메뉴 건너뛰기




Volumn 12, Issue 4, 2000, Pages 632-638

An optical system for wireless detuning of parallel resonant circuits

Author keywords

Active device tracking; Interventional MRI; Optical detuning; Patient safety

Indexed keywords

ARTICLE; DEVICE; EQUIPMENT; FIBER OPTICS; FOURIER ANALYSIS; LIGHT; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 0033819207     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/1522-2586(200010)12:4<632::AID-JMRI17>3.0.CO;2-J     Document Type: Article
Times cited : (68)

References (15)
  • 1
    • 0025674137 scopus 로고
    • Magnetic susceptibility effects and their application in the development of new ferromagnetic catheters for magnetic resonance imaging
    • (1990) Invest Radiol , vol.25 , pp. 1325-1332
    • Ratner, A.V.1    Young, S.W.2
  • 5
    • 0007874282 scopus 로고    scopus 로고
    • Catheter localization using a resonant fiducial marker during interactive MR fluoroscopy
    • Proceedings of the ISMRM 7th Scientific Meeting (abstract)
    • (1999) , vol.1 , pp. 1954
    • Weiss, S.1    Schaeffter, T.2    Luedeke, K.M.3
  • 6
    • 0002506995 scopus 로고    scopus 로고
    • Active visualization - MR tracking
    • Debatin JF. Adam G. editors. Interventional magnetic resonance imaging. Heidelberg; Springer
    • (1998) , pp. 65-75
    • Dumoulin, C.L.1
  • 7
    • 0002638632 scopus 로고    scopus 로고
    • RF heating of actively visualized catheters and guidewires
    • Proceedings of the ISMRM 6th Scientific Meeting (abstract)
    • (1998) , pp. 473
    • Ladd, M.E.1    Quick, H.H.2    Boesiger, P.3
  • 8
    • 0001885133 scopus 로고    scopus 로고
    • Heating effects of magnetic resonance imaging on pacemaker leads: Effect of lead types and positioning
    • Proceedings of the ISMRM 7th Scientific Meeting (abstract)
    • (1999) , vol.1 , pp. 103
    • Luechinger, R.1    Duru, F.2    Scheldegger, M.B.3
  • 10
    • 0007921971 scopus 로고    scopus 로고
    • Safe coaxial cables. Proceedings of the ISMRM 7th Scientific Meeting 1999 (abstract)
    • , vol.3 , pp. 1005
    • Atalar, E.1
  • 11
    • 0002686802 scopus 로고    scopus 로고
    • A 0.7 mm triaxial cable for significantly reducing RF heating in interventional MR
    • Proceedings of the ISMRM 7th Scientific Meeting 2099 (abstract)
    • , vol.1 , pp. 104
    • Ladd, M.E.1    Quick, H.H.2
  • 12
    • 0001306892 scopus 로고    scopus 로고
    • A novel inductively coupled RF coil system and automatic image segmentation for active MR invasive device tip tracking
    • Proceedings of the ISMRM 7th Scientific Meeting (abstract)
    • (1999) , vol.1 , pp. 583
    • Zhang, Q.1    Wendt, M.2    Zheng, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.