메뉴 건너뛰기




Volumn 25, Issue 9, 2003, Pages 789-794

Intramedullary nails: Some design features of the distal end

Author keywords

Finite element method; Fractured femur; Intramedullary nails; Proximal femoral nails

Indexed keywords

ELASTICITY; FRACTURE; MATERIALS SCIENCE; PRESSURE MEASUREMENT; STIFFNESS; STRESS ANALYSIS;

EID: 2642510943     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4533(03)00098-5     Document Type: Article
Times cited : (16)

References (12)
  • 2
    • 0031808886 scopus 로고    scopus 로고
    • Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures
    • Hardy D.C.R., Descamps P.Y., Krallis P., Fabeck L., Smets P., Bertens C.L., Delince P.E. Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. J. Bone Jt. Surg. 80-A:(5):1998;618-630
    • (1998) J. Bone Jt. Surg. , vol.80 , Issue.5 , pp. 618-630
    • Hardy, D.C.R.1    Descamps, P.Y.2    Krallis, P.3    Fabeck, L.4    Smets, P.5    Bertens, C.L.6    Delince, P.E.7
  • 3
    • 0031925810 scopus 로고    scopus 로고
    • Cutting-out of the lag screw after internal fixation with the Asiatic Gamma Nail
    • Kawaguchi S., Swada K., Nabeta Y. Cutting-out of the lag screw after internal fixation with the Asiatic Gamma Nail. Injury. 29:(1):1998;47-53
    • (1998) Injury , vol.29 , Issue.1 , pp. 47-53
    • Kawaguchi, S.1    Swada, K.2    Nabeta, Y.3
  • 4
    • 0028920150 scopus 로고
    • Prevention of fracture at the distal locking site of the Gamma Nail
    • Lacroix H., Arwert H., Snijders C.J., Fontijne W.P.J. Prevention of fracture at the distal locking site of the Gamma Nail. J. Bone Jt. Surg. 77-B:(2):1995;274-276
    • (1995) J. Bone Jt. Surg. , vol.77 , Issue.2 , pp. 274-276
    • Lacroix, H.1    Arwert, H.2    Snijders, C.J.3    Fontijne, W.P.J.4
  • 6
    • 0025073198 scopus 로고
    • New design of hip prosthesis using carbon fibre reinforced composite
    • Shirandami H., Esat I.I. New design of hip prosthesis using carbon fibre reinforced composite. J. Biomed. Eng. 12:(1):1990;19-22
    • (1990) J. Biomed. Eng. , vol.12 , Issue.1 , pp. 19-22
    • Shirandami, H.1    Esat, I.I.2
  • 8
    • 0029248460 scopus 로고
    • Failure of the Gamma Nail in a highly unstable proximal femur fracture: Report of four cases encountered in the Netherlands
    • Van den Brink W.A., Janssen I.M.C. Failure of the Gamma Nail in a highly unstable proximal femur fracture: report of four cases encountered in The Netherlands. J. Orth. Trauma. 9:(1):1995;53-56
    • (1995) J. Orth. Trauma , vol.9 , Issue.1 , pp. 53-56
    • Van Den Brink, W.A.1    Janssen, I.M.C.2
  • 9
    • 0032216423 scopus 로고    scopus 로고
    • Finite element analysis of a Gamma Nail within a fractured femur
    • Wang C.J., Yettram A.L., Yao M.S., Procter P. Finite element analysis of a Gamma Nail within a fractured femur. Med. Eng. Phys. 20:1998;677-683
    • (1998) Med. Eng. Phys. , vol.20 , pp. 677-683
    • Wang, C.J.1    Yettram, A.L.2    Yao, M.S.3    Procter, P.4
  • 10
    • 0035099148 scopus 로고    scopus 로고
    • Intramedullary femoral nails: One or two lag screws? a preliminary study
    • Wang C.J., Brown C.J., Yettram A.L., Procter P. Intramedullary femoral nails: one or two lag screws? A preliminary study. Med. Eng. Phys. 22:2000;613-624
    • (2000) Med. Eng. Phys. , vol.22 , pp. 613-624
    • Wang, C.J.1    Brown, C.J.2    Yettram, A.L.3    Procter, P.4
  • 11
    • 4243545403 scopus 로고    scopus 로고
    • University of Vienna, Medical School, Trauma Center.
    • Wozasek GE, Radler C, Vecsei V. Gamma Nail failure. University of Vienna, Medical School, Trauma Center. 1997. Available: http://www.akh-wien.ac. atlunfall/casefcase%20G-Nail.html.
    • (1997) Gamma Nail Failure
    • Wozasek, G.E.1    Radler, C.2    Vecsei, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.