-
1
-
-
0028158773
-
Update on clinical significance of coagulase-negative staphylococci
-
Kloos WE, Bannermann TL. Update on clinical significance of coagulase-negative staphylococci. Clin Microbiol Rev 1994; 7: 117-140.
-
(1994)
Clin. Microbiol. Rev.
, vol.7
, pp. 117-140
-
-
Kloos, W.E.1
Bannermann, T.L.2
-
2
-
-
0032031106
-
Staphylococcus aureus and coagulase-negative staphylococci from blood stream infections: Frequency of occurrence, antimicrobial susceptibility, and molecular (mecA) characterization of oxacillin resistance in the SCOPE program
-
Marshall SA, Wilke WW, Pfaller MA, Jones RN. Staphylococcus aureus and coagulase-negative staphylococci from blood stream infections: frequency of occurrence, antimicrobial susceptibility, and molecular (mecA) characterization of oxacillin resistance in the SCOPE program. Diagn Microbiol Infect Dis 1998; 30: 205-212.
-
(1998)
Diagn. Microbiol. Infect. Dis.
, vol.30
, pp. 205-212
-
-
Marshall, S.A.1
Wilke, W.W.2
Pfaller, M.A.3
Jones, R.N.4
-
3
-
-
0036841516
-
Pathogenesis of infections due to coagulase-negative staphylococci
-
von Eiff C, Peters G, Heilmann C. Pathogenesis of infections due to coagulase-negative staphylococci. Lancet Infect Dis 2002; 2: 677-685.
-
(2002)
Lancet Infect. Dis.
, vol.2
, pp. 677-685
-
-
von Eiff, C.1
Peters, G.2
Heilmann, C.3
-
4
-
-
0023794325
-
Methicillin-resistant staphylococci
-
Chambers HF. Methicillin-resistant staphylococci. Clin Microbiol Rev 1988; 1: 173-186.
-
(1988)
Clin. Microbiol. Rev.
, vol.1
, pp. 173-186
-
-
Chambers, H.F.1
-
5
-
-
0025145843
-
Detection of methicillin resistance in staphylococci by using a DNA probe
-
Archer GL, Pennell E. Detection of methicillin resistance in staphylococci by using a DNA probe. Antimicrob Agents Chemother 1990; 34: 1720-1724.
-
(1990)
Antimicrob. Agents Chemother.
, vol.34
, pp. 1720-1724
-
-
Archer, G.L.1
Pennell, E.2
-
7
-
-
0030824628
-
Evaluation of different methods for the detection of methicillin-resistance in coagulase-negative staphylococci
-
Jarløv JO, Bosch-Sørensen C, Espersen F, Mortensen I, Hougaard DM, Rosdahl VT. Evaluation of different methods for the detection of methicillin-resistance in coagulase-negative staphylococci. J Antimicrob Chemother 1997; 40: 241-249.
-
(1997)
J. Antimicrob. Chemother.
, vol.40
, pp. 241-249
-
-
Jarløv, J.O.1
Bosch-Sørensen, C.2
Espersen, F.3
Mortensen, I.4
Hougaard, D.M.5
Rosdahl, V.T.6
-
8
-
-
0028903795
-
Revised interpretation of oxacillin MICs for Staphylococcus epidermidis based on mecA detection
-
McDonald CL, Maher WE, Fass RJ. Revised interpretation of oxacillin MICs for Staphylococcus epidermidis based on mecA detection. Antimicrob Agents Chemother 1995; 39: 982-984.
-
(1995)
Antimicrob. Agents Chemother.
, vol.39
, pp. 982-984
-
-
McDonald, C.L.1
Maher, W.E.2
Fass, R.J.3
-
9
-
-
0025983233
-
Genotypic identification of methicillin-resistant coagulase-negative staphylococci by polymerase chain reaction
-
Predari SC, Ligozzi M, Fontana R. Genotypic identification of methicillin-resistant coagulase-negative staphylococci by polymerase chain reaction. Antimicrob Agents Chemother 1991; 35: 2568-2573.
-
(1991)
Antimicrob. Agents Chemother.
, vol.35
, pp. 2568-2573
-
-
Predari, S.C.1
Ligozzi, M.2
Fontana, R.3
-
10
-
-
0031043424
-
Methicillin susceptibility testing of staphylococci by E test and comparison with agar dilution and mecA detection
-
Weller TM, Crook DW, Croow MR, Ibrahim W, Pennington TH, Selkon JB. Methicillin susceptibility testing of staphylococci by E test and comparison with agar dilution and mecA detection. J Antimicrob Chemother 1997; 39: 251-253.
-
(1997)
J. Antimicrob. Chemother.
, vol.39
, pp. 251-253
-
-
Weller, T.M.1
Crook, D.W.2
Croow, M.R.3
Ibrahim, W.4
Pennington, T.H.5
Selkon, J.B.6
-
11
-
-
0032702323
-
Methods for improved detection of oxacillin resistance in coagulase negative staphylococci: Results of a multicenter study
-
Tenover FC, Jones RN, Swenson JM et al. Methods for improved detection of oxacillin resistance in coagulase negative staphylococci: results of a multicenter study. J Clin Microbiol 1999; 37: 4051-4058.
-
(1999)
J. Clin. Microbiol.
, vol.37
, pp. 4051-4058
-
-
Tenover, F.C.1
Jones, R.N.2
Swenson, J.M.3
-
12
-
-
0032772504
-
Comparison of susceptibility testing methods with mecA gene analysis for determining oxacillin (methicillin) resistance in clinical isolates of Staphylococcus aureus and coagulase-negative Staphylococcus spp
-
Kohner P, Uhl J, Kolbert C, Persing D, Cockerill F. Comparison of susceptibility testing methods with mecA gene analysis for determining oxacillin (methicillin) resistance in clinical isolates of Staphylococcus aureus and coagulase-negative Staphylococcus spp. J Clin Microbiol 1999; 37: 2952-2961.
-
(1999)
J. Clin. Microbiol.
, vol.37
, pp. 2952-2961
-
-
Kohner, P.1
Uhl, J.2
Kolbert, C.3
Persing, D.4
Cockerill, F.5
-
13
-
-
0033971885
-
Comparison of PCR detection of mecA with methicillin and oxacillin disc susceptibility testing in coagulase-negative staphylococci
-
Graham JC, Murphy OM, Stewart D, Kearns AM, Galloway A, Freeman R. Comparison of PCR detection of mecA with methicillin and oxacillin disc susceptibility testing in coagulase-negative staphylococci. J Antimicrob Chemother 2000; 45: 111-113.
-
(2000)
J. Antimicrob. Chemother.
, vol.45
, pp. 111-113
-
-
Graham, J.C.1
Murphy, O.M.2
Stewart, D.3
Kearns, A.M.4
Galloway, A.5
Freeman, R.6
-
14
-
-
0033950406
-
Correlation of oxacillin MIC with mecA gene carriage in coagulase-negative staphylococci
-
Hussain Z, Stoakes L, Massey V et al. Correlation of oxacillin MIC with mecA gene carriage in coagulase-negative staphylococci. J Clin Microbiol 2000; 38: 752-754.
-
(2000)
J. Clin. Microbiol.
, vol.38
, pp. 752-754
-
-
Hussain, Z.1
Stoakes, L.2
Massey, V.3
-
15
-
-
0034884505
-
Correlation between genotype and phenotypic categorization of staphylococci based in methicillin susceptibility and resistance
-
Gradelski E, Valera L, Aleksunes L, Bonner D, Fung-Tomc J. Correlation between genotype and phenotypic categorization of staphylococci based in methicillin susceptibility and resistance. J Clin Microbiol 2001; 39: 2961-2963.
-
(2001)
J. Clin. Microbiol.
, vol.39
, pp. 2961-2963
-
-
Gradelski, E.1
Valera, L.2
Aleksunes, L.3
Bonner, D.4
Fung-Tomc, J.5
-
16
-
-
0036275082
-
Agar diffusion, agar dilution, Etest, and agar screening test in the detection of methicillin resistance in staphylococci
-
Rowe F, Superti SV, Scheibe RM, Dias CG. Agar diffusion, agar dilution, Etest, and agar screening test in the detection of methicillin resistance in staphylococci. Diagn Microbiol Infect Dis 2002; 43: 45-48.
-
(2002)
Diagn. Microbiol. Infect. Dis.
, vol.43
, pp. 45-48
-
-
Rowe, F.1
Superti, S.V.2
Scheibe, R.M.3
Dias, C.G.4
-
17
-
-
0037721186
-
-
National Committee for Clinical Laboratory Standards. M100-S10. Wayne, PA: NCCLS
-
National Committee for Clinical Laboratory Standards. Performance standards for antimicrobial susceptibility testing. M100-S10. Wayne, PA: NCCLS, 2001.
-
(2001)
Performance Standards for Antimicrobial Susceptibility Testing
-
-
-
18
-
-
17444449803
-
Susceptibility testing of bacteria and fungi
-
Report from 'The Norwegian Working Group on Antibiotics'
-
Bergan T, Bruun JN, Digranes A, Lingaas E, Melby KK, Sander J. Susceptibility testing of bacteria and fungi. Report from 'The Norwegian Working Group on Antibiotics'. Scand J Infect Dis 1997; 103(suppl): S1-S36.
-
(1997)
Scand. J. Infect. Dis.
, vol.103
, Issue.SUPPL.
-
-
Bergan, T.1
Bruun, J.N.2
Digranes, A.3
Lingaas, E.4
Melby, K.K.5
Sander, J.6
-
19
-
-
0026486917
-
Accuracy of the E test for determining antimicrobial susceptibilities of staphylococci, enterococci, Campylobacter jejuni, and Gram-negative bacteria resistant to antimicrobial agents
-
Huang MB, Baker CN, Banerjee S, Tenover FC. Accuracy of the E test for determining antimicrobial susceptibilities of staphylococci, enterococci, Campylobacter jejuni, and Gram-negative bacteria resistant to antimicrobial agents. J Clin Microbiol 1992; 30: 3243-3248.
-
(1992)
J. Clin. Microbiol.
, vol.30
, pp. 3243-3248
-
-
Huang, M.B.1
Baker, C.N.2
Banerjee, S.3
Tenover, F.C.4
-
20
-
-
0031963864
-
Comparison of ATB Staph, Rapid ATB Staph, Vitek, and E-test methods for detection of oxacillin heteroresistance in staphylococci possessing mecA
-
Frebourg NB, Nouet D, Lemée L, Martin E, Lemeland JF. Comparison of ATB Staph, Rapid ATB Staph, Vitek, and E-test methods for detection of oxacillin heteroresistance in staphylococci possessing mecA. J Clin Microbiol 1998; 36: 52-57.
-
(1998)
J. Clin. Microbiol.
, vol.36
, pp. 52-57
-
-
Frebourg, N.B.1
Nouet, D.2
Lemée, L.3
Martin, E.4
Lemeland, J.F.5
|