메뉴 건너뛰기




Volumn 130, Issue 2, 1998, Pages 300-304

Improved Resolution and Signal-to-Noise Ratio in MRI via Enhanced Signal Digitization

Author keywords

Digitization noise; Dynamic range; MRI

Indexed keywords

ARTICLE; ARTIFACT; COMPUTER SIMULATION; FOURIER ANALYSIS; IMAGE ENHANCEMENT; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING;

EID: 0031989597     PISSN: 10907807     EISSN: None     Source Type: Journal    
DOI: 10.1006/jmre.1997.1319     Document Type: Article
Times cited : (23)

References (8)
  • 1
    • 38249028655 scopus 로고
    • Dynamic range improvement in NMR imaging using phase scrambling
    • A. A. Maudsley, Dynamic range improvement in NMR imaging using phase scrambling, J. Magn. Reson. 76, 287-305 (1987).
    • (1987) J. Magn. Reson. , vol.76 , pp. 287-305
    • Maudsley, A.A.1
  • 2
    • 0023913045 scopus 로고
    • Dynamic range compression in MRI by means of nonlinear gradient pulse
    • V. J. Wedeen, Y. Chao, and J. L. Ackerman, Dynamic range compression in MRI by means of nonlinear gradient pulse, Magn. Reson. Med. 6, 287-295 (1988).
    • (1988) Magn. Reson. Med. , vol.6 , pp. 287-295
    • Wedeen, V.J.1    Chao, Y.2    Ackerman, J.L.3
  • 3
    • 0027066744 scopus 로고
    • Phase-scrambled RF excitation for 3D volume-selective multislice NMR imaging
    • C. H. Oh, S. K. Hilal, E. X. Wu, and Z. H. Cho, Phase-scrambled RF excitation for 3D volume-selective multislice NMR imaging, Magn. Reson. Med. 28, 290-299 (1992).
    • (1992) Magn. Reson. Med. , vol.28 , pp. 290-299
    • Oh, C.H.1    Hilal, S.K.2    Wu, E.X.3    Cho, Z.H.4
  • 4
    • 0028309265 scopus 로고
    • Optimized phase scrambling for RF phase encoding
    • G. Johnson, E. X. Wu, and S. K. Hilal, Optimized phase scrambling for RF phase encoding, J. Magn. Reson. B 103, 59-63 (1994).
    • (1994) J. Magn. Reson. B , vol.103 , pp. 59-63
    • Johnson, G.1    Wu, E.X.2    Hilal, S.K.3
  • 5
    • 0000366223 scopus 로고
    • Sensitivity in fourier imaging
    • A. A. Maudsley, Sensitivity in fourier imaging, J. Magn. Reson. 68, 363-366 (1986).
    • (1986) J. Magn. Reson. , vol.68 , pp. 363-366
    • Maudsley, A.A.1
  • 6
    • 0025445375 scopus 로고
    • Nonlinear amplitude compression in magnetic resonance imaging: Quantization noise reduction and data memory saving
    • K. Kose, K. Endoh, and T. Inouye, Nonlinear amplitude compression in magnetic resonance imaging: Quantization noise reduction and data memory saving, IEEE AES Magn. 6, 27-30 (1990).
    • (1990) IEEE AES Magn. , vol.6 , pp. 27-30
    • Kose, K.1    Endoh, K.2    Inouye, T.3
  • 8
    • 0002628408 scopus 로고
    • Digitisation and data processing in fourier transform NMR
    • J. C. Lindon and A. G. Ferrge, Digitisation and data processing in fourier transform NMR, Prog. NMR Spectrosc. 14, 27-66 (1980).
    • (1980) Prog. NMR Spectrosc. , vol.14 , pp. 27-66
    • Lindon, J.C.1    Ferrge, A.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.