Validity and reliability of selected commercially available metabolic analyzer systems

Author keywords

Reliability and metabolic analyzer; Validity

Indexed keywords

AUTOMATION; ENERGY METABOLISM; EXERCISE TEST; HUMAN; INSTRUMENTATION; LUNG GAS EXCHANGE; MICROCOMPUTER; OXYGEN CONSUMPTION; REPRODUCIBILITY; REVIEW; SPIROMETRY;

EID: 26444479727     PISSN: 09057188     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1600-0838.2005.00477.x     Document Type: Review
Times cited : (60)

References (48)
  • 1
    • 0029090616 scopus 로고
    • Standardisation of spirometry
    • American Thoracic Society. Standardisation of spirometry. Am J Respir Care 1995: 152: 1107-1136.
    • (1995) Am J Respir Care , vol.152 , pp. 1107-1136
  • 2
    • 0021867355 scopus 로고
    • Variability of respiration and metabolism: Responses to sub maximal cycling and running
    • Armstrong LE, Costill DL. Variability of respiration and metabolism: responses to sub maximal cycling and running. Res Quart Exerc Sport 1985: 56: 93-96.
    • (1985) Res Quart Exerc Sport , vol.56 , pp. 93-96
    • Armstrong, L.E.1    Costill, D.L.2
  • 4
    • 0031790628 scopus 로고
    • Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine
    • Atkinson G, Nevill AM. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med 1988: 26(4): 217-238.
    • (1988) Sports Med , vol.26 , Issue.4 , pp. 217-238
    • Atkinson, G.1    Nevill, A.M.2
  • 5
    • 0003171307 scopus 로고    scopus 로고
    • Variability of maximum oxygen measurement in various metabolic systems
    • Babineau C, Leger L, Long A. Variability of maximum oxygen measurement in various metabolic systems. J Strength Conditioning Res 1999: 13: 4.
    • (1999) J Strength Conditioning Res , vol.13 , pp. 4
    • Babineau, C.1    Leger, L.2    Long, A.3
  • 7
    • 0029974479 scopus 로고    scopus 로고
    • The effects of sample size and variability on the correlation coefficient
    • Bates BT, Zhang S, Dufek JS. The effects of sample size and variability on the correlation coefficient. Med Sci Sports Exerc 1996: 28(3): 386-391.
    • (1996) Med Sci Sports Exerc , vol.28 , Issue.3 , pp. 386-391
    • Bates, B.T.1    Zhang, S.2    Dufek, J.S.3
  • 8
    • 0019782367 scopus 로고
    • Breath-by-breath measurement of true alveolar gas exchange
    • Beaver WL, Lamarra N, Wasserman K. Breath-by-breath measurement of true alveolar gas exchange. J Appl Physiol 1981: 51(6): 1662-1675.
    • (1981) J Appl Physiol , vol.51 , Issue.6 , pp. 1662-1675
    • Beaver, W.L.1    Lamarra, N.2    Wasserman, K.3
  • 9
    • 0015547883 scopus 로고
    • On-line computer analysis and breath-by-breath graphical display of exercise function tests
    • Beaver WL, Wasserman. K, Whipp. BJ. On-line computer analysis and breath-by-breath graphical display of exercise function tests. J Appl Physiol 1973: 34(1): 128-132.
    • (1973) J Appl Physiol , vol.34 , Issue.1 , pp. 128-132
    • Beaver, W.L.1    Wasserman, K.2    Whipp, B.J.3
  • 10
    • 0029038603 scopus 로고
    • Comparing two methods of clinical measurement: A personal history
    • Bland JM, Altman DG. Comparing two methods of clinical measurement: a personal history. Int J Epidemiol 1995: 24(Suppl 1): S7-S14.
    • (1995) Int J Epidemiol , vol.24 , Issue.1 SUPPL.
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 0036514920 scopus 로고    scopus 로고
    • Validity and Reliability of three commercially available breath by breath respiratory systems
    • Carter J, Jukendrup AE. Validity and Reliability of three commercially available breath by breath respiratory systems. Eur J Appl Physiol 2002: 86: 435-441.
    • (2002) Eur J Appl Physiol , vol.86 , pp. 435-441
    • Carter, J.1    Jukendrup, A.E.2
  • 12
    • 0002295527 scopus 로고
    • A method for determining the total respiratory exchange in man
    • Douglas CG. A method for determining the total respiratory exchange in man. J Physiol 1911: 42: 1-2.
    • (1911) J Physiol , vol.42 , pp. 1-2
    • Douglas, C.G.1
  • 13
    • 4244045287 scopus 로고    scopus 로고
    • Validity of a breath by breath gas exchange analysis system
    • Engebretson JE. Validity of a breath by breath gas exchange analysis system. Med Sci Sport Exerc 1998: 30(Suppl 5): S330.
    • (1998) Med Sci Sport Exerc , vol.30 , Issue.5 SUPPL.
    • Engebretson, J.E.1
  • 14
    • 0002865048 scopus 로고    scopus 로고
    • Quality assurance in exercise physiology laboratories
    • Gore CJ, ed. Champaign, IL: Human Kinetics
    • Gore CJ. Quality assurance in exercise physiology laboratories. In: Gore CJ, ed. Physiological testing for elite athletes. Champaign, IL: Human Kinetics, 2000.
    • (2000) Physiological Testing for Elite Athletes
    • Gore, C.J.1
  • 17
    • 4243965412 scopus 로고    scopus 로고
    • The comparison between three different respiratory gas analysers
    • Hiilloskorpi H, Manttari A, Pasanen M. The comparison between three different respiratory gas analysers. Med Sci Sports Exerc 2000: 31(Suppl 5): S354.
    • (2000) Med Sci Sports Exerc , vol.31 , Issue.5 SUPPL.
    • Hiilloskorpi, H.1    Manttari, A.2    Pasanen, M.3
  • 19
    • 0025322199 scopus 로고
    • A respiratory gas exchange simulator for routine calibration in metabolic studies
    • Huszczuk A, Whipp BJ, Wasserman K. A respiratory gas exchange simulator for routine calibration in metabolic studies. Eur Respir J 1990: 3: 465-468.
    • (1990) Eur Respir J , vol.3 , pp. 465-468
    • Huszczuk, A.1    Whipp, B.J.2    Wasserman, K.3
  • 20
    • 0003171309 scopus 로고
    • An evaluation of an automated system measurement of cardio respiratory function during exercise
    • Jackson AS, Hartung GH, Bradley PW. An evaluation of an automated system measurement of cardio respiratory function during exercise. Med Sci Sport Exerc 1983: 15(2): 144.
    • (1983) Med Sci Sport Exerc , vol.15 , Issue.2 , pp. 144
    • Jackson, A.S.1    Hartung, G.H.2    Bradley, P.W.3
  • 21
    • 26444491517 scopus 로고    scopus 로고
    • Equipment testing and validation assessment of fractional expired gasses and airflow by an ambulatory metabolic analyser
    • Jacobs PL. Equipment testing and validation assessment of fractional expired gasses and airflow by an ambulatory metabolic analyser. J Exerc Physiol 1999: 2(4): 1-14.
    • (1999) J Exerc Physiol , vol.2 , Issue.4 , pp. 1-14
    • Jacobs, P.L.1
  • 22
    • 0018562187 scopus 로고
    • Quality control of exercise test measurements
    • Jones NL, Kane JW. Quality control of exercise test measurements. Med Sci Sports 1979: 11(4): 368-372.
    • (1979) Med Sci Sports , vol.11 , Issue.4 , pp. 368-372
    • Jones, N.L.1    Kane, J.W.2
  • 23
    • 0020961706 scopus 로고
    • An evaluation of Beckman metabolic cart for measuring ventilation and aerobic requirements during exercise
    • Kannagi T, Bruce RA, Hossack KF. An evaluation of Beckman metabolic cart for measuring ventilation and aerobic requirements during exercise. J Cardiac Rehabil 1983: 3(1): 38-53.
    • (1983) J Cardiac Rehabil , vol.3 , Issue.1 , pp. 38-53
    • Kannagi, T.1    Bruce, R.A.2    Hossack, K.F.3
  • 24
    • 0020026151 scopus 로고
    • Biological variability in maximal aerobic power
    • Katch VL, Sady SS, Freedson P. Biological variability in maximal aerobic power. Med Sci Sports Exerc 1982: 14(1): 21-25.
    • (1982) Med Sci Sports Exerc , vol.14 , Issue.1 , pp. 21-25
    • Katch, V.L.1    Sady, S.S.2    Freedson, P.3
  • 25
  • 27
    • 4243326903 scopus 로고
    • Reproducibility between three metabolic systems and validation by Douglas bag method
    • La Mere VJ, Brown K, Wigglesworth JK, Edwards JE. Reproducibility between three metabolic systems and validation by Douglas bag method. Med Sci Sports Exerc 1993: 25(5): S9.
    • (1993) Med Sci Sports Exerc , vol.25 , Issue.5
    • La Mere, V.J.1    Brown, K.2    Wigglesworth, J.K.3    Edwards, J.E.4
  • 28
    • 0027615995 scopus 로고
    • Validity and reliability of the Cosmed K2 to measure oxygen uptake
    • Lothian F, Farrally MR, Mahoney C. Validity and reliability of the Cosmed K2 to measure oxygen uptake. Can J Appl Physiol 1993: 18(2): 197-206.
    • (1993) Can J Appl Physiol , vol.18 , Issue.2 , pp. 197-206
    • Lothian, F.1    Farrally, M.R.2    Mahoney, C.3
  • 29
    • 0034785831 scopus 로고    scopus 로고
    • Automated metabolic gas analysis systems: A review
    • Macfarlane D. Automated metabolic gas analysis systems: a review. Sports Med 2001: 31(12): 841-861.
    • (2001) Sports Med , vol.31 , Issue.12 , pp. 841-861
    • Macfarlane, D.1
  • 32
    • 0033912050 scopus 로고    scopus 로고
    • System of automated gas-exchange analysis for the investigation of metabolic processes
    • Midownik S, Carlton VA, Ferri E, Burda B, Melandez JA. System of automated gas-exchange analysis for the investigation of metabolic processes. J Appl Physiol 2000: 89: 373-378.
    • (2000) J Appl Physiol , vol.89 , pp. 373-378
    • Midownik, S.1    Carlton, V.A.2    Ferri, E.3    Burda, B.4    Melandez, J.A.5
  • 33
    • 0028104214 scopus 로고
    • Four commonly utilised metabolic systems fail to produce similar results during submaximal and maximal exercise
    • Miles DS, Cox MH, Verde TJ. Four commonly utilised metabolic systems fail to produce similar results during submaximal and maximal exercise. Sports Med Training Rehabil. 1994: 5: 189-198.
    • (1994) Sports Med Training Rehabil , vol.5 , pp. 189-198
    • Miles, D.S.1    Cox, M.H.2    Verde, T.J.3
  • 34
    • 0031858909 scopus 로고    scopus 로고
    • Quantitative methanol-burning lung model for validating gas-exchange measurements over wide ranges of FIO2
    • Miodownik S, Melandez J, Carlon VA, Burda B. Quantitative methanol-burning lung model for validating gas-exchange measurements over wide ranges of FIO2. J Appl Physiol 1998: 84: 2177-2182.
    • (1998) J Appl Physiol , vol.84 , pp. 2177-2182
    • Miodownik, S.1    Melandez, J.2    Carlon, V.A.3    Burda, B.4
  • 35
    • 0027401060 scopus 로고
    • Oxygen consumption using the K2 telemetry system and a metabolic cart
    • Peel C, Utsey C. Oxygen consumption using the K2 telemetry system and a metabolic cart. Med Sci Sports Exerc 1993: 25: 396-400.
    • (1993) Med Sci Sports Exerc , vol.25 , pp. 396-400
    • Peel, C.1    Utsey, C.2
  • 38
    • 0035007392 scopus 로고    scopus 로고
    • Validation of a computerized metabolic measurement system (Oxycon-Pro) during low and high intensity exercise
    • Rietjens GJ, Kuipers H, Kester AD, Keizer HA. Validation of a computerized metabolic measurement system (Oxycon-Pro) during low and high intensity exercise. Int J Sports Med 2001: 22(4): 291-294.
    • (2001) Int J Sports Med , vol.22 , Issue.4 , pp. 291-294
    • Rietjens, G.J.1    Kuipers, H.2    Kester, A.D.3    Keizer, H.A.4
  • 39
    • 84872637760 scopus 로고
    • Analyser for accurate estimation of respiratory gases in one-half cubic centimetre samples
    • Scholander PF. Analyser for accurate estimation of respiratory gases in one-half cubic centimetre samples. J Biol Chem 1947: 167: 235.
    • (1947) J Biol Chem , vol.167 , pp. 235
    • Scholander, P.F.1
  • 41
    • 0001847544 scopus 로고
    • Testing aerobic power
    • McDougall JD, Wenger HA, Green. HI, eds. Champaign, IL: Human Kinetics
    • Theoden JS. Testing aerobic power. In: McDougall JD, Wenger HA, Green. HI, eds. Physiological testing of the high performance athlete. Champaign, IL: Human Kinetics, 1991: 107-173.
    • (1991) Physiological Testing of the High Performance Athlete , pp. 107-173
    • Theoden, J.S.1
  • 42
    • 0028688522 scopus 로고
    • Validation of the Sensor medics (S2900Z) metabolic cart for paediatric exercise testing
    • Unnithan VB, Wilson J, Buchannan D, Timmons JA, Paton JY. Validation of the Sensor medics (S2900Z) metabolic cart for paediatric exercise testing. Canad J Appl Physiol 1994: 19(4): 472-479.
    • (1994) Canad J Appl Physiol , vol.19 , Issue.4 , pp. 472-479
    • Unnithan, V.B.1    Wilson, J.2    Buchannan, D.3    Timmons, J.A.4    Paton, J.Y.5
  • 43
    • 0024589699 scopus 로고
    • Automated systems for measurement of oxygen uptake during exercise testing
    • Versteeg PGA, Kipperluis GJ. Automated systems for measurement of oxygen uptake during exercise testing. Int J Sports Testing 1989: 10: 107-112.
    • (1989) Int J Sports Testing , vol.10 , pp. 107-112
    • Versteeg, P.G.A.1    Kipperluis, G.J.2
  • 47
    • 0023628720 scopus 로고
    • Turbine flowmeter Vs Fliesch pneumotachometer: A comparative study for exercise testing
    • Yeh MP, Adams TD, Gardner RM. Turbine flowmeter Vs Fliesch pneumotachometer: a comparative study for exercise testing. J Appl Physiol 1987: 63(3): 1289-1295.
    • (1987) J Appl Physiol , vol.63 , Issue.3 , pp. 1289-1295
    • Yeh, M.P.1    Adams, T.D.2    Gardner, R.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.