-
1
-
-
0027141149
-
Oxygen in human tumors: Correlations between methods of measurement and response to therapy
-
Summary of a workshop held 19-20 November 1992, at the National Cancer Institute, Bethesda, Maryland
-
Stone HB, Brown JM, Phillips TL, Sutherland RM. (1993). Oxygen in human tumors: correlations between methods of measurement and response to therapy. Summary of a workshop held 19-20 November 1992, at the National Cancer Institute, Bethesda, Maryland. Radiat Res 136:422-434.
-
(1993)
Radiat. Res.
, vol.136
, pp. 422-434
-
-
Stone, H.B.1
Brown, J.M.2
Phillips, T.L.3
Sutherland, R.M.4
-
2
-
-
0038121969
-
HIF and oxygen sensing; as important to life as the air we breathe?
-
Wiesener MS, Maxwell PH. (2003). HIF and oxygen sensing; as important to life as the air we breathe? Ann Med 35:183-190.
-
(2003)
Ann. Med.
, vol.35
, pp. 183-190
-
-
Wiesener, M.S.1
Maxwell, P.H.2
-
3
-
-
0024408986
-
Blood flow, oxygen and nutrient supply, and metabolic microenvironment of human tumors: A review
-
Vaupel P, Kallinowski F, Okunieff P. (1989). Blood flow, oxygen and nutrient supply, and metabolic microenvironment of human tumors: a review. Cancer Res 49:6449-6465.
-
(1989)
Cancer Res.
, vol.49
, pp. 6449-6465
-
-
Vaupel, P.1
Kallinowski, F.2
Okunieff, P.3
-
4
-
-
0017380828
-
The influence of hypoxia and acidity on the hyperthermic response of malignant cells in vitro
-
Overgaard J, Bichel P. (1977). The influence of hypoxia and acidity on the hyperthermic response of malignant cells in vitro. Radiology 123:511-514.
-
(1977)
Radiology
, vol.123
, pp. 511-514
-
-
Overgaard, J.1
Bichel, P.2
-
5
-
-
84960987950
-
The concentration of oxygen dissolved in tissue at the time of irradiation as a factor in radiotherapy
-
Gray LH, Conger AD, Ebert M. (1953). The concentration of oxygen dissolved in tissue at the time of irradiation as a factor in radiotherapy. Br J Radiol 26:638-648.
-
(1953)
Br. J. Radiol.
, vol.26
, pp. 638-648
-
-
Gray, L.H.1
Conger, A.D.2
Ebert, M.3
-
6
-
-
0019349297
-
Classification of antineoplastic agents by their selective toxicities toward oxygenated and hypoxic tumor cells
-
Teicher BA, Lazo JS, Sartorelli AC. (1981). Classification of antineoplastic agents by their selective toxicities toward oxygenated and hypoxic tumor cells. Cancer Res 41:73-81.
-
(1981)
Cancer Res.
, vol.41
, pp. 73-81
-
-
Teicher, B.A.1
Lazo, J.S.2
Sartorelli, A.C.3
-
9
-
-
0029935987
-
Oxygenation in tumors by modified hemoglobins
-
Nozue M, Lee I, Manning JM, Manning LR, Jain RK. (1996). Oxygenation in tumors by modified hemoglobins. J Surg Oncol 62:109-114.
-
(1996)
J. Surg. Oncol.
, vol.62
, pp. 109-114
-
-
Nozue, M.1
Lee, I.2
Manning, J.M.3
Manning, L.R.4
Jain, R.K.5
-
10
-
-
25144505212
-
The measurement of absolute oxygen pressure with the chamber-Pt-electrode in selected media, especially in blood and tissue
-
Kunze K, Luebbers DW, Windisch E. (1963). [The measurement of absolute oxygen pressure with the chamber-Pt-electrode in selected media, especially in blood and tissue]. Pflugers Arch Gesamte Physiol Menschen Tiere 276:415-428.
-
(1963)
Pflugers Arch. Gesamte. Physiol. Menschen Tiere
, vol.276
, pp. 415-428
-
-
Kunze, K.1
Luebbers, D.W.2
Windisch, E.3
-
11
-
-
0004855923
-
An ultramicro oxygen electrode
-
Fatt I. (1964). An ultramicro oxygen electrode. J Appl Physiol 19:326-329.
-
(1964)
J. Appl. Physiol.
, vol.19
, pp. 326-329
-
-
Fatt, I.1
-
12
-
-
0023664339
-
An optical method for measurement of dioxygen concentration based upon quenching of phosphorescence
-
Vanderkooi J, Maniara G, Green T, Wilson D. (1987). An optical method for measurement of dioxygen concentration based upon quenching of phosphorescence. J Biol Chem 262:5476-5482.
-
(1987)
J. Biol. Chem.
, vol.262
, pp. 5476-5482
-
-
Vanderkooi, J.1
Maniara, G.2
Green, T.3
Wilson, D.4
-
13
-
-
0023869404
-
The oxygen dependence of mitochondrial oxidative phosphorylation measured by a new optical method for measuring oxygen concentration
-
Wilson D, Rumsey W, Green T, Vanderkooi J. (1988). The oxygen dependence of mitochondrial oxidative phosphorylation measured by a new optical method for measuring oxygen concentration. J Biol Chem 263:2712-2718.
-
(1988)
J. Biol. Chem.
, vol.263
, pp. 2712-2718
-
-
Wilson, D.1
Rumsey, W.2
Green, T.3
Vanderkooi, J.4
-
14
-
-
0023707206
-
Imaging of phosphorescence: A novel method for measuring oxygen distribution in perfused tissue
-
Rumsey WL, Vanderkooi JM, Wilson DF. (1988). Imaging of phosphorescence: a novel method for measuring oxygen distribution in perfused tissue. Science 241:1649-1651.
-
(1988)
Science
, vol.241
, pp. 1649-1651
-
-
Rumsey, W.L.1
Vanderkooi, J.M.2
Wilson, D.F.3
-
15
-
-
0026724974
-
Localization of tumors and evaluation of their state of oxygenation by phosphorescence imaging
-
Wilson DF, Cerniglia GJ. (1992). Localization of tumors and evaluation of their state of oxygenation by phosphorescence imaging. Cancer Res 52:3988-3993.
-
(1992)
Cancer Res.
, vol.52
, pp. 3988-3993
-
-
Wilson, D.F.1
Cerniglia, G.J.2
-
17
-
-
0029981183
-
Wilson DF. Noninvasive imaging of the distribution in oxygen in tissue in vivo using near-infrared phosphors
-
Vinogradov SA, Lo LW, Jenkins WT, Evans SM, Koch C. Wilson DF. (1996). Noninvasive imaging of the distribution in oxygen in tissue in vivo using near-infrared phosphors. Biophys J 70:1609-1617.
-
(1996)
Biophys. J.
, vol.70
, pp. 1609-1617
-
-
Vinogradov, S.A.1
Lo, L.W.2
Jenkins, W.T.3
Evans, S.M.4
Koch, C.5
-
18
-
-
0038143918
-
Interstitial PO(2) determination by phosphorescence quenching microscopy
-
Smith LM, Golub AS, Pittman RN. (2002). Interstitial PO(2) determination by phosphorescence quenching microscopy. Microcirculation 9:389-395.
-
(2002)
Microcirculation
, vol.9
, pp. 389-395
-
-
Smith, L.M.1
Golub, A.S.2
Pittman, R.N.3
-
19
-
-
0033749513
-
Luminescence lifetime imaging of oxygen, pH and carbon dioxide distribution using optical sensors
-
Liebsch G, Klimant I, Frank B, Holst G, Wolfbeis OS. (2000). Luminescence lifetime imaging of oxygen, pH and carbon dioxide distribution using optical sensors. Appl Spectrosc 54:548-559.
-
(2000)
Appl. Spectrosc.
, vol.54
, pp. 548-559
-
-
Liebsch, G.1
Klimant, I.2
Frank, B.3
Holst, G.4
Wolfbeis, O.S.5
-
20
-
-
0035448978
-
Fluorescent imaging of pH with optical sensors using time domain dual lifetime referencing
-
Liebsch G, Klimant I, Krause C, Wolfbeis OS. (2001). Fluorescent imaging of pH with optical sensors using time domain dual lifetime referencing. Anal Chem 73:4354-4363.
-
(2001)
Anal. Chem.
, vol.73
, pp. 4354-4363
-
-
Liebsch, G.1
Klimant, I.2
Krause, C.3
Wolfbeis, O.S.4
-
21
-
-
2942563759
-
Method for time-resolved luminescence imaging of hydrogen peroxide rising sensor membranes in a microwell format
-
Schaeferling M, Wu M, Enderlein J, Bauer H, Wolfbeis OS. (2003). Method for time-resolved luminescence imaging of hydrogen peroxide rising sensor membranes in a microwell format. Appl Spectrosc 57:1386-1392.
-
(2003)
Appl. Spectrosc.
, vol.57
, pp. 1386-1392
-
-
Schaeferling, M.1
Wu, M.2
Enderlein, J.3
Bauer, H.4
Wolfbeis, O.S.5
-
22
-
-
0028982332
-
Fiber optic microsensors, a new tool in aquatic biology
-
Klimant I, Meyer V, Kuehl M. (1995). Fiber optic microsensors, a new tool in aquatic biology. Limnol Oceanogr 40:1159.
-
(1995)
Limnol. Oceanogr.
, vol.40
, pp. 1159
-
-
Klimant, I.1
Meyer, V.2
Kuehl, M.3
-
23
-
-
84910217368
-
Transplantable tumors of the Syrian (golden) hamsters, I: Tumors of the alimentary tract, endocrine glands and melanomas
-
Fortner JG, Mahy AG, Schrodt GR. (1961). Transplantable tumors of the Syrian (golden) hamsters, I: tumors of the alimentary tract, endocrine glands and melanomas. Cancer Res 21:161-198.
-
(1961)
Cancer Res.
, vol.21
, pp. 161-198
-
-
Fortner, J.G.1
Mahy, A.G.2
Schrodt, G.R.3
-
24
-
-
0019122176
-
Technical report: A new chamber technique for microvascular studies in unanesthetized hamsters
-
Endrich B, Asaishi K, Gotz A, Messmer K. (1980). Technical report: a new chamber technique for microvascular studies in unanesthetized hamsters. Res Exp Med 177:125-134.
-
(1980)
Res. Exp. Med.
, vol.177
, pp. 125-134
-
-
Endrich, B.1
Asaishi, K.2
Gotz, A.3
Messmer, K.4
-
25
-
-
0028792555
-
Effects of photodynamic therapy on leucocyte-endothelium interaction: Differences between normal and tumour tissue
-
Dellian M, Abels C, Kuhnle GE, Goetz AE. (1995). Effects of photodynamic therapy on leucocyte-endothelium interaction: differences between normal and tumour tissue. Br J Cancer 72:1125-1130.
-
(1995)
Br. J. Cancer
, vol.72
, pp. 1125-1130
-
-
Dellian, M.1
Abels, C.2
Kuhnle, G.E.3
Goetz, A.E.4
-
26
-
-
0031239841
-
Effects of diaspirin-cross-linked hemoglobin (DCLHb) on local tissue oxygen tension in striated skin muscle: An efficacy study in the hamster
-
Nolte D, Steinhauser P, Pickelmann S, Berger S, Hartl R, Messmer K. (1997). Effects of diaspirin-cross-linked hemoglobin (DCLHb) on local tissue oxygen tension in striated skin muscle: an efficacy study in the hamster. J Lab Clin Med 130:328-338.
-
(1997)
J. Lab. Clin. Med.
, vol.130
, pp. 328-338
-
-
Nolte, D.1
Steinhauser, P.2
Pickelmann, S.3
Berger, S.4
Hartl, R.5
Messmer, K.6
-
28
-
-
0020065252
-
Microcirculatory blood flow, capillary morphology and local oxygen pressure of the hamster amelanotic melanoma A-Mel-3
-
Endrich B, Hammersen F, Gotz A, Messmer K. (1982). Microcirculatory blood flow, capillary morphology and local oxygen pressure of the hamster amelanotic melanoma A-Mel-3. J Natl Cancer Inst 68:475-485.
-
(1982)
J. Natl. Cancer Inst.
, vol.68
, pp. 475-485
-
-
Endrich, B.1
Hammersen, F.2
Gotz, A.3
Messmer, K.4
-
29
-
-
0037767279
-
Tissue window chamber system for validation of implanted oxygen sensors
-
Makale MT, Lin JT, Calou RE, Tsai AG, Chen PC, Gough DA. (2003). Tissue window chamber system for validation of implanted oxygen sensors. Am J Physiol Heart Circ Physiol 284:H2288-H2294.
-
(2003)
Am. J. Physiol. Heart Circ. Physiol.
, vol.284
-
-
Makale, M.T.1
Lin, J.T.2
Calou, R.E.3
Tsai, A.G.4
Chen, P.C.5
Gough, D.A.6
-
31
-
-
0037288430
-
pO(2) measurements by phosphorescence quenching: Characteristics and applications of an automated system
-
Kerger H, Groth G, Kalenka A, Vajkoczy P, Tsai AG, Intaglietta M. (2003). pO(2) measurements by phosphorescence quenching: characteristics and applications of an automated system. Microvasc Res 65:32-38.
-
(2003)
Microvasc. Res.
, vol.65
, pp. 32-38
-
-
Kerger, H.1
Groth, G.2
Kalenka, A.3
Vajkoczy, P.4
Tsai, A.G.5
Intaglietta, M.6
-
34
-
-
0031057084
-
Microvascular oxygen delivery and interstitial oxygenation during sodium pentobarbital anesthesia
-
Kerger H, Saltzman DJ, Gonzales A, Tsai AG, van Ackern K, Winslow RM, Intaglietta M. (1997). Microvascular oxygen delivery and interstitial oxygenation during sodium pentobarbital anesthesia. Anesthesiology 86:372-386.
-
(1997)
Anesthesiology
, vol.86
, pp. 372-386
-
-
Kerger, H.1
Saltzman, D.J.2
Gonzales, A.3
Tsai, A.G.4
van Ackern, K.5
Winslow, R.M.6
Intaglietta, M.7
-
35
-
-
0038413636
-
Effects of light fractionation and different fluence rates on photodynamic therapy with 5-aminolaevulinic acid in vivo
-
Babilas P, Schacht V, Liebsch G, Wolfbeis OS, Landthaler M, Szcimies RM, Abels C. (2003). Effects of light fractionation and different fluence rates on photodynamic therapy with 5-aminolaevulinic acid in vivo. Br J Cancer 88:1462-1469.
-
(2003)
Br. J. Cancer
, vol.88
, pp. 1462-1469
-
-
Babilas, P.1
Schacht, V.2
Liebsch, G.3
Wolfbeis, O.S.4
Landthaler, M.5
Szcimies, R.M.6
Abels, C.7
-
36
-
-
0030673038
-
Oxygen flux fluorescence lifetime imaging
-
Hartmann P, Ziegler W, Holst G, Lübbers DW. (1997). Oxygen flux fluorescence lifetime imaging. Sensors and Actuators B38(1-3):110-115.
-
(1997)
Sensors and Actuators
, vol.B38
, Issue.1-3
, pp. 110-115
-
-
Hartmann, P.1
Ziegler, W.2
Holst, G.3
Lübbers, D.W.4
-
37
-
-
0033359360
-
Luminescence lifetime temperature sensing based on sol-gels and poly(acrylonitrile) dyed with ruthenium metal ligand complexes
-
Liebsch G, Klimant I, Wolfbeis OS. (1999). Luminescence lifetime temperature sensing based on sol-gels and poly(acrylonitrile) dyed with ruthenium metal ligand complexes. Adv Mat 11:1296-1299.
-
(1999)
Adv. Mat.
, vol.11
, pp. 1296-1299
-
-
Liebsch, G.1
Klimant, I.2
Wolfbeis, O.S.3
-
38
-
-
33751155786
-
Effects of polymer matrices on the time-resolved luminescence of a ruthenium complex quenched by oxygen
-
Draxler S, Lippitsch ME, Klimant I, Kraus H, Wolfbeis OS. (1995). Effects of polymer matrices on the time-resolved luminescence of a ruthenium complex quenched by oxygen. J Phys Chem 99:3162-3167.
-
(1995)
J. Phys. Chem.
, vol.99
, pp. 3162-3167
-
-
Draxler, S.1
Lippitsch, M.E.2
Klimant, I.3
Kraus, H.4
Wolfbeis, O.S.5
-
39
-
-
0031833649
-
Localized hypothermia: Impact on oxygenation, microregional perfusion, metabolic and bioenergetic status of subcutaneous rat tumours
-
Kelleher DK, Nauth C, Thews O, Krueger W, Vaupel P. (1998). Localized hypothermia: impact on oxygenation, microregional perfusion, metabolic and bioenergetic status of subcutaneous rat tumours. Br J Cancer 78:56-61.
-
(1998)
Br. J. Cancer
, vol.78
, pp. 56-61
-
-
Kelleher, D.K.1
Nauth, C.2
Thews, O.3
Krueger, W.4
Vaupel, P.5
-
40
-
-
0026579114
-
A comparative study of the temperature dependence of the oxygen-binding properties of mammalian hemoglobins
-
Coletta M, Clementi ME, Ascenzi P, Petruzzelli R, Condo SC, Giardina B. (1992). A comparative study of the temperature dependence of the oxygen-binding properties of mammalian hemoglobins. Eur J Biochem 204:1155-1157.
-
(1992)
Eur. J. Biochem.
, vol.204
, pp. 1155-1157
-
-
Coletta, M.1
Clementi, M.E.2
Ascenzi, P.3
Petruzzelli, R.4
Condo, S.C.5
Giardina, B.6
-
41
-
-
0027244512
-
Temperature dependence of oxygen diffusion and consumption in mammalian striated muscle
-
Bentley TB, Meng H, Pittman RN. (1993). Temperature dependence of oxygen diffusion and consumption in mammalian striated muscle. Am J Physiol 264:H1825-H1830.
-
(1993)
Am. J. Physiol.
, vol.264
-
-
Bentley, T.B.1
Meng, H.2
Pittman, R.N.3
-
42
-
-
0029897602
-
Oxygen tension profiles in isolated hamster retractor muscle at different temperatures
-
Dutta A, Wang L, Meng H, Pittman RN, Popel AS. (1996). Oxygen tension profiles in isolated hamster retractor muscle at different temperatures. Microvasc Res 51:288-302.
-
(1996)
Microvasc. Res.
, vol.51
, pp. 288-302
-
-
Dutta, A.1
Wang, L.2
Meng, H.3
Pittman, R.N.4
Popel, A.S.5
-
43
-
-
0030975754
-
Influence of temperature on oxygen diffusion in hamster retractor muscle
-
Bentley TB, Pittman RN. (1997). Influence of temperature on oxygen diffusion in hamster retractor muscle. Am J Physiol 272:H1106-H1112.
-
(1997)
Am. J. Physiol.
, vol.272
-
-
Bentley, T.B.1
Pittman, R.N.2
-
44
-
-
0023811399
-
Responses of the microcirculation to hot and cold environments
-
Grayson J. (1988). Responses of the microcirculation to hot and cold environments. Pharmacol Ther 38:201-214.
-
(1988)
Pharmacol. Ther.
, vol.38
, pp. 201-214
-
-
Grayson, J.1
-
45
-
-
1642536758
-
Noninvasive measurement of microvascular and interstitial oxygen profiles in a human tumor in SCID mice
-
Torres Filho IP, Leunig M, Yuan F, Intaglietta M, Jain RK. (1994). Noninvasive measurement of microvascular and interstitial oxygen profiles in a human tumor in SCID mice. Proc Natl Acad Sci USA 91:2081-2085.
-
(1994)
Proc. Natl. Acad. Sci. USA
, vol.91
, pp. 2081-2085
-
-
Torres Filho, I.P.1
Leunig, M.2
Yuan, F.3
Intaglietta, M.4
Jain, R.K.5
-
46
-
-
0037112619
-
Oxyphor R2 and G2: Phosphors for measuring oxygen by oxygen-dependent quenching of phosphorescence
-
Dunphy I, Vinogradov SA, Wilson DF. (2002). Oxyphor R2 and G2: phosphors for measuring oxygen by oxygen-dependent quenching of phosphorescence. Anal Biochem 310:191-198.
-
(2002)
Anal. Biochem.
, vol.310
, pp. 191-198
-
-
Dunphy, I.1
Vinogradov, S.A.2
Wilson, D.F.3
-
48
-
-
0028004275
-
In vivo visualization of oxygen transport in microvascular network
-
Itoh T, Yaegashi K, Kosaka T, Kinoshita T, Morimoto T. (1994). In vivo visualization of oxygen transport in microvascular network. Am J Physiol 267:H2068-H2078.
-
(1994)
Am. J. Physiol.
, vol.267
-
-
Itoh, T.1
Yaegashi, K.2
Kosaka, T.3
Kinoshita, T.4
Morimoto, T.5
-
49
-
-
0032130948
-
FLIM of luminescent oxygen sensors: Clinical applications and results
-
Stücker M, Schulze L, Pott G, Hartmann P, Lübbers DW, Röchling A, Altmeyer P. (1998). FLIM of luminescent oxygen sensors: clinical applications and results. Sensors and Actuators B51:171-175.
-
(1998)
Sensors and Actuators
, vol.B51
, pp. 171-175
-
-
Stücker, M.1
Schulze, L.2
Pott, G.3
Hartmann, P.4
Lübbers, D.W.5
Röchling, A.6
Altmeyer, P.7
|