메뉴 건너뛰기




Volumn 81, Issue 6, 1996, Pages 2495-2499

Delay time adjustments to minimize errors in breath-by-breath measurement of V̇O2 during exercise

Author keywords

Equipment validation; Gas exchange; Human performance; Hyperpnea; Indirect calorimetry; Oxygen consumption

Indexed keywords

ADULT; ANALYTICAL ERROR; ARTICLE; BICYCLE ERGOMETRY; BREATH ANALYSIS; BREATHING RATE; EXERCISE; EXPIRED AIR; HUMAN; HUMAN EXPERIMENT; LUNG GAS EXCHANGE; LUNG MINUTE VOLUME; MALE; NORMAL HUMAN; OXYGEN CONSUMPTION; PNEUMOTACHYGRAPHY; PRIORITY JOURNAL; TIME;

EID: 0030482453     PISSN: 87507587     EISSN: None     Source Type: Journal    
DOI: 10.1152/jappl.1996.81.6.2495     Document Type: Article
Times cited : (59)

References (13)
  • 2
    • 0019785243 scopus 로고
    • Corrections for the response time and delay of mass spectrometers
    • Arieli, R., and H. D. Van Liew. Corrections for the response time and delay of mass spectrometers. J. Appl. Physiol. 51: 1417-1422, 1981.
    • (1981) J. Appl. Physiol. , vol.51 , pp. 1417-1422
    • Arieli, R.1    Van Liew, H.D.2
  • 3
    • 0003228076 scopus 로고
    • Evaluation of physical work capacity on the basis of tests
    • New York: McGraw-Hill, chapt. 10
    • Astrand, P., and K. Rodahl. Evaluation of physical work capacity on the basis of tests. In: Textbook of Work Physiology. New York: McGraw-Hill, 1977, chapt. 10, p. 331-365.
    • (1977) Textbook of Work Physiology , pp. 331-365
    • Astrand, P.1    Rodahl, K.2
  • 4
    • 0019782367 scopus 로고
    • Breath-by-breath measurement of true alveolar gas exchange
    • Beaver, W. L., N. LaMarra, and K. Wasserman. Breath-by-breath measurement of true alveolar gas exchange. J. Appl. Physiol. 51: 1662-1675, 1981.
    • (1981) J. Appl. Physiol. , vol.51 , pp. 1662-1675
    • Beaver, W.L.1    LaMarra, N.2    Wasserman, K.3
  • 5
    • 0015547883 scopus 로고
    • On-line computer analysis and breath-by-breath graphical display of exercise function tests
    • Beaver, W. L., K. Wasserman, and B. J. Whipp. On-line computer analysis and breath-by-breath graphical display of exercise function tests. J. Appl. Physiol. 34: 128-132, 1973.
    • (1973) J. Appl. Physiol. , vol.34 , pp. 128-132
    • Beaver, W.L.1    Wasserman, K.2    Whipp, B.J.3
  • 6
    • 0025869396 scopus 로고
    • Alignment of ventilation and gas fraction for breath-by-breath respiratory gas exchange calculations in exercise
    • Hughson, R. L., D. R. Northey, H. C. Xing, B. H. Dietrich, and J. E. Cochrane. Alignment of ventilation and gas fraction for breath-by-breath respiratory gas exchange calculations in exercise. Comput. Biomed. Res. 24: 118-128, 1991.
    • (1991) Comput. Biomed. Res. , vol.24 , pp. 118-128
    • Hughson, R.L.1    Northey, D.R.2    Xing, H.C.3    Dietrich, B.H.4    Cochrane, J.E.5
  • 7
    • 0025322199 scopus 로고
    • A respiratory gas exchange simulator for routine calibration in metabolic studies
    • Huszczuk, A., B. J. Whipp, and K. Wasserman. A respiratory gas exchange simulator for routine calibration in metabolic studies. Eur. Respir. J. 3: 465-468, 1990.
    • (1990) Eur. Respir. J. , vol.3 , pp. 465-468
    • Huszczuk, A.1    Whipp, B.J.2    Wasserman, K.3
  • 13
    • 0028277640 scopus 로고
    • Behind the scenes of cardiopulmonary exercise testing
    • Zeballos, R. J., and I. M. Weisman. Behind the scenes of cardiopulmonary exercise testing. Clin. Chest Med. 15: 193-213, 1994.
    • (1994) Clin. Chest Med. , vol.15 , pp. 193-213
    • Zeballos, R.J.1    Weisman, I.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.