메뉴 건너뛰기




Volumn 69, Issue 12, 2003, Pages 907-918

Monitoring of intrathoracic volemia and cardiac output in critically ill children

Author keywords

Child; Heart, physiology; Hemodynamics

Indexed keywords

AIRWAY PRESSURE; ARTICLE; ARTIFICIAL VENTILATION; BLOOD VOLUME; CHILD; CLINICAL ARTICLE; COHORT ANALYSIS; CONTROLLED STUDY; CORRELATION ANALYSIS; CRITICAL ILLNESS; HEART INDEX; HEART OUTPUT; HEART PRELOAD; HEART STROKE VOLUME; HEMODYNAMIC MONITORING; HUMAN; INSPIRATORY CAPACITY; LUNG EXTRAVASCULAR FLUID; POSITIVE END EXPIRATORY PRESSURE; PROSPECTIVE STUDY; ADOLESCENT; INFANT; MONITORING; PRESCHOOL CHILD;

EID: 2542499939     PISSN: 03759393     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (21)

References (24)
  • 1
    • 0003050969 scopus 로고
    • Measurement of cardiac output in children: A United Kingdom perspective
    • Murdoch I. Measurement of cardiac output in children: a United Kingdom perspective. Clin Intensive Care 1994;4 Suppl 5:29-35.
    • (1994) Clin Intensive Care , vol.4 , Issue.SUPPL. 5 , pp. 29-35
    • Murdoch, I.1
  • 2
    • 0002807625 scopus 로고
    • Measurement of cardiac output in children
    • Fanconi S, Burger R. Measurement of cardiac output in children. Intensive Care World 1992;9:8-12.
    • (1992) Intensive Care World , vol.9 , pp. 8-12
    • Fanconi, S.1    Burger, R.2
  • 6
    • 0030475788 scopus 로고    scopus 로고
    • Central venous pressure, pulmonary artery occlusion pressure, intrathoracic blood volume, and right ventricular end diastolic volume as indicators of cardiac preload
    • Lichtwarck-Aschoff M, Beale R, Pfeiffer UJ. Central venous pressure, pulmonary artery occlusion pressure, intrathoracic blood volume, and right ventricular end diastolic volume as indicators of cardiac preload. J Crit Care 1996;11:180-8.
    • (1996) J Crit Care , vol.11 , pp. 180-188
    • Lichtwarck-Aschoff, M.1    Beale, R.2    Pfeiffer, U.J.3
  • 7
    • 0021347395 scopus 로고
    • Reliability of clinical monitoring to assess blood volume in critically ill patients
    • Shippy CR, Appel PL, Shoemaker WC. Reliability of clinical monitoring to assess blood volume in critically ill patients. Crit Care Med 1984;12:107-12.
    • (1984) Crit Care Med , vol.12 , pp. 107-112
    • Shippy, C.R.1    Appel, P.L.2    Shoemaker, W.C.3
  • 8
    • 0030760843 scopus 로고    scopus 로고
    • New monitors of intravascular volume: A comparison of arterial pressure waveform analysis and the intrathoracic blood volume
    • Preisman S, Pfeiffer U, Lieberman N, Perel A. New monitors of intravascular volume: a comparison of arterial pressure waveform analysis and the intrathoracic blood volume. Intensive Care Med 1997;23:651-7.
    • (1997) Intensive Care Med , vol.23 , pp. 651-657
    • Preisman, S.1    Pfeiffer, U.2    Lieberman, N.3    Perel, A.4
  • 9
    • 0029090208 scopus 로고
    • Continuous measurement of cardiac output with pulse contour analysis
    • Irlbeck M, Forst H, Briegel J, Haller M, Peter K. Continuous measurement of cardiac output with pulse contour analysis. Anesthesist 1995;44:493-500.
    • (1995) Anesthesist , vol.44 , pp. 493-500
    • Irlbeck, M.1    Forst, H.2    Briegel, J.3    Haller, M.4    Peter, K.5
  • 10
    • 0027938298 scopus 로고
    • Is continuous cardiac output measurement using thermodiluition reliable in the critically ill patients?
    • Boldt J, Menges T, Wollbruck M, Hammermann H, Hempelmann G. Is continuous cardiac output measurement using thermodiluition reliable in the critically ill patients? Crit Care Med 1994;22:1913-8.
    • (1994) Crit Care Med , vol.22 , pp. 1913-1918
    • Boldt, J.1    Menges, T.2    Wollbruck, M.3    Hammermann, H.4    Hempelmann, G.5
  • 11
    • 0033935864 scopus 로고    scopus 로고
    • Use of transesophageal Doppler ultrasonography in ventilated pediatric patients: Derivation of cardiac output
    • Tibby SM, Hatherill M, Murdoch IA. Use of transesophageal Doppler ultrasonography in ventilated pediatric patients: derivation of cardiac output. Crit Care Med 2000;28:2045-50.
    • (2000) Crit Care Med , vol.28 , pp. 2045-2050
    • Tibby, S.M.1    Hatherill, M.2    Murdoch, I.A.3
  • 12
    • 0025995952 scopus 로고
    • Effects of alterations in left ventricular filling, contractility, and systemic vascular resistence on the ascending aortic blood velocity waveform of normal subjects
    • Singer M, Allen MJ, Webb AR, Bennett ED. Effects of alterations in left ventricular filling, contractility, and systemic vascular resistence on the ascending aortic blood velocity waveform of normal subjects. Crit Care Med 1991;19:1138-45.
    • (1991) Crit Care Med , vol.19 , pp. 1138-1145
    • Singer, M.1    Allen, M.J.2    Webb, A.R.3    Bennett, E.D.4
  • 13
    • 0031471719 scopus 로고    scopus 로고
    • Clinicians' abilities to estimate cardiac index in ventilated children and infants
    • Tibby SM, Hatherill M, Marsh MJ, Murdoch IA. Clinicians' abilities to estimate cardiac index in ventilated children and infants. Arch Dis Child 1997;77:516-8.
    • (1997) Arch Dis Child , vol.77 , pp. 516-518
    • Tibby, S.M.1    Hatherill, M.2    Marsh, M.J.3    Murdoch, I.A.4
  • 14
    • 0035147673 scopus 로고    scopus 로고
    • Beat-to-beat changes in stroke volume precede the general circulatory effects of mechanical ventilation: A case report
    • Nelson N, Janerot-Sjoberg B. Beat-to-beat changes in stroke volume precede the general circulatory effects of mechanical ventilation: a case report. Crit Care 2001;5:41-5.
    • (2001) Crit Care , vol.5 , pp. 41-45
    • Nelson, N.1    Janerot-Sjoberg, B.2
  • 15
    • 0036219991 scopus 로고    scopus 로고
    • Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery
    • Reuter DA, Felbinger TW, Schnidt C, Kilger E, Godje O, Lamm P et al. Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 2002;28:392-8.
    • (2002) Intensive Care Med , vol.28 , pp. 392-398
    • Reuter, D.A.1    Felbinger, T.W.2    Schnidt, C.3    Kilger, E.4    Godje, O.5    Lamm, P.6
  • 16
    • 0019440777 scopus 로고
    • Mechanical effect of lung distension with positive pressure on cardiac function
    • Marini JJ, Culver BH, Butler J. Mechanical effect of lung distension with positive pressure on cardiac function. Am Rev Respir Dis 1981;124:382-6.
    • (1981) Am Rev Respir Dis , vol.124 , pp. 382-386
    • Marini, J.J.1    Culver, B.H.2    Butler, J.3
  • 17
    • 0029786702 scopus 로고    scopus 로고
    • Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform
    • Pizov R, Cohen M, Weiss Y, Segal E, Cotev S, Perel A. Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform. Crit Care Med 1996;24:1381-7.
    • (1996) Crit Care Med , vol.24 , pp. 1381-1387
    • Pizov, R.1    Cohen, M.2    Weiss, Y.3    Segal, E.4    Cotev, S.5    Perel, A.6
  • 18
    • 0032707398 scopus 로고    scopus 로고
    • Changes in stroke volume cause change in cardiac output in neonates and in children when mean airway pressure is altered
    • Gullberg N, Winberg P. Selld'en H. Changes in stroke volume cause change in cardiac output in neonates and in children when mean airway pressure is altered. Acta Anaesthesiol Scand 1999;43:999-1004.
    • (1999) Acta Anaesthesiol Scand , vol.43 , pp. 999-1004
    • Gullberg, N.1    Winberg, P.2    Selld'en, H.3
  • 19
    • 0035091859 scopus 로고    scopus 로고
    • Are transoesophageal Doppler parameters a reliable guide to paediatric haemodynamic status and fluid management?
    • Tibby SM, Hatherill M, Durward A, Murdoch IA. Are transoesophageal Doppler parameters a reliable guide to paediatric haemodynamic status and fluid management? Intensive Care Med 2001;27:201-5.
    • (2001) Intensive Care Med , vol.27 , pp. 201-205
    • Tibby, S.M.1    Hatherill, M.2    Durward, A.3    Murdoch, I.A.4
  • 20
    • 0032726891 scopus 로고    scopus 로고
    • Pulmonary artery wedge pressure and extravascular lung water in patients with acute cardiogenic pulmonary edema
    • Bindels AJH, van der Hoeven JG, Meinders AE. Pulmonary artery wedge pressure and extravascular lung water in patients with acute cardiogenic pulmonary edema. Am J Cardiol 1999;84:1158-63.
    • (1999) Am J Cardiol , vol.84 , pp. 1158-1163
    • Bindels, A.J.H.1    Van Der Hoeven, J.G.2    Meinders, A.E.3
  • 21
    • 0033818728 scopus 로고    scopus 로고
    • Extravascular lung water in patients with septic shock during a fluid regimen guided by cardiac index
    • Bindels AJGH, van der Hoeven JG, Meinders AE. Extravascular lung water in patients with septic shock during a fluid regimen guided by cardiac index. Neth J Med 2000;57:82-93.
    • (2000) Neth J Med , vol.57 , pp. 82-93
    • Bindels, A.J.G.H.1    Van Der Hoeven, J.G.2    Meinders, A.E.3
  • 23
    • 0026631780 scopus 로고
    • End diastolic volume a better indicator of preload in the critically ill
    • Diebel LN, Wilson RF, Tagett MG, Kline RA. End diastolic volume a better indicator of preload in the critically ill. Arch Surg 1992;127:817-22.
    • (1992) Arch Surg , vol.127 , pp. 817-822
    • Diebel, L.N.1    Wilson, R.F.2    Tagett, M.G.3    Kline, R.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.