메뉴 건너뛰기




Volumn 22, Issue 4, 2005, Pages 451-460

Endovascular interventional MRI

Author keywords

Endovascular devices, Cardiac MRI, MR fluoroscopy; Interventional MR; Vascular disease

Indexed keywords

CATHETER ABLATION; CORONARY ARTERY; CORONARY STENT; DEVICE; ENDOVASCULAR SURGERY; FEMORAL ARTERY; HEART ATRIUM SEPTUM DEFECT; HEART CATHETERIZATION; HUMAN; INTERVENTIONAL RADIOLOGY; MAGNETIC RESONANCE ANGIOGRAPHY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PULMONARY ARTERY; PULMONARY VALVE; RENAL ARTERY; REVIEW;

EID: 26244464270     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20411     Document Type: Review
Times cited : (24)

References (83)
  • 1
    • 0033818533 scopus 로고    scopus 로고
    • MR-guided balloon angioplasty of stenosed aorta: In vivo evaluation using near-standard instruments and a passive tracking technique
    • Godart F, Beregi JP, Nicol L, et al. MR-guided balloon angioplasty of stenosed aorta: In vivo evaluation using near-standard instruments and a passive tracking technique. J Magn Reson Imaging 2000;12: 639-644.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 639-644
    • Godart, F.1    Beregi, J.P.2    Nicol, L.3
  • 2
    • 0037293344 scopus 로고    scopus 로고
    • Endovascular stents in pulmonary valve and artery in swine: Feasibility study of MR imaging-guided deployment and postinterventional assessment
    • Kuehne T, Saeed M, Higgins CB, et al. Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment. Radiology 2003;226:475-481.
    • (2003) Radiology , vol.226 , pp. 475-481
    • Kuehne, T.1    Saeed, M.2    Higgins, C.B.3
  • 3
    • 0033819206 scopus 로고    scopus 로고
    • Real-time MR fluoroscopy for MR-guided iliac artery stent placement
    • Buecker A, Neuerburg JM. Adam GB, et al. Real-time MR fluoroscopy for MR-guided iliac artery stent placement. J Magn Reson Imaging 2000;12:616-622.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 616-622
    • Buecker, A.1    Neuerburg, J.M.2    Adam, G.B.3
  • 4
    • 0035061283 scopus 로고    scopus 로고
    • MR imaging-gulded stent placement in iliac arterial stenoses: A feasibility study
    • Manke C, Nitz WR, Djavidani B, et al. MR imaging-gulded stent placement in iliac arterial stenoses: a feasibility study. Radiology 2001;219:527-534.
    • (2001) Radiology , vol.219 , pp. 527-534
    • Manke, C.1    Nitz, W.R.2    Djavidani, B.3
  • 5
    • 0034020669 scopus 로고    scopus 로고
    • MR-guided angioplasty of renal artery stenosis in a pig model: A feasibility study
    • Omary RA, Frayne R, Unal O, et al. MR-guided angioplasty of renal artery stenosis in a pig model: a feasibility study. J Vasc Interv Radiol 2000;11:373-381.
    • (2000) J Vasc Interv Radiol , vol.11 , pp. 373-381
    • Omary, R.A.1    Frayne, R.2    Unal, O.3
  • 6
    • 0033818666 scopus 로고    scopus 로고
    • Toward MRI-guided coronary catheterization: Visualization of guiding catheters, guidewires, and anatomy in real time
    • Serfaty JM, Yang X, Aksit P, et al. Toward MRI-guided coronary catheterization: visualization of guiding catheters, guidewires, and anatomy in real time. J Magn Reson Imaging 2000;12:590-594.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 590-594
    • Serfaty, J.M.1    Yang, X.2    Aksit, P.3
  • 7
    • 0037133176 scopus 로고    scopus 로고
    • MR-guided coronary stent placement in a pig model
    • Spuentrup E, Ruebben A, Schaeffter T, et al. MR-guided coronary stent placement in a pig model. Circulation 2002;105:874-879.
    • (2002) Circulation , vol.105 , pp. 874-879
    • Spuentrup, E.1    Ruebben, A.2    Schaeffter, T.3
  • 8
    • 0036129676 scopus 로고    scopus 로고
    • Real-time MR guidance for placement of a self-made fully MR-compatible atrial septal occluder: In vitro test
    • Buecker A, Spuentrup E, Grabitz R, et al. Real-time MR guidance for placement of a self-made fully MR-compatible atrial septal occluder: in vitro test. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 2002;174:283-285.
    • (2002) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.174 , pp. 283-285
    • Buecker, A.1    Spuentrup, E.2    Grabitz, R.3
  • 9
    • 0037422587 scopus 로고    scopus 로고
    • Magnetic resonance image-guided transcatheter closure of atrial septal defects
    • Rickers C, Jerosch-Herold M, Hu X, et al. Magnetic resonance image-guided transcatheter closure of atrial septal defects. Circulation 2003;107:132-138.
    • (2003) Circulation , vol.107 , pp. 132-138
    • Rickers, C.1    Jerosch-Herold, M.2    Hu, X.3
  • 10
    • 0034622655 scopus 로고    scopus 로고
    • Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging
    • Lardo AC, McVeigh ER, Jumrussirikul P, et al. Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging. Circulation 2000; 102:698-670.
    • (2000) Circulation , vol.102 , pp. 698-1670
    • Lardo, A.C.1    McVeigh, E.R.2    Jumrussirikul, P.3
  • 11
    • 0037133679 scopus 로고    scopus 로고
    • Catheter-based endomyocardial injection with real-time magnetic resonance imaging
    • Lederman RJ, Guttman MA, Peters DC, et al. Catheter-based endomyocardial injection with real-time magnetic resonance imaging. Circulation 2002;105:1282-1284.
    • (2002) Circulation , vol.105 , pp. 1282-1284
    • Lederman, R.J.1    Guttman, M.A.2    Peters, D.C.3
  • 12
    • 0029005879 scopus 로고
    • Superconducting open-configuration MR imaging system for image-guided therapy
    • Schenck JF, Jolesz FA, Roemer PB. et al. Superconducting open-configuration MR imaging system for image-guided therapy. Radiology 1995;195:805-814.
    • (1995) Radiology , vol.195 , pp. 805-814
    • Schenck, J.F.1    Jolesz, F.A.2    Roemer, P.B.3
  • 13
    • 18344404209 scopus 로고    scopus 로고
    • Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery
    • Tronnier VM, Wirtz CR, Knauth M, et al. Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery. Neurosurgery 1997;40:891-900.
    • (1997) Neurosurgery , vol.40 , pp. 891-900
    • Tronnier, V.M.1    Wirtz, C.R.2    Knauth, M.3
  • 14
    • 0031910940 scopus 로고    scopus 로고
    • MR-guided balloon angioplasty: In-vitro demonstration of the potential of MRI for guiding, monitoring and evaluating endovascular interventions
    • Bakker CJ. MR-guided balloon angioplasty: in-vitro demonstration of the potential of MRI for guiding, monitoring and evaluating endovascular interventions. J Magn Reson Imaging 1998;8:245-250.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 245-250
    • Bakker, C.J.1
  • 15
    • 0036105905 scopus 로고    scopus 로고
    • MR safety and the American College of Radiology white paper
    • Shellock FG, Crues JV. MR safety and the American College of Radiology white paper. AJR Am J Roentgenol 2002;178:1349-1352.
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 1349-1352
    • Shellock, F.G.1    Crues, J.V.2
  • 16
    • 0036829965 scopus 로고    scopus 로고
    • Magnetic resonance safety band update 2002: Implants and devices
    • Shellock FG. Magnetic resonance safety band update 2002: implants and devices. J Magn Reson Imaging 2002;16:485-496.
    • (2002) J Magn Reson Imaging , vol.16 , pp. 485-496
    • Shellock, F.G.1
  • 17
    • 0028364655 scopus 로고
    • Absence of movement of coronary stents after placement in a magnetic resonance imaging field
    • Scott NA, Pettigrew RI. Absence of movement of coronary stents after placement in a magnetic resonance imaging field. Am J Cardiol 1994;73:900-901.
    • (1994) Am J Cardiol , vol.73 , pp. 900-901
    • Scott, N.A.1    Pettigrew, R.I.2
  • 18
    • 0023832613 scopus 로고
    • MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents, and coils
    • Teitelbaum GP, Bradley WG, Klein BD. MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents, and coils. Radiology 1988;166:657-664.
    • (1988) Radiology , vol.166 , pp. 657-664
    • Teitelbaum, G.P.1    Bradley, W.G.2    Klein, B.D.3
  • 19
    • 0033777609 scopus 로고    scopus 로고
    • Selective contrast-enhanced MR angiography
    • Bos C, Smits HF, Bakker CJ, et al. Selective contrast-enhanced MR angiography. Magn Reson Med 2000;44:575-582.
    • (2000) Magn Reson Med , vol.44 , pp. 575-582
    • Bos, C.1    Smits, H.F.2    Bakker, C.J.3
  • 20
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 22
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47:1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 23
    • 0027207367 scopus 로고
    • Real-time acquisition, display, and interactive graphic control of NMR cardiac profiles and images
    • Hardy CJ, Darrow RD, Nieters EJ, et al. Real-time acquisition, display, and interactive graphic control of NMR cardiac profiles and images. Magn Reson Med 1993;29:667-673.
    • (1993) Magn Reson Med , vol.29 , pp. 667-673
    • Hardy, C.J.1    Darrow, R.D.2    Nieters, E.J.3
  • 24
    • 0033901334 scopus 로고    scopus 로고
    • Transcatheter implantation of a bovine valve in pulmonary position: A lamb study
    • Bonhoeffer P, Boudjemline Y, Saliba Z, et al. Transcatheter implantation of a bovine valve in pulmonary position: a lamb study. Circulation 2000;102:813-816.
    • (2000) Circulation , vol.102 , pp. 813-816
    • Bonhoeffer, P.1    Boudjemline, Y.2    Saliba, Z.3
  • 25
    • 0042092035 scopus 로고    scopus 로고
    • Steady-state imaging for visualization of endovascular interventions
    • Martin AJ, Weber OM, Saeed M, et al. Steady-state imaging for visualization of endovascular interventions. Magn Reson Med 2003;50:434-438.
    • (2003) Magn Reson Med , vol.50 , pp. 434-438
    • Martin, A.J.1    Weber, O.M.2    Saeed, M.3
  • 26
    • 0029907019 scopus 로고    scopus 로고
    • Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions
    • Bakker CJ, Hoogeveen RM, Weber J, et al. Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions. Magn Reson Med 1996;36:816-820.
    • (1996) Magn Reson Med , vol.36 , pp. 816-820
    • Bakker, C.J.1    Hoogeveen, R.M.2    Weber, J.3
  • 27
    • 0028899205 scopus 로고
    • Intravascular MR tracking catheter: Preliminary experimental evaluation
    • Leung DA, Debatin JF, Wildermuth S, et al. Intravascular MR tracking catheter: preliminary experimental evaluation. AJR Am J Roentgenol 1995;164:1265-1270.
    • (1995) AJR Am J Roentgenol , vol.164 , pp. 1265-1270
    • Leung, D.A.1    Debatin, J.F.2    Wildermuth, S.3
  • 28
    • 0033800058 scopus 로고    scopus 로고
    • Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters
    • Omary R, Unal O, Koscielski DS, et al. Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters. J Vasc Intervent Radiol 2000;11:1079-1085.
    • (2000) J Vasc Intervent Radiol , vol.11 , pp. 1079-1085
    • Omary, R.1    Unal, O.2    Koscielski, D.S.3
  • 29
    • 0031848729 scopus 로고    scopus 로고
    • A rapid 2D time-resolved variable-rate k-space sampling MR technique for passive catheter tracking during endovascular procedures
    • Unal O, Korosec FR, Frayne R, et al. A rapid 2D time-resolved variable-rate k-space sampling MR technique for passive catheter tracking during endovascular procedures Magn Reson Med 1998; 40:356-62.
    • (1998) Magn Reson Med , vol.40 , pp. 356-362
    • Unal, O.1    Korosec, F.R.2    Frayne, R.3
  • 30
    • 0027399141 scopus 로고
    • Real-time position monitoring of invasive devices using magnetic resonance
    • Dumoulin CL, Souza SP, Darrow RD. Real-time position monitoring of invasive devices using magnetic resonance. Magn Reson Med 1993;29:411-415.
    • (1993) Magn Reson Med , vol.29 , pp. 411-415
    • Dumoulin, C.L.1    Souza, S.P.2    Darrow, R.D.3
  • 32
    • 0031412997 scopus 로고    scopus 로고
    • MR angiography with an ultrasmall superparamagnetic iron oxide blood pool agent
    • Anzai Y, Prince MR, Chenevert TL, et al. MR angiography with an ultrasmall superparamagnetic iron oxide blood pool agent. J Magn Reson Imaging 1997;7:209-214.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 209-214
    • Anzai, Y.1    Prince, M.R.2    Chenevert, T.L.3
  • 33
    • 0031836465 scopus 로고    scopus 로고
    • MS-325: Albumin-targeted contrast agent for MR angiography
    • Lauffer RB, Parmelee DJ, Dunham SU, et al. MS-325: albumin-targeted contrast agent for MR angiography. Radiology 1998;207: 529-538.
    • (1998) Radiology , vol.207 , pp. 529-538
    • Lauffer, R.B.1    Parmelee, D.J.2    Dunham, S.U.3
  • 34
    • 2442709106 scopus 로고    scopus 로고
    • Transendocardial delivery of extracellular myocardial markers by using combination X-ray/MR fluoroscopic guidance: Feasibility study in dogs
    • Saeed M, Lee R, Martin A, et al. Transendocardial delivery of extracellular myocardial markers by using combination X-ray/MR fluoroscopic guidance: feasibility study in dogs. Radiology 2004;231: 689-696.
    • (2004) Radiology , vol.231 , pp. 689-696
    • Saeed, M.1    Lee, R.2    Martin, A.3
  • 35
    • 0027159714 scopus 로고
    • Susceptibility artifacts in 2DFT spin-echo and gradient-echo imaging: The cylinder model revisited
    • Bakker CJ, Bhagwandien R, Moerland MA, et al. Susceptibility artifacts in 2DFT spin-echo and gradient-echo imaging: the cylinder model revisited. Magn Reson Imaging 1993;11:539-548.
    • (1993) Magn Reson Imaging , vol.11 , pp. 539-548
    • Bakker, C.J.1    Bhagwandien, R.2    Moerland, M.A.3
  • 36
    • 0030854650 scopus 로고    scopus 로고
    • Catheter visualization using locally induced, actively controlled field inhomogeneities
    • Glowinski A, Adam G, Bucker A, et al. Catheter visualization using locally induced, actively controlled field inhomogeneities. Magn Reson Med 1997;38:253-258.
    • (1997) Magn Reson Med , vol.38 , pp. 253-258
    • Glowinski, A.1    Adam, G.2    Bucker, A.3
  • 38
    • 0035163917 scopus 로고    scopus 로고
    • Development of an MR-safe tracking catheter with a laser-driven tip coil
    • Konings MK, Bartels LW, van Swol CF, et al. Development of an MR-safe tracking catheter with a laser-driven tip coil. J Magn Reson Imaging 2001;13:131-135.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 131-135
    • Konings, M.K.1    Bartels, L.W.2    Van Swol, C.F.3
  • 39
    • 0029781333 scopus 로고    scopus 로고
    • Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetization
    • Burl M, Coutts GA, Young IR. Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetization. Magn Reson Med 1996;36:491-493.
    • (1996) Magn Reson Med , vol.36 , pp. 491-493
    • Burl, M.1    Coutts, G.A.2    Young, I.R.3
  • 40
    • 0007874282 scopus 로고    scopus 로고
    • Catheter localization using a resonant fiducial marker during interactive MR fluoroscopy
    • Philadelphia
    • Weiss S, Schaeffter T, Luedeke KM, et al. Catheter localization using a resonant fiducial marker during interactive MR fluoroscopy. In: Proceedings of the 7th Annual Meeting of ISMRM, Philadelphia, 1999. p 1954.
    • (1999) Proceedings of the 7th Annual Meeting of ISMRM , pp. 1954
    • Weiss, S.1    Schaeffter, T.2    Luedeke, K.M.3
  • 41
    • 0037544840 scopus 로고    scopus 로고
    • MR-controlled fast optical switching of a resonant circuit mounted on the tip of a clinical catheter
    • Glasgow, Scotland
    • Weiss S, Eggers H, Schaeffter T. MR-controlled fast optical switching of a resonant circuit mounted on the tip of a clinical catheter. In: Proceedings of the 9th Annual Meeting of ISMRM, Glasgow, Scotland, 2001. p 544.
    • (2001) Proceedings of the 9th Annual Meeting of ISMRM , pp. 544
    • Weiss, S.1    Eggers, H.2    Schaeffter, T.3
  • 42
    • 0033819207 scopus 로고    scopus 로고
    • An optical system for wireless detuning of parallel resonant circuits
    • Wong EY, Zhang Q, Duerk JL, et al. An optical system for wireless detuning of parallel resonant circuits. J Magn Reson Imaging 2000; 12:632-638.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 632-638
    • Wong, E.Y.1    Zhang, Q.2    Duerk, J.L.3
  • 44
    • 0031934082 scopus 로고    scopus 로고
    • Shifted rotated keyhole imaging and active tip-tracking for interventional procedure guidance
    • Wendt M, Busch M, Wetzler R, et al. Shifted rotated keyhole imaging and active tip-tracking for interventional procedure guidance. J Magn Reson Imaging 1998;8:258-261.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 258-261
    • Wendt, M.1    Busch, M.2    Wetzler, R.3
  • 45
    • 0031023708 scopus 로고    scopus 로고
    • Intravascular magnetic resonance imaging using a loopless catheter antenna
    • Ocali O, Atalar E. Intravascular magnetic resonance imaging using a loopless catheter antenna. Magn Reson Med 1997;37:112-118.
    • (1997) Magn Reson Med , vol.37 , pp. 112-118
    • Ocali, O.1    Atalar, E.2
  • 46
    • 0028822785 scopus 로고
    • Real-time biplanar needle tracking for interventional MR imaging procedures
    • Leung DA, Debatin JF, Wildermuth S, et al. Real-time biplanar needle tracking for interventional MR imaging procedures. Radiology 1995;197:485-488.
    • (1995) Radiology , vol.197 , pp. 485-488
    • Leung, D.A.1    Debatin, J.F.2    Wildermuth, S.3
  • 48
    • 0030003113 scopus 로고    scopus 로고
    • Towards active guidewire visualization in interventional magnetic resonance imaging
    • McKinnon GC, Debatin JF, Leung DA, et al. Towards active guidewire visualization in interventional magnetic resonance imaging. MAGMA 1996;4:13-18.
    • (1996) MAGMA , vol.4 , pp. 13-18
    • McKinnon, G.C.1    Debatin, J.F.2    Leung, D.A.3
  • 49
    • 0007925850 scopus 로고    scopus 로고
    • Comparison of two approaches to transmit/receive RF systems for intravascular use
    • Vancouver, Canada
    • Burl M, Young IR, Herlihy AH, et al. Comparison of two approaches to transmit/receive RF systems for intravascular use. In: Proceedings of the 5th Annual Meeting of ISMRM, Vancouver, Canada, 1997. p 1519.
    • (1997) Proceedings of the 5th Annual Meeting of ISMRM , pp. 1519
    • Burl, M.1    Young, I.R.2    Herlihy, A.H.3
  • 50
  • 51
    • 0031886921 scopus 로고    scopus 로고
    • Active MR visualization of a vascular guidewire in vivo
    • Ladd ME, Zimmermann GC, Quick HH, et al. Active MR visualization of a vascular guidewire in vivo. J Magn Reson Imaging 1998; 8;220-225.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 220-225
    • Ladd, M.E.1    Zimmermann, G.C.2    Quick, H.H.3
  • 52
    • 0033061925 scopus 로고    scopus 로고
    • Twisted-pair RF coil suitable for locating the track of a catheter
    • Burl M, Coutts GA, Herlihy DJ, et al. Twisted-pair RF coil suitable for locating the track of a catheter. Magn Reson Med 1999;41:636-638.
    • (1999) Magn Reson Med , vol.41 , pp. 636-638
    • Burl, M.1    Coutts, G.A.2    Herlihy, D.J.3
  • 53
    • 0142053953 scopus 로고    scopus 로고
    • Magnetic resonance-guided cardiac catheterization in a swine model of atrial septal defect
    • Schalla S, Saeed M, Higgins CB, et al. Magnetic resonance-guided cardiac catheterization in a swine model of atrial septal defect Circulation 2003;108:1865-1870.
    • (2003) Circulation , vol.108 , pp. 1865-1870
    • Schalla, S.1    Saeed, M.2    Higgins, C.B.3
  • 54
    • 0034330763 scopus 로고    scopus 로고
    • Determination of optimal injection parameters for intraarterial gadolinium-enhanced MR angiography
    • Frayne R, Omary RA, Unal O, et al. Determination of optimal injection parameters for intraarterial gadolinium-enhanced MR angiography. J Vasc Interv Radiol 2000;11:1277-1284.
    • (2000) J Vasc Interv Radiol , vol.11 , pp. 1277-1284
    • Frayne, R.1    Omary, R.A.2    Unal, O.3
  • 55
    • 22844448459 scopus 로고    scopus 로고
    • MRI in guiding and assessing intramyocardial therapy
    • Saeed M, Saloner D, Weber O, et al. MRI in guiding and assessing intramyocardial therapy. Eur Radiol 2005;15:851-863.
    • (2005) Eur Radiol , vol.15 , pp. 851-863
    • Saeed, M.1    Saloner, D.2    Weber, O.3
  • 56
    • 26244449396 scopus 로고    scopus 로고
    • Optimization of intra-arterial contrast agent delivery for MR angiography
    • Abstract #348
    • Martin A, Saeed M, Weber O, et al. Optimization of intra-arterial contrast agent delivery for MR angiography. J Cardiovasc Magn Reson 2003;5:Abstract #348.
    • (2003) J Cardiovasc Magn Reson , vol.5
    • Martin, A.1    Saeed, M.2    Weber, O.3
  • 57
    • 0036234013 scopus 로고    scopus 로고
    • Influence of blood pool contrast media on MR imaging and flow measurements in the presence of pulmonary artery stents in swine
    • Kuehne T, Saeed M, Moore P, et al. Influence of blood pool contrast media on MR imaging and flow measurements in the presence of pulmonary artery stents in swine. Radiology 2002;203:439-445.
    • (2002) Radiology , vol.203 , pp. 439-445
    • Kuehne, T.1    Saeed, M.2    Moore, P.3
  • 58
    • 0029623014 scopus 로고
    • Gene therapy for vascular diseases
    • Nabel EG. Gene therapy for vascular diseases. Atherosclerosis 1995;118:51-56.
    • (1995) Atherosclerosis , vol.118 , pp. 51-56
    • Nabel, E.G.1
  • 60
    • 0037648864 scopus 로고    scopus 로고
    • In vivo magnetic resonance imaging of mesenchymal stem cells in myocardial infarction
    • Kraitchman DL, Heldman AW, Atalar E, et al. In vivo magnetic resonance imaging of mesenchymal stem cells in myocardial infarction. Circulation 2003;107:2290-2293.
    • (2003) Circulation , vol.107 , pp. 2290-2293
    • Kraitchman, D.L.1    Heldman, A.W.2    Atalar, E.3
  • 61
    • 0035797863 scopus 로고    scopus 로고
    • Magnetic resonance permits in-vivo monitoring of catheter based vascular gene delivery
    • Yang X, Atalar E, Li D, et al. Magnetic resonance permits in-vivo monitoring of catheter based vascular gene delivery. Circulation 2001;104:1588-1590.
    • (2001) Circulation , vol.104 , pp. 1588-1590
    • Yang, X.1    Atalar, E.2    Li, D.3
  • 62
    • 12244308510 scopus 로고    scopus 로고
    • Transcatheter arterial chemoembolization (TACE) in treatment of hepatocellular carcinoma
    • Barone M, Ettorre GC, Ladisa R, et al. Transcatheter arterial chemoembolization (TACE) in treatment of hepatocellular carcinoma. Hepatogastroenterology 2003;50:183-187.
    • (2003) Hepatogastroenterology , vol.50 , pp. 183-187
    • Barone, M.1    Ettorre, G.C.2    Ladisa, R.3
  • 63
    • 0037345953 scopus 로고    scopus 로고
    • The safety, efficacy, and pharmacoeconomics of low-dose alteplase compared with urokinase for catheter-directed thrombolysis of arterial and venous occlusions
    • Sugimoto K, Hofmann LV, Razavi MK, et al. The safety, efficacy, and pharmacoeconomics of low-dose alteplase compared with urokinase for catheter-directed thrombolysis of arterial and venous occlusions. J Vasc Surg 2003;37:512-517.
    • (2003) J Vasc Surg , vol.37 , pp. 512-517
    • Sugimoto, K.1    Hofmann, L.V.2    Razavi, M.K.3
  • 64
    • 10744224950 scopus 로고    scopus 로고
    • Cardiac catheterisation guided by MRI in children and adults with congenital heart disease
    • Razavi R, Hill DL, Keevil SF, et al. Cardiac catheterisation guided by MRI in children and adults with congenital heart disease. Lancet 2003;362:1877-1882.
    • (2003) Lancet , vol.362 , pp. 1877-1882
    • Razavi, R.1    Hill, D.L.2    Keevil, S.F.3
  • 65
    • 0022615422 scopus 로고
    • Radiation doses and somatic risk to patients during cardiac radiological procedures
    • Faulkner K, Love HG, Sweeney JK, et al. Radiation doses and somatic risk to patients during cardiac radiological procedures. B J Radiol 1986;59:359-363.
    • (1986) B J Radiol , vol.59 , pp. 359-363
    • Faulkner, K.1    Love, H.G.2    Sweeney, J.K.3
  • 66
    • 14044260645 scopus 로고    scopus 로고
    • Balloon sizing and transcatheter closure of acute atrial septal defects guided by magnetic resonance fluoroscopy: Assessment and validation in a large animal model
    • Schalla S, Saeed M, Higgins CB, et al. Balloon sizing and transcatheter closure of acute atrial septal defects guided by magnetic resonance fluoroscopy: Assessment and validation in a large animal model. J Magn Reson Imaging 2005;21:204-211.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 204-211
    • Schalla, S.1    Saeed, M.2    Higgins, C.B.3
  • 67
    • 10744224950 scopus 로고    scopus 로고
    • Cardiac catheterisation guided by MRI in children and adults with congenital heart disease
    • Razavi R, Hill DL, Keevil SF, et al. Cardiac catheterisation guided by MRI in children and adults with congenital heart disease. Lancet 2003;362:1877-1882.
    • (2003) Lancet , vol.362 , pp. 1877-1882
    • Razavi, R.1    Hill, D.L.2    Keevil, S.F.3
  • 68
    • 0033639269 scopus 로고    scopus 로고
    • Editorial: Transcatheter closure of atrial septal defects (review)
    • Austin EH. Editorial: transcatheter closure of atrial septal defects (review). J Thorac Cardiovasc Surg 2000;120:1032-1033.
    • (2000) J Thorac Cardiovasc Surg , vol.120 , pp. 1032-1033
    • Austin, E.H.1
  • 69
    • 0032719491 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defects
    • Syamasundar RP, Sideris EB. Transcatheter closure of atrial septal defects. Heart 1999;82:644.
    • (1999) Heart , vol.82 , pp. 644
    • Syamasundar, R.P.1    Sideris, E.B.2
  • 70
    • 0035822607 scopus 로고    scopus 로고
    • Development and testing of the Helex septal occluder, a new expanded polytetrafluoroethylene ASD occlusion system
    • Zahn EM, Wilson N, Outright W, et al. Development and testing of the Helex septal occluder, a new expanded polytetrafluoroethylene ASD occlusion system. Circulation 2001;104:711-716.
    • (2001) Circulation , vol.104 , pp. 711-716
    • Zahn, E.M.1    Wilson, N.2    Outright, W.3
  • 71
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • Brenner DJ, Elliston CD, Hall EJ, et al. Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 2001;176:289-296.
    • (2001) AJR Am J Roentgenol , vol.176 , pp. 289-296
    • Brenner, D.J.1    Elliston, C.D.2    Hall, E.J.3
  • 72
    • 0034100816 scopus 로고    scopus 로고
    • Optimization of a fluoroscope to reduce radiation exposure in pediatric imaging
    • Brown PH, Thomas RD, Silberberg PJ, et al. Optimization of a fluoroscope to reduce radiation exposure in pediatric imaging. Pediatr Radiol 2000;30:229-235.
    • (2000) Pediatr Radiol , vol.30 , pp. 229-235
    • Brown, P.H.1    Thomas, R.D.2    Silberberg, P.J.3
  • 73
    • 0034000513 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defects without fluoroscopy: Feasibility of a new method
    • Ewert P, Berger F, Daehnert I, et al. Transcatheter closure of atrial septal defects without fluoroscopy: feasibility of a new method. Circulation 2000;101:847-849.
    • (2000) Circulation , vol.101 , pp. 847-849
    • Ewert, P.1    Berger, F.2    Daehnert, I.3
  • 74
    • 0030586964 scopus 로고    scopus 로고
    • Magnetic deflection forces from atrial septal defect and patent ductus arteriosus-occluding devices, stents, and coils used in pediatric-aged patients
    • Strouse PJ, Beekman RH. Magnetic deflection forces from atrial septal defect and patent ductus arteriosus-occluding devices, stents, and coils used in pediatric-aged patients. Am J Cardiol 1996;78:490-491.
    • (1996) Am J Cardiol , vol.78 , pp. 490-491
    • Strouse, P.J.1    Beekman, R.H.2
  • 75
    • 0030995970 scopus 로고    scopus 로고
    • Transvenous closure of secundum atrial septal defects: Preliminary results with a new self-expanding nitinol prosthesis in a swine model
    • Sharafuddin MJ, Gu X, Titus JL, et al. Transvenous closure of secundum atrial septal defects: preliminary results with a new self-expanding nitinol prosthesis in a swine model. Circulation 1997;95:2162-2168.
    • (1997) Circulation , vol.95 , pp. 2162-2168
    • Sharafuddin, M.J.1    Gu, X.2    Titus, J.L.3
  • 76
    • 0027991120 scopus 로고
    • Evaluation of cardiac function with magnetic resonance imaging
    • Pattynama PMT, de Roos A, van der Wall E, et al. Evaluation of cardiac function with magnetic resonance imaging. Am Heart J 1994;128:595-607.
    • (1994) Am Heart J , vol.128 , pp. 595-607
    • Pattynama, P.M.T.1    De Roos, A.2    Van Der Wall, E.3
  • 77
    • 0025744307 scopus 로고
    • Right and left lung perfusion: In vitro and in vivo validation with oblique-angle velocity-encoded cine MR imaging
    • Caputo GR, Kondo C, Masui T, et al. Right and left lung perfusion: in vitro and in vivo validation with oblique-angle velocity-encoded cine MR imaging. Radiology 1991;180:693-698.
    • (1991) Radiology , vol.180 , pp. 693-698
    • Caputo, G.R.1    Kondo, C.2    Masui, T.3
  • 78
    • 0028122164 scopus 로고
    • Quantification of collateral blood flow in coarctation of the aorta by velocity encoded cine magnetic resonance imaging
    • Steffens JC, Bourne MW, Sakuma H, et al. Quantification of collateral blood flow in coarctation of the aorta by velocity encoded cine magnetic resonance imaging. Circulation 1994;90: 937-943.
    • (1994) Circulation , vol.90 , pp. 937-943
    • Steffens, J.C.1    Bourne, M.W.2    Sakuma, H.3
  • 79
    • 0026718247 scopus 로고
    • Intravascular stent prosthesis for right ventricular outflow obstruction
    • Hosking MC, Benson LN, Nakanishi T, et al. Intravascular stent prosthesis for right ventricular outflow obstruction. J Am Coll Cardiol 1992;20:373-380.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 373-380
    • Hosking, M.C.1    Benson, L.N.2    Nakanishi, T.3
  • 81
    • 0027281614 scopus 로고
    • Implantation and intermediate-term follow-up of stents in congenital heart disease
    • O'Laughlin MP, Slack MC, Grifka RG, et al. Implantation and intermediate-term follow-up of stents in congenital heart disease. Circulation 1993;88:605-614.
    • (1993) Circulation , vol.88 , pp. 605-614
    • O'Laughlin, M.P.1    Slack, M.C.2    Grifka, R.G.3
  • 82
    • 0028793793 scopus 로고
    • Prolongation of RV-PA conduit life span by percutaneous stent implantation: Intermediate-term results
    • Powell AJ, Lock JE, Keane JF, et al. Prolongation of RV-PA conduit life span by percutaneous stent implantation: intermediate-term results. Circulation 1995;92:3282-3288.
    • (1995) Circulation , vol.92 , pp. 3282-3288
    • Powell, A.J.1    Lock, J.E.2    Keane, J.F.3
  • 83
    • 9644259162 scopus 로고    scopus 로고
    • Magnetic resonance imaging-guided transcatheter implantation of a prosthetic valve in aortic valve position: Feasibility study in swine
    • Kuehne T, Yilmaz S, Meinus C, et al. Magnetic resonance imaging-guided transcatheter implantation of a prosthetic valve in aortic valve position: Feasibility study in swine. J Am Coll Cardiol. 2004; 44:2247-2249.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 2247-2249
    • Kuehne, T.1    Yilmaz, S.2    Meinus, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.