Volumn 405, Issue , 2002, Pages 277-286

Biomechanical evaluation of the proximal femoral nail

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BIOMECHANICS; BONE DENSITY; BONE SCREW; CADAVER; CLINICAL ARTICLE; EVALUATION; FEMALE; FEMUR FRACTURE; FEMUR NECK; HUMAN; IMPLANT; INTRAMEDULLARY NAILING; JOINT STABILITY; MALE; PRIORITY JOURNAL; STRESS FRACTURE; WEIGHT BEARING;

EID: 0036908832     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/00003086-200212000-00035     Document Type: Article
Times cited : (38)

References (8)
  • 1
    • 0031728467 scopus 로고    scopus 로고
    • Belastbahrkeit von osteosynthesen bei instabilen per- und subtrochanteren femurfrakturen
    • Götze B, Bonnaire F, Weise K, Friedl HP: Belastbahrkeit von osteosynthesen bei instabilen per- und subtrochanteren femurfrakturen. Aktuelle Traumatol 28:197-204, 1998.
    • (1998) Aktuelle Traumatol , vol.28 , pp. 197-204
    • Götze, B.1    Bonnaire, F.2    Weise, K.3    Friedl, H.P.4
  • 2
    • 0345451574 scopus 로고    scopus 로고
    • Failure of femoral head fixation: A cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw
    • Haynes RC, Pöll RG, Miles AW, Weston RB: Failure of femoral head fixation: A cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw. Injury 28:337-341, 1997.
    • (1997) Injury , vol.28 , pp. 337-341
    • Haynes, R.C.1    Pöll, R.G.2    Miles, A.W.3    Weston, R.B.4
  • 3
    • 1642551039 scopus 로고    scopus 로고
    • Photoelastic stress measurement of the proximal femur
    • Huber SM, Heining SM, Euler E: Photoelastic stress measurement of the proximal femur. J Bone Joint Surg 79B:166, 1997.
    • (1997) J Bone Joint Surg , vol.79 B , pp. 166
    • Huber, S.M.1    Heining, S.M.2    Euler, E.3
  • 4
    • 0028826494 scopus 로고
    • Rotational instability of trochanteric femoral fractures secured with the dynamic hip screw: A radiological analysis
    • Lustenberger A, Bekic J, Ganz R: [Rotational instability of trochanteric femoral fractures secured with the dynamic hip screw: A radiological analysis]. Unfallchirurg 98:514-517, 1995.
    • (1995) Unfallchirurg , vol.98 , pp. 514-517
    • Lustenberger, A.1    Bekic, J.2    Ganz, R.3
  • 6
    • 4243742359 scopus 로고    scopus 로고
    • PFN versus DHS/DCS pour les fractures de la région trochantérienne: Etude comparative prospective randomisée
    • Saudan M, Lubecke-Wolff A, Sadowski C, Riand N, Hoffmeyer P: PFN versus DHS/DCS pour les fractures de la région trochantérienne: Etude comparative prospective randomisée. Schweiz Med Wochenschr 129(Suppl):3, 1999.
    • (1999) Schweiz Med Wochenschr , vol.129 , Issue.SUPPL. , pp. 3
    • Saudan, M.1    Lubecke-Wolff, A.2    Sadowski, C.3    Riand, N.4    Hoffmeyer, P.5
  • 7
    • 0031836817 scopus 로고    scopus 로고
    • Die versorgung instabiler per- und subtrochantärer femurfrakturen mit dem proximalen femurnagel (PFN)
    • Schwab E, Höntzsch K, Weise K: Die versorgung instabiler per- und subtrochantärer femurfrakturen mit dem proximalen femurnagel (PFN). Aktuelle Traumatol 28:56-60, 1999.
    • (1999) Aktuelle Traumatol , vol.28 , pp. 56-60
    • Schwab, E.1    Höntzsch, K.2    Weise, K.3
  • 8
    • 0033034509 scopus 로고    scopus 로고
    • The AO/ASIF-proximal femoral nail (PFN): A new device for the treatment of unstable proximal femoral fractures
    • Simmermacher RK, Bosch AM, Van der Werken C: The AO/ASIF-proximal femoral nail (PFN): A new device for the treatment of unstable proximal femoral fractures. Injury 30:327-332, 1999.
    • (1999) Injury , vol.30 , pp. 327-332
    • Simmermacher, R.K.1    Bosch, A.M.2    Van der Werken, C.3