body bone and soft tissue
    • Tothill P, Hannan WJ, Wilkinson S: Comparisons between a pencil beam and two fan beam dual energy x-ray absorptiometers used for measuring total body bone and soft tissue. Br J Radiol 2001, 74:166-176.
    • (2001) Br. J. Radiol. , vol.74 , pp. 166-176
    • Tothill, P.1    Hannan, W.J.2    Wilkinson, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.