메뉴 건너뛰기




Volumn 18, Issue 3, 1997, Pages 328-331

Effect of magnetic resonance imaging on a new electromagnetic implantable middle ear hearing device

Author keywords

Bone cement; Cochlear implants; Disruption; Magnetic resonance imaging; Middle ear; Neodymium iron boron magnet

Indexed keywords

ARTICLE; CONTROLLED STUDY; ELECTROMAGNETIC FIELD; HEARING AID; HUMAN; HUMAN TISSUE; MAGNET; MIDDLE EAR; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PROSTHESIS LOOSENING;

EID: 12644268256     PISSN: 01929763     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (18)

References (13)
  • 1
    • 0023814837 scopus 로고
    • High-field-strength MR imaging and metallic biomedical implants: An ex vivo evaluation of deflection forces
    • Shellock F, Crues JV. High-field-strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. Am J Radiol 1988;151:389-92.
    • (1988) Am J Radiol , vol.151 , pp. 389-392
    • Shellock, F.1    Crues, J.V.2
  • 3
    • 0025186079 scopus 로고
    • Further studies on the effects of magnetic resonance imaging fields on middle ear implants
    • Applebaum EL, Valvassori GE. Further studies on the effects of magnetic resonance imaging fields on middle ear implants. Ann Otol Rhinol Laryngol 1990;99:801-4.
    • (1990) Ann Otol Rhinol Laryngol , vol.99 , pp. 801-804
    • Applebaum, E.L.1    Valvassori, G.E.2
  • 4
    • 0026021270 scopus 로고
    • Cochlear implants as a contraindication to magnetic resonance imaging
    • Portnoy WM, Mattucci K. Cochlear implants as a contraindication to magnetic resonance imaging. Ann Otol Rhinol Laryngol 1991;100: 195-7.
    • (1991) Ann Otol Rhinol Laryngol , vol.100 , pp. 195-197
    • Portnoy, W.M.1    Mattucci, K.2
  • 5
    • 0026556962 scopus 로고
    • The effect of magnetic resonance imagers on implanted neurostimulators
    • Gleason CA, Kuala NF, Hricak H, et al. The effect of magnetic resonance imagers on implanted neurostimulators. PACE Pacing Clin Electrophysiol 1992;15:81-94.
    • (1992) PACE Pacing Clin Electrophysiol , vol.15 , pp. 81-94
    • Gleason, C.A.1    Kuala, N.F.2    Hricak, H.3
  • 7
    • 0027475037 scopus 로고
    • Case report: Nuclear magnetic resonance imaging in a patient with a pacemaker
    • Inbar S, Larson J, Burt T, et al. Case report: nuclear magnetic resonance imaging in a patient with a pacemaker. Am J Med Sci 1993;305: 174-5.
    • (1993) Am J Med Sci , vol.305 , pp. 174-175
    • Inbar, S.1    Larson, J.2    Burt, T.3
  • 8
    • 0025978746 scopus 로고
    • Metallic otologic implants: In vitro assessment of ferromagnetism at 1.5 T
    • Shellock FG, Schatz CJ. Metallic otologic implants: in vitro assessment of ferromagnetism at 1.5 T. AJNR Am J Neuroradiol 1991;12: 279-81.
    • (1991) AJNR Am J Neuroradiol , vol.12 , pp. 279-281
    • Shellock, F.G.1    Schatz, C.J.2
  • 9
    • 0023253185 scopus 로고
    • Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers
    • Hayes DL, Holmes DR, Gray JE. Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers. J Am Coll Cardiol 1987;10:782-6.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 782-786
    • Hayes, D.L.1    Holmes, D.R.2    Gray, J.E.3
  • 10
    • 0028924914 scopus 로고
    • Contactless semi-implantable electromagnetic middle ear device for the treatment of sensorineural hearing loss: Short-term and long-term animal experiments
    • Maniglia AJ, Ko WH, Rosenbaum M, et al. Contactless semi-implantable electromagnetic middle ear device for the treatment of sensorineural hearing loss: short-term and long-term animal experiments. Otolaryngol Clin North Am 1995;28:121-40.
    • (1995) Otolaryngol Clin North Am , vol.28 , pp. 121-140
    • Maniglia, A.J.1    Ko, W.H.2    Rosenbaum, M.3
  • 11
    • 0028961012 scopus 로고
    • Biomechanical assessment of a new adhesive bone cement for otologic surgery
    • Werning JW, Maniglia AJ, Anderson JM. Biomechanical assessment of a new adhesive bone cement for otologic surgery. Am J Otol 1995;16:269-76.
    • (1995) Am J Otol , vol.16 , pp. 269-276
    • Werning, J.W.1    Maniglia, A.J.2    Anderson, J.M.3
  • 12
    • 0030909319 scopus 로고    scopus 로고
    • A new adhesive bonding material for the cementation of implantable devices in otologic surgery
    • Maniglia AJ, Nakabayashi N, Paparella MM, et al. A new adhesive bonding material for the cementation of implantable devices in otologic surgery. Am J Otol 1997; 18:322-7.
    • (1997) Am J Otol , vol.18 , pp. 322-327
    • Maniglia, A.J.1    Nakabayashi, N.2    Paparella, M.M.3
  • 13
    • 0029128643 scopus 로고
    • Effects of magnetic resonance imaging on implantable permanent magnets
    • Schneider ML, Walker GB, Dormer KJ. Effects of magnetic resonance imaging on implantable permanent magnets. Am J Otol 1995;16:687-9.
    • (1995) Am J Otol , vol.16 , pp. 687-689
    • Schneider, M.L.1    Walker, G.B.2    Dormer, K.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.