메뉴 건너뛰기




Volumn 11, Issue 3, 1997, Pages 191-196

High-intensity focused ultrasound ablation of the kidney in a large animal model

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; BURN; KIDNEY TUMOR; NONHUMAN; PRIORITY JOURNAL; RABBIT; RAT; THERMAL INJURY; TRANSDUCER; ULTRASOUND THERAPY;

EID: 0030998856     PISSN: 08927790     EISSN: None     Source Type: Journal    
DOI: 10.1089/end.1997.11.191     Document Type: Article
Times cited : (86)

References (22)
  • 1
    • 0027217920 scopus 로고
    • Prostatic tissue destruction by high intensity focused ultrasound: Experimentation on the canine prostate
    • Gelet A, Chapelon JY, Margonari J, et al: Prostatic tissue destruction by high intensity focused ultrasound: experimentation on the canine prostate. J Endourol 1993;7:249
    • (1993) J Endourol , vol.7 , pp. 249
    • Gelet, A.1    Chapelon, J.Y.2    Margonari, J.3
  • 2
    • 0028073506 scopus 로고
    • Tissue ablation in benign prostatic hyperplasia with high intensity focused ultrasound
    • Madersbacher S, Kratzik C, Susani M, Marberger M: Tissue ablation in benign prostatic hyperplasia with high intensity focused ultrasound. J Urol 1994;152:1956
    • (1994) J Urol , vol.152 , pp. 1956
    • Madersbacher, S.1    Kratzik, C.2    Susani, M.3    Marberger, M.4
  • 4
    • 0028212162 scopus 로고
    • Minimally invasive cancer surgery using focused ultrasound: A pre-clinical normal tissue study
    • Vaughan MG, ter Haar GR, Hill CR, Clarke RL, Hopewell JW: Minimally invasive cancer surgery using focused ultrasound: a pre-clinical normal tissue study. Br J Radiol 1994;67:267
    • (1994) Br J Radiol , vol.67 , pp. 267
    • Vaughan, M.G.1    Ter Haar, G.R.2    Hill, C.R.3    Clarke, R.L.4    Hopewell, J.W.5
  • 6
    • 0029888837 scopus 로고    scopus 로고
    • The intensity dependence of the site of maximal energy deposition in focused ultrasound surgery
    • Watkin NA, Rivens IH, ter Haar GR: The intensity dependence of the site of maximal energy deposition in focused ultrasound surgery. Ultrasound Med Biol 1996;22:483
    • (1996) Ultrasound Med Biol , vol.22 , pp. 483
    • Watkin, N.A.1    Rivens, I.H.2    Ter Haar, G.R.3
  • 8
    • 0026468620 scopus 로고
    • Effects on high-energy focused ultrasound on kidney tissue in the rat and the dog
    • Chapelon JY, Margonari J, Theillere Y, et al: Effects on high-energy focused ultrasound on kidney tissue in the rat and the dog. Eur Urol 1992;22:147
    • (1992) Eur Urol , vol.22 , pp. 147
    • Chapelon, J.Y.1    Margonari, J.2    Theillere, Y.3
  • 14
    • 0025329069 scopus 로고
    • Effects of physical parameters on high temperature ultrasound hyperthermia
    • Billard BE, Hynynen K, Roemer RB: Effects of physical parameters on high temperature ultrasound hyperthermia. Ultrasound Med Biol 1990;16:409
    • (1990) Ultrasound Med Biol , vol.16 , pp. 409
    • Billard, B.E.1    Hynynen, K.2    Roemer, R.B.3
  • 15
    • 0027527941 scopus 로고
    • Effect of blood perfusion on the ablation of liver parenchyma with high intensity focused ultrasound
    • Chen L, ter Haar GR, Hill CR, et al: Effect of blood perfusion on the ablation of liver parenchyma with high intensity focused ultrasound. Phys Med Biol 1993;38:1661
    • (1993) Phys Med Biol , vol.38 , pp. 1661
    • Chen, L.1    Ter Haar, G.R.2    Hill, C.R.3
  • 16
    • 0018600264 scopus 로고
    • Ultrasonic attenuation and propagation speed in mammalian tissues as a function of temperature
    • Bamber JC, Hill CR: Ultrasonic attenuation and propagation speed in mammalian tissues as a function of temperature. Ultrasound Med Biol 1979;5:149
    • (1979) Ultrasound Med Biol , vol.5 , pp. 149
    • Bamber, J.C.1    Hill, C.R.2
  • 17
    • 0014261697 scopus 로고
    • Trackless lesions in nervous tissue produced by high intensity focused ultrasound (high frequency mechanical waves)
    • Warwick R, Pond JB: Trackless lesions in nervous tissue produced by high intensity focused ultrasound (high frequency mechanical waves). J Anat 1968;102:387
    • (1968) J Anat , vol.102 , pp. 387
    • Warwick, R.1    Pond, J.B.2
  • 19
    • 0028914484 scopus 로고
    • Control of the necrosed tissue volume during noninvasive ultrasound surgery using a 16-element phased array
    • Fan X, Hynynen K: Control of the necrosed tissue volume during noninvasive ultrasound surgery using a 16-element phased array. Med Phys 1995;22:297
    • (1995) Med Phys , vol.22 , pp. 297
    • Fan, X.1    Hynynen, K.2
  • 20
    • 0027872370 scopus 로고
    • Sonographic and computed tomography characteristics of liver ablation lesions induced by high intensity focussed ultrasound
    • Yang R, Kopecky KK, Rescorla FJ, Galliani CA, Wu EX, Grosfield JL: Sonographic and computed tomography characteristics of liver ablation lesions induced by high intensity focussed ultrasound. Invest Radiol 1993;28:796
    • (1993) Invest Radiol , vol.28 , pp. 796
    • Yang, R.1    Kopecky, K.K.2    Rescorla, F.J.3    Galliani, C.A.4    Wu, E.X.5    Grosfield, J.L.6
  • 21
    • 0024407776 scopus 로고
    • High intensity focused ultrasound: A surgical technique for the treatment of discrete liver tumours
    • ter Haar GR, Sinnen D, Rivens IH: High intensity focused ultrasound: a surgical technique for the treatment of discrete liver tumours. Phys Med Biol 1989;34:1743
    • (1989) Phys Med Biol , vol.34 , pp. 1743
    • Ter Haar, G.R.1    Sinnen, D.2    Rivens, I.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.