메뉴 건너뛰기




Volumn 6, Issue 3, 2005, Pages 182-187

Dynamics and control of cavitation during high-intensity focused ultrasound application

Author keywords

[No Author keywords available]

Indexed keywords


EID: 25444515641     PISSN: 15297853     EISSN: None     Source Type: Journal    
DOI: 10.1121/1.1901744     Document Type: Article
Times cited : (39)

References (15)
  • 2
    • 0035673103 scopus 로고    scopus 로고
    • Measurements of bubble-enhanced heating from focused MHz-frequency ultrasound in a tissue mimicking material
    • R. G. Holt and R. A. Roy, "Measurements of bubble-enhanced heating from focused MHz-frequency ultrasound in a tissue mimicking material," Ultrasound Med. Biol. 27, 1399-1412 (2001).
    • (2001) Ultrasound Med. Biol. , vol.27 , pp. 1399-1412
    • Holt, R.G.1    Roy, R.A.2
  • 4
    • 0037458224 scopus 로고    scopus 로고
    • MRI-guided gas bubble enhanced ultrasound heating in in vivo rabbit thigh
    • S. Sokka, R. King, and K. Hynynen, "MRI-guided gas bubble enhanced ultrasound heating in in vivo rabbit thigh," Phys. Med. Biol. 48, 223-241 (2003).
    • (2003) Phys. Med. Biol. , vol.48 , pp. 223-241
    • Sokka, S.1    King, R.2    Hynynen, K.3
  • 5
    • 1042275628 scopus 로고    scopus 로고
    • Combination of thermal and cavitation effects to generate deep lesions with an endocavitary applicator using a plane transducer: Ex vivo studies
    • D. Melodelima, J.Y. Chapelon, Y. Theillere, and D. Cathignol, "Combination of thermal and cavitation effects to generate deep lesions with an endocavitary applicator using a plane transducer: Ex vivo studies," Ultrasound Med. Biol. 30, 103-111(2004).
    • (2004) Ultrasound Med. Biol. , vol.30 , pp. 103-111
    • Melodelima, D.1    Chapelon, J.Y.2    Theillere, Y.3    Cathignol, D.4
  • 6
    • 0030998856 scopus 로고    scopus 로고
    • High-intensity focused ultrasound ablation of the kidney in a large animal model
    • N. A. Watkin, S. B. Morris, I. H. Rivens, and G. R. TerHaar, "High-intensity focused ultrasound ablation of the kidney in a large animal model," J. Endourol 11, 191-196 (1997).
    • (1997) J. Endourol , vol.11 , pp. 191-196
    • Watkin, N.A.1    Morris, S.B.2    Rivens, I.H.3    Terhaar, G.R.4
  • 8
    • 0035057522 scopus 로고    scopus 로고
    • Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging
    • S. Vaezy, X. G. Shi, R. W. Martin, E. Chi, P. I. Nelson, M. R. Bailey, and L. A. Crum, "Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging," Ultrasound Med. Biol. 27, 33-42 (2001).
    • (2001) Ultrasound Med. Biol. , vol.27 , pp. 33-42
    • Vaezy, S.1    Shi, X.G.2    Martin, R.W.3    Chi, E.4    Nelson, P.I.5    Bailey, M.R.6    Crum, L.A.7
  • 9
    • 25444487581 scopus 로고    scopus 로고
    • note
    • In the paper, the first model number in the parentheses refers to equipment used in the VI experiment, and the second number refers to equipment used in the CC experiment. When only one model number appears, the same piece of equipment was used in both studies. The preamplifier used for the VI study was a Krohn-Hite 3955 filter set in by-pass mode, 40-dB total gain. In the CC study, two preamplifiers were used: an EG&G model 5185 (20 dB), and a Krohn-Hite 3950 set to 2-MHz high pass, with 40-dB total gain. In addition to the two preamplifiers, a 6-dB (50F-006) in-line attenuator was used in the CC study; thus, the total gain used in the CC study was 54 dB.
  • 11
    • 1042273342 scopus 로고    scopus 로고
    • Mechanisms of lesion formation in high intensity focused ultrasound
    • W.-S. Chen, C. Lafon, T. J. Matula, S. Vaezy, and L. A. Crum, "Mechanisms of lesion formation in high intensity focused ultrasound," ARLO 4, 41-46 (2003).
    • (2003) ARLO , vol.4 , pp. 41-46
    • Chen, W.-S.1    Lafon, C.2    Matula, T.J.3    Vaezy, S.4    Crum, L.A.5
  • 12
    • 0035730974 scopus 로고    scopus 로고
    • Development and characterization of an innovative synthetic tissue-mimicking material for high-intensity focused ultrasound (HIFU) exposures
    • C. Lafon, P. J. Kaczkowski, S. Vaezy, M. Noble, and O. A. Sapozhnikov, "Development and characterization of an innovative synthetic tissue-mimicking material for high-intensity focused ultrasound (HIFU) exposures," 2001 IEEE Ultrasonics Symposium, 1295-1298 (2001).
    • (2001) 2001 IEEE Ultrasonics Symposium , pp. 1295-1298
    • Lafon, C.1    Kaczkowski, P.J.2    Vaezy, S.3    Noble, M.4    Sapozhnikov, O.A.5
  • 13
    • 0029888837 scopus 로고    scopus 로고
    • The intensity dependence of the site of maximal energy deposition in focused ultrasound surgery
    • N. A. Watkin, G. R. terHaar, and I. Rivens, "The intensity dependence of the site of maximal energy deposition in focused ultrasound surgery," Ultrasound Med. Biol. 22, 483-491 (1996).
    • (1996) Ultrasound Med. Biol. , vol.22 , pp. 483-491
    • Watkin, N.A.1    Terhaar, G.R.2    Rivens, I.3
  • 15
    • 11144352197 scopus 로고    scopus 로고
    • Bubble dynamics and size distributions during focused ultrasound insonation
    • X. Yang, R. A. Roy, and R. G. Holt, "Bubble dynamics and size distributions during focused ultrasound insonation," J. Acoust. Soc. Am. 116, 3423-3431 (2004).
    • (2004) J. Acoust. Soc. Am. , vol.116 , pp. 3423-3431
    • Yang, X.1    Roy, R.A.2    Holt, R.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.