메뉴 건너뛰기




Volumn 26, Issue 1, 2005, Pages 28-35

Dynamic range requirements for MRI

Author keywords

Analog to digital; Dynamic range; High resolution; k space sampling; MRI; Quantization noise; Signal to noise ratio (SNR); Thermal noise; Variable gain

Indexed keywords


EID: 25444522321     PISSN: 10437347     EISSN: None     Source Type: Journal    
DOI: 10.1002/cmr.b.20042     Document Type: Article
Times cited : (34)

References (10)
  • 2
    • 0023492118 scopus 로고
    • Relations between the statistics of natural images and the response properties of cortical cells
    • Field DJ. 1987. Relations between the statistics of natural images and the response properties of cortical cells. J Opt Soc Am A 4:2379-2394.
    • (1987) J Opt Soc Am A , vol.4 , pp. 2379-2394
    • Field, D.J.1
  • 3
    • 0001187198 scopus 로고
    • Statistics of natural images: Scaling in the woods
    • Ruderman DL, Bialek W. 1994. Statistics of natural images: scaling in the woods. Phys Rev Lett 73:814-817.
    • (1994) Phys Rev Lett , vol.73 , pp. 814-817
    • Ruderman, D.L.1    Bialek, W.2
  • 4
    • 0024131143 scopus 로고
    • The information content of MR images
    • Fuderer M. 1988. The information content of MR images. IEEE Trans Med Imaging 7:368-380.
    • (1988) IEEE Trans Med Imaging , vol.7 , pp. 368-380
    • Fuderer, M.1
  • 5
    • 0036708139 scopus 로고    scopus 로고
    • k-Space interpretation of the Rose model: Noise limitation on the detectable resolution in MRI
    • Watts R, Wang Y. 2002. k-Space interpretation of the Rose model: noise limitation on the detectable resolution in MRI. Magn Reson Med 48:550-554.
    • (2002) Magn Reson Med , vol.48 , pp. 550-554
    • Watts, R.1    Wang, Y.2
  • 6
    • 0031989597 scopus 로고    scopus 로고
    • Improved resolution and signal-to-noise ratio in MRI via enhanced signal digitization
    • Elliott MA, Insko EK, Greenman RL, Leigh JS. 1998. Improved resolution and signal-to-noise ratio in MRI via enhanced signal digitization. J Magn Reson 130:300-304.
    • (1998) J Magn Reson , vol.130 , pp. 300-304
    • Elliott, M.A.1    Insko, E.K.2    Greenman, R.L.3    Leigh, J.S.4
  • 8
    • 46149134725 scopus 로고
    • Improvement of dynamic range in NMR by oversampling
    • Delsuc MA, Lallemand JY. 1986. Improvement of dynamic range in NMR by oversampling. J Magn Reson 69:504-507.
    • (1986) J Magn Reson , vol.69 , pp. 504-507
    • Delsuc, M.A.1    Lallemand, J.Y.2
  • 9
    • 0023913045 scopus 로고
    • Dynamic range compression in MRI by means of a nonlinear gradient pulse
    • Wedeen VJ, Chao YS, Ackerman JL. 1988. Dynamic range compression in MRI by means of a nonlinear gradient pulse. Magn Reson Med 6:287-295.
    • (1988) Magn Reson Med , vol.6 , pp. 287-295
    • Wedeen, V.J.1    Chao, Y.S.2    Ackerman, J.L.3
  • 10
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Henkelman RM. 1985. Measurement of signal intensities in the presence of noise in MR images. Med Phys 12:232-233.
    • (1985) Med Phys , vol.12 , pp. 232-233
    • Henkelman, R.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.