Volumn 43, Issue 10, 1999, Pages 999-1004

Changes in stroke volume cause change in cardiac output in neonates and infants when mean airway pressure is altered

Author keywords

Cardiac output; Mean airway pressure; Mechanical ventilation; Neonatal; Pediatric; Stroke volume

Indexed keywords

AIRWAY PRESSURE; ARTICLE; ARTIFICIAL VENTILATION; CLINICAL ARTICLE; HEART OUTPUT; HEART STROKE VOLUME; HUMAN; INFANT; NEWBORN; PEDIATRIC ANESTHESIA; POSITIVE END EXPIRATORY PRESSURE; PRIORITY JOURNAL;

EID: 0032707398     PISSN: 00015172     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1399-6576.1999.431005.x     Document Type: Article
Times cited : (35)

References (17)
  • 1
    • 0015458313 scopus 로고
    • Development of myocardial sympathetic innervation in the fetal lamb
    • Lebowitz EA, Novick JS, Rudolph AM. Development of myocardial sympathetic innervation in the fetal lamb. Pediatr Res 1972: 6: 887-893.
    • (1972) Pediatr Res , vol.6 , pp. 887-893
    • Lebowitz, E.A.1    Novick, J.S.2    Rudolph, A.M.3
  • 2
    • 0009509149 scopus 로고
    • Anesthesia for the pediatric patient
    • Barash PG, Cullen BF, Stoelting RK, eds. Philadelphia: J.B. Lippincott
    • Anesthesia for the pediatric patient. In: Barash PG, Cullen BF, Stoelting RK, eds. Clinical anesthesia. Philadelphia: J.B. Lippincott, 1989.
    • (1989) Clinical Anesthesia
  • 3
    • 0009482879 scopus 로고
    • Anatomy and physiology in relation to pediatric anesthesia
    • Katz J., Steward D, eds. W.B. Saunders
    • Goudsouzian N. Anatomy and physiology in relation to pediatric anesthesia. In: Katz J., Steward D, eds. Anaesthesia and uncommon pediatric diseases, 2nd edn. W.B. Saunders, 1993.
    • (1993) Anaesthesia and Uncommon Pediatric Diseases, 2nd Edn
    • Goudsouzian, N.1
  • 5
    • 0025374497 scopus 로고
    • Left ventricular stroke volume and output in healthy term infants
    • Winberg P, Lundell BP. Left ventricular stroke volume and output in healthy term infants. Am J Perinat 1990: 7: 223-226.
    • (1990) Am J Perinat , vol.7 , pp. 223-226
    • Winberg, P.1    Lundell, B.P.2
  • 6
    • 0026515234 scopus 로고
    • Relationship between heart rate, left ventricular output, and stroke volume in preterm infants during fluctuations in heart rate
    • Winberg P, Ergander U. Relationship between heart rate, left ventricular output, and stroke volume in preterm infants during fluctuations in heart rate. Pediatr Res 1992: 31: 117-120.
    • (1992) Pediatr Res , vol.31 , pp. 117-120
    • Winberg, P.1    Ergander, U.2
  • 8
    • 0023181159 scopus 로고
    • Influence of positive end-expiratory pressure on cardiac performance in premature infants: A Doppler-echocardiographic study
    • Hausdorf G, Hellwege HH. Influence of positive end-expiratory pressure on cardiac performance in premature infants: a Doppler-echocardiographic study. Crit Care Med 1987: 15: 661-664.
    • (1987) Crit Care Med , vol.15 , pp. 661-664
    • Hausdorf, G.1    Hellwege, H.H.2
  • 9
    • 0029680666 scopus 로고    scopus 로고
    • Pressure support ventilation increases cardiac output in neonates and infants
    • Gullberg N, Winberg P, Sellden H. Pressure support ventilation increases cardiac output in neonates and infants. Paediatr Anaesth 1996: 6: 311-315.
    • (1996) Paediatr Anaesth , vol.6 , pp. 311-315
    • Gullberg, N.1    Winberg, P.2    Sellden, H.3
  • 10
    • 0019942435 scopus 로고
    • Noninvasive pulsed Doppler determination of cardiac output in neonates and children
    • Alverson DC, Elridge MV, Yabek SM, Bergman W. Noninvasive pulsed Doppler determination of cardiac output in neonates and children. J Pediatr 1982: 101: 46-50.
    • (1982) J Pediatr , vol.101 , pp. 46-50
    • Alverson, D.C.1    Elridge, M.V.2    Yabek, S.M.3    Bergman, W.4
  • 11
    • 0020402993 scopus 로고
    • Evaluation of pulmonary and systemic bloodflow by 2-dimensional Doppler echocardiography using fast Fourier transform spectral analysis
    • Goldberg S, Sahn DJ, Allen HD, Valdes-Cruz L, Hoenecke H, Carnahan Y. Evaluation of pulmonary and systemic bloodflow by 2-dimensional Doppler echocardiography using fast Fourier transform spectral analysis. Am J Cardiol 1982: 50: 1394-1400.
    • (1982) Am J Cardiol , vol.50 , pp. 1394-1400
    • Goldberg, S.1    Sahn, D.J.2    Allen, H.D.3    Valdes-Cruz, L.4    Hoenecke, H.5    Carnahan, Y.6
  • 12
    • 0023606071 scopus 로고
    • Doppler determination of cardiac output in infants and children: Comparison with simultaneous thermodilution
    • Mellander M, Sabel K-G, Solymar L, Eriksson B. Doppler determination of cardiac output in infants and children: Comparison with simultaneous thermodilution. Pediatr Cardiol 1987: 8: 241-246.
    • (1987) Pediatr Cardiol , vol.8 , pp. 241-246
    • Mellander, M.1    Sabel, K.-G.2    Solymar, L.3    Eriksson, B.4
  • 13
    • 85047677474 scopus 로고
    • Measurement of instantaneous blood-flow velocity in the human aorta using pulsed Doppler ultrasound
    • Gisvold SE, Brubakk AO. Measurement of instantaneous blood-flow velocity in the human aorta using pulsed Doppler ultrasound. Cardiovasc Res 1982: 16: 26-33.
    • (1982) Cardiovasc Res , vol.16 , pp. 26-33
    • Gisvold, S.E.1    Brubakk, A.O.2
  • 14
    • 0024430920 scopus 로고
    • Left ventricular output during postnatal circulatory adaptation in healthy infants born at full term
    • Winberg P, Jansson M, Marions L, Lundell BP. Left ventricular output during postnatal circulatory adaptation in healthy infants born at full term. Arch Dis Child 1989: 64: 1374-1378
    • (1989) Arch Dis Child , vol.64 , pp. 1374-1378
    • Winberg, P.1    Jansson, M.2    Marions, L.3    Lundell, B.P.4
  • 16
    • 0030915185 scopus 로고    scopus 로고
    • Heart rate and cardiac output after atropine in anaesthetised infants and children
    • McAuliffe G, Bissonnette B, Cavalle-Garrido T, Boutin C. Heart rate and cardiac output after atropine in anaesthetised infants and children. Can J Anaesth 1997: 44: 154-159.
    • (1997) Can J Anaesth , vol.44 , pp. 154-159
    • McAuliffe, G.1    Bissonnette, B.2    Cavalle-Garrido, T.3    Boutin, C.4
  • 17
    • 0024604347 scopus 로고
    • Haemodynamic effects of atropine during halothane or isoflurane anaesthesia in infants and small children
    • Murray DJ, Forbes RB, Dillman JB, Mahoney LT, Dull DL. Haemodynamic effects of atropine during halothane or isoflurane anaesthesia in infants and small children. Can J Anaesth 1989: 36: 295-300.
    • (1989) Can J Anaesth , vol.36 , pp. 295-300
    • Murray, D.J.1    Forbes, R.B.2    Dillman, J.B.3    Mahoney, L.T.4    Dull, D.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.