Volumn 81, Issue 5, 2004, Pages 323-333

Clinical evaluation of the Topcon BV-1000 automated subjective refraction system

Author keywords

Accuracy; Automated subjective refraction; Autorefraction; Repeatability

Indexed keywords

AUTOMATION; DATA REDUCTION; REFRACTION; STATISTICAL METHODS;

EID: 2542561346     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.opx.0000134906.98403.c3     Document Type: Article
Times cited : (17)

References (16)
  • 1
    • 0033657349 scopus 로고    scopus 로고
    • A fully automated remote refraction system
    • Dyer AM, Kirk AH. A fully automated remote refraction system. J Telemed Telecare 2000;6(Suppl 2):S16-8.
    • (2000) J Telemed Telecare , vol.6 , Issue.SUPPL. 2
    • Dyer, A.M.1    Kirk, A.H.2
  • 2
    • 0018138981 scopus 로고
    • Computer-assisted eye examination. VI. Identification and correction of errors in the Refractor III system for subjective examination
    • Marg E, Anderson KW, Chung KO, Neroth CC. Computer-assisted eye examination. VI. Identification and correction of errors in the Refractor III system for subjective examination. Am J Optom Physiol Opt 1978;55:249-66.
    • (1978) J Optom Physiol Opt , vol.55 , pp. 249-266
    • Marg, E.1    Anderson, K.W.2    Chung, K.O.3    Neroth, C.C.4
  • 4
    • 2542541359 scopus 로고    scopus 로고
    • BV-1000 Automated Subjective Refraction System: Description and patient perceptions
    • Dave T. BV-1000 Automated Subjective Refraction System: description and patient perceptions. Optometry Today 2003;4:52-7.
    • (2003) Optometry Today , vol.4 , pp. 52-57
    • Dave, T.1
  • 5
    • 0031171614 scopus 로고    scopus 로고
    • Power vectors: An application of Fourier analysis to the description and statistical analysis of refractive error
    • Thibos LN, Wheeler W, Horner D. Power vectors: an application of Fourier analysis to the description and statistical analysis of refractive error. Optom Vis Sci 1997;74:367-75.
    • (1997) Optom Vis Sci , vol.74 , pp. 367-375
    • Thibos, L.N.1    Wheeler, W.2    Horner, D.3
  • 6
    • 0034916285 scopus 로고    scopus 로고
    • Repeatability of subjective refraction in myopic and keratoconic subjects: Results of vector analysis
    • Raasch TW, Schechtman KB, Davis LJ, Zadnik K. Repeatability of subjective refraction in myopic and keratoconic subjects: results of vector analysis. Ophthalmic Physiol Opt 2001;21:376-83.
    • (2001) Ophthalmic Physiol Opt , vol.21 , pp. 376-383
    • Raasch, T.W.1    Schechtman, K.B.2    Davis, L.J.3    Zadnik, K.4
  • 7
    • 0025732412 scopus 로고
    • Representation of dioptric power in Euclidean 3-space
    • Harris WF. Representation of dioptric power in Euclidean 3-space. Ophthalmic Physiol Opt 1991;11:130-6.
    • (1991) Ophthalmic Physiol Opt , vol.11 , pp. 130-136
    • Harris, W.F.1
  • 8
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 0035154816 scopus 로고    scopus 로고
    • Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in children
    • Chat SW, Edwards MH. Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in children. Ophthalmic Physiol Opt 2001; 21:87-100.
    • (2001) Ophthalmic Physiol Opt , vol.21 , pp. 87-100
    • Chat, S.W.1    Edwards, M.H.2
  • 11
    • 0030862133 scopus 로고    scopus 로고
    • Reproducibility and accuracy of measurements with a hand held autorefractor in children
    • Harvey EM, Miller JM, Wagner LK, Dobson V. Reproducibility and accuracy of measurements with a hand held autorefractor in children. Br J Ophthalmol 1997;81:941-8.
    • (1997) Br J Ophthalmol , vol.81 , pp. 941-948
    • Harvey, E.M.1    Miller, J.M.2    Wagner, L.K.3    Dobson, V.4
  • 12
  • 13
    • 0031171030 scopus 로고    scopus 로고
    • Repeatability and accuracy of automated refraction: A comparison of the Nikon NRK-8000, the Nidek AR-1000, and subjective refraction
    • Elliott M, Simpson T, Richter D, Fonn D. Repeatability and accuracy of automated refraction: a comparison of the Nikon NRK-8000, the Nidek AR-1000, and subjective refraction. Optom Vis Sci 1997; 74:434-8.
    • (1997) Optom Vis Sci , vol.74 , pp. 434-438
    • Elliott, M.1    Simpson, T.2    Richter, D.3    Fonn, D.4
  • 14
    • 0026652930 scopus 로고
    • The repeatability of measurement of the ocular components
    • Zadnik K, Mutti DO, Adams AJ. The repeatability of measurement of the ocular components. Invest Ophthalmol Vis Sci 1992;33: 2325-33.
    • (1992) Invest Ophthalmol Vis Sci , vol.33 , pp. 2325-2333
    • Zadnik, K.1    Mutti, D.O.2    Adams, A.J.3
  • 15
    • 0029115357 scopus 로고
    • Repeatability of subjective and objective refraction
    • Rosenfield M, Chiu NN. Repeatability of subjective and objective refraction. Optom Vis Sci 1995;72:577-9.
    • (1995) Optom Vis Sci , vol.72 , pp. 577-579
    • Rosenfield, M.1    Chiu, N.N.2
  • 16
    • 0032146250 scopus 로고    scopus 로고
    • The repeatability of automated and clinician refraction
    • Bullimore MA, Fusaro RE, Adams CW. The repeatability of automated and clinician refraction. Optom Vis Sci 1998;75:617-22.
    • (1998) Optom Vis Sci , vol.75 , pp. 617-622
    • Bullimore, M.A.1    Fusaro, R.E.2    Adams, C.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.