1
-
-
0029244079
-
The history and development of the implantable hearing aid
-
R.L. Goode, M.L. Rosenbaum, and A.J. Maniglia, "The history and development of the implantable hearing aid," Otolaryngologic Clinics of North America, vol.28, no.1, pp.1-16, 1995.
-
(1995)
Otolaryngologic Clinics of North America
, vol.28
, Issue.1
, pp. 1-16
-
-
Goode, R.L.1
Rosenbaum, M.L.2
Maniglia, A.J.3
-
3
-
-
0141693330
-
Current status and critical reflections on implantable hearing aids
-
K.B. Huttenbrink, "Current status and critical reflections on implantable hearing aids," American Journal of Otology, vol.20, pp.409-415, 1999.
-
(1999)
American Journal of Otology
, vol.20
, pp. 409-415
-
-
Huttenbrink, K.B.1
-
4
-
-
0031006617
-
Mechanical, acoustic and electromagnetic evaluation of semiimplantable middle ear hearing device (SIMEHD)
-
H.A. Abbass, M. Kane, S. Garverick, W.H. Ko, and A.J. Maniglia, "Mechanical, acoustic and electromagnetic evaluation of semiimplantable middle ear hearing device (SIMEHD)," Ear, Nose & Throat Journal, vol.76, no.5, pp.321-327, 1997.
-
(1997)
Ear, Nose & Throat Journal
, vol.76
, Issue.5
, pp. 321-327
-
-
Abbass, H.A.1
Kane, M.2
Garverick, S.3
Ko, W.H.4
Maniglia, A.J.5
-
5
-
-
0028938696
-
Engineering principles of mechanical stimulation of the middle ear
-
Feb.
-
W. Ko, W. Zhu, and A. Maniglia, "Engineering principles of mechanical stimulation of the middle ear," Otolaryngoligic Clinics of North America, vol.28, no 1, pp.29-41, Feb. 1995.
-
(1995)
Otolaryngoligic Clinics of North America
, vol.28
, Issue.1
, pp. 29-41
-
-
Ko, W.1
Zhu, W.2
Maniglia, A.3
-
6
-
-
0028924914
-
Contactless semi-implantable electromagnetic middle ear device for treatment of sensorineural hearing loss
-
A.J. Maniglia and W.H. Ko, "Contactless semi-implantable electromagnetic middle ear device for treatment of sensorineural hearing loss," Otolaryngologic Clinics of North America, vol.28, no.1, pp. 107-120, 1995.
-
(1995)
Otolaryngologic Clinics of North America
, vol.28
, Issue.1
, pp. 107-120
-
-
Maniglia, A.J.1
Ko, W.H.2
-
7
-
-
0028928707
-
Ongoing investigation into an implantable electromagnetic hearing aid for moderate to severe sensorineural hearing loss
-
Feb.
-
M. Fredrickson, M. Coticchia, and S. Khosla, "Ongoing investigation into an implantable electromagnetic hearing aid for moderate to severe sensorineural hearing loss," Otolaryngoligic Clinics of North America, vol.28, no 1, pp.107-120, Feb. 1995.
-
(1995)
Otolaryngoligic Clinics of North America
, vol.28
, Issue.1
, pp. 107-120
-
-
Fredrickson, M.1
Coticchia, M.2
Khosla, S.3
-
8
-
-
1242350251
-
Design consideration for a contactless electromagnetic transducer for implantable hearing aids
-
Nov.
-
M. Rompis, C. Kuhn, M. Affolter, U. Brugger, and R. Hausler, "Design consideration for a contactless electromagnetic transducer for implantable hearing aids," Proc. 20th Annual International Conference of the IEEE-EMBS, vol.20, no.6, pp.3137-3176, Nov. 1998.
-
(1998)
Proc. 20th Annual International Conference of the IEEE-EMBS
, vol.20
, Issue.6
, pp. 3137-3176
-
-
Rompis, M.1
Kuhn, C.2
Affolter, M.3
Brugger, U.4
Hausler, R.5
-
9
-
-
0028950182
-
Partially implantable hearing aid using piezoelectric ceramic ossicular vibrator: Results of the implant operation and assessment of the hearing afforded by the device
-
Feb.
-
N. Yanagihara, K. Gyo, and Y. Hinohira, "Partially implantable hearing aid using piezoelectric ceramic ossicular vibrator: Results of the implant operation and assessment of the hearing afforded by the device," Otolaryngologic Clinics of North America, vol.28, pp.85-98, Feb. 1995.
-
(1995)
Otolaryngologic Clinics of North America
, vol.28
, pp. 85-98
-
-
Yanagihara, N.1
Gyo, K.2
Hinohira, Y.3
-
10
-
-
0030996809
-
Surgical rehabilitation of deafness with partially implantable hearing aids using piezoelectric ceramic bimorpli ossicular vibrator
-
N. Yanagihara, Y. Hinohira, and K. Gyo, "Surgical rehabilitation of deafness with partially implantable hearing aids using piezoelectric ceramic bimorpli ossicular vibrator," Auris Nasus Larynx, vol.24, pp.91-98, 1997.
-
(1997)
Auris Nasus Larynx
, vol.24
, pp. 91-98
-
-
Yanagihara, N.1
Hinohira, Y.2
Gyo, K.3
-
11
-
-
0028924914
-
Contactless semiimplantable electromagnetic middle ear device for the treatment of sensorineural hearing loss: Short term and long term animal experiments
-
Feb.
-
A. Maniglia, W. Ko, L. Rosenbaum, T. Falk, W. Zhu, N. Frenz, J. Werning, J. Masin, A. Stein, and A. Sabri, "Contactless semiimplantable electromagnetic middle ear device for the treatment of sensorineural hearing loss: Short term and long term animal experiments," Otolaryngologic Clinics of North America, vol.28, pp. 121-140, Feb. 1995.
-
(1995)
Otolaryngologic Clinics of North America
, vol.28
, pp. 121-140
-
-
Maniglia, A.1
Ko, W.2
Rosenbaum, L.3
Falk, T.4
Zhu, W.5
Frenz, N.6
Werning, J.7
Masin, J.8
Stein, A.9
Sabri, A.10
-
12
-
-
0029272962
-
A microminiature electromagnetic middle-ear implant hearing device
-
W. Affane and T.S. Birch, "A microminiature electromagnetic middle-ear implant hearing device," Sens. Actuators A, Phys., vol.A46-47, pp.584-587, 1995.
-
(1995)
Sens. Actuators A, Phys.
, vol.A46-47
, pp. 584-587
-
-
Affane, W.1
Birch, T.S.2
-
13
-
-
0033989333
-
The effect of the floating mass transducer in hearing sensitivity
-
March
-
F. Snik and W. Cremers, "The effect of the floating mass transducer in hearing sensitivity," American Journal of Otolarlyngology, vol.21, no.1, pp.42-48, March 2000.
-
(2000)
American Journal of Otolarlyngology
, vol.21
, Issue.1
, pp. 42-48
-
-
Snik, F.1
Cremers, W.2
-
14
-
-
0030887913
-
Acute human trial of the floating mass transducer
-
April
-
A. Tjellstrom and C. Luetje, "Acute human trial of the floating mass transducer," Ear, Nose & Throat Journal, vol.76, no.4, pp.204-211, April 1997.
-
(1997)
Ear, Nose & Throat Journal
, vol.76
, Issue.4
, pp. 204-211
-
-
Tjellstrom, A.1
Luetje, C.2
-
15
-
-
12644268256
-
Effect of magnetic resonance imaging on a new electromagnetic implantable middle ear hearing device
-
July
-
S. Hunyadi and W. Werning, "Effect of magnetic resonance imaging on a new electromagnetic implantable middle ear hearing device," American Journal of Otology, vol.18, no.3, pp.328-331, July 1997.
-
(1997)
American Journal of Otology
, vol.18
, Issue.3
, pp. 328-331
-
-
Hunyadi, S.1
Werning, W.2
-
16
-
-
0036614570
-
Proposal and evaluation of vibration transducer with minimal magnetic field interference for use in IME system by in-vitro experiment
-
June
-
B.S. Song, T.Y. Jung, S.P. Chae, M.N. Kim, and J.H. Cho, "Proposal and evaluation of vibration transducer with minimal magnetic field interference for use in IME system by in-vitro experiment," IEICE Trans. Electron., vol.E85-C, no.6, pp. 1374-1377, June 2002.
-
(2002)
IEICE Trans. Electron.
, vol.E85-C
, Issue.6
, pp. 1374-1377
-
-
Song, B.S.1
Jung, T.Y.2
Chae, S.P.3
Kim, M.N.4
Cho, J.H.5
-
18
-
-
0029403706
-
Electromagnetic actuator behavior analysis using finite element and parameterization methods
-
K. Srairi and M. Feliachi, "Electromagnetic actuator behavior analysis using finite element and parameterization methods," IEEE Trans. Magn., vol.31, no.6, pp.3497-3499, 1995.
-
(1995)
IEEE Trans. Magn.
, vol.31
, Issue.6
, pp. 3497-3499
-
-
Srairi, K.1
Feliachi, M.2
-
19
-
-
0000034495
-
Analytical and FEM modeling of piezoresistive silicon accelerometers: Prediction and limitations compared to experiments
-
T. Tschan, N.D. Rooji, and A. Bezinge, "Analytical and FEM modeling of piezoresistive silicon accelerometers: Prediction and limitations compared to experiments," Sens. Mater., vol.3, pp.189-195, 1993.
-
(1993)
Sens. Mater.
, vol.3
, pp. 189-195
-
-
Tschan, T.1
Rooji, N.D.2
Bezinge, A.3
|