-
1
-
-
0033066711
-
A review of the complications and results of implantation of the AMS artificial urinary sphincter
-
Hajivassiliou CA. A review of the complications and results of implantation of the AMS artificial urinary sphincter. European Urol 1999; 35:36-44.
-
(1999)
European Urol
, vol.35
, pp. 36-44
-
-
Hajivassiliou, C.A.1
-
2
-
-
0033835451
-
Artificial urethral sphincter for incontinence
-
Petrou SP, Elliott DS, Barrett DM. Artificial urethral sphincter for incontinence. Urology 2000; 56:353-9.
-
(2000)
Urology
, vol.56
, pp. 353-359
-
-
Petrou, S.P.1
Elliott, D.S.2
Barrett, D.M.3
-
3
-
-
0023201997
-
Implantation of artificial sphincter for anal incontinence
-
Christiansen J, Lorentzen M. Implantation of artificial sphincter for anal incontinence. Lancet 1987; 1:244-5.
-
(1987)
Lancet
, vol.1
, pp. 244-245
-
-
Christiansen, J.1
Lorentzen, M.2
-
4
-
-
0029752788
-
Results of artificial sphincter in severe anal incontinence. Report of 14 consecutive implantations
-
Lehur PA, Michot F, Denis P, Grise P, Leborgne J, Teniere P, Buzelin JM. Results of artificial sphincter in severe anal incontinence. Report of 14 consecutive implantations. Dis Colon Rectum 1996; 39:1352-5.
-
(1996)
Dis Colon Rectum
, vol.39
, pp. 1352-1355
-
-
Lehur, P.A.1
Michot, F.2
Denis, P.3
Grise, P.4
Leborgne, J.5
Teniere, P.6
Buzelin, J.M.7
-
6
-
-
0032508233
-
Clinical, physiological, and radiological study of a new purpose-designed artificial bowel sphincter
-
Vaizey CJ, Kamm MA, Gold DM, Bartram CI, Halligan S, Nicholls RJ. Clinical, physiological, and radiological study of a new purpose-designed artificial bowel sphincter. The Lancet 1998; 352:105-9.
-
(1998)
The Lancet
, vol.352
, pp. 105-109
-
-
Vaizey, C.J.1
Kamm, M.A.2
Gold, D.M.3
Bartram, C.I.4
Halligan, S.5
Nicholls, R.J.6
-
7
-
-
0033884281
-
Artificial anal sphincter: Prospective clinical and manometric evaluation
-
Lehur PA, Roig JV, Duinslaeger M. Artificial anal sphincter: Prospective clinical and manometric evaluation. Dis Colon Rectum 2000; 43:1100-6.
-
(2000)
Dis Colon Rectum
, vol.43
, pp. 1100-1106
-
-
Lehur, P.A.1
Roig, J.V.2
Duinslaeger, M.3
-
8
-
-
0036105130
-
Comparison of quality of life and anorectal function after artificial sphincter implantation
-
Lehur PA, Frank Z, Michel N, Pascal G, Stanislas BV. Comparison of quality of life and anorectal function after artificial sphincter implantation. Dis Colon Rectum 2002; 45:508-13.
-
(2002)
Dis Colon Rectum
, vol.45
, pp. 508-513
-
-
Lehur, P.A.1
Frank, Z.2
Michel, N.3
Pascal, G.4
Stanislas, B.V.5
-
9
-
-
0031148289
-
Biomechanical evaluation of an artificial anal sphincter prosthesis
-
Hajivassiliou CA, Carter KB, Finlay IG. Biomechanical evaluation of an artificial anal sphincter prosthesis. J Med Eng Tech 1997; 21:89-95.
-
(1997)
J Med Eng Tech
, vol.21
, pp. 89-95
-
-
Hajivassiliou, C.A.1
Carter, K.B.2
Finlay, I.G.3
-
10
-
-
0031212796
-
Development of an artificial urethral valve using SMA actuators
-
Chonan S, Jian ZW, Tani J, Orikasa S, Tanahashi Y, Takagi T, Tanaka M, Tanikawa J. Development of an artificial urethral valve using SMA actuators. Smart Mater Struct 1997; 6:410-4.
-
(1997)
Smart Mater Struct
, vol.6
, pp. 410-414
-
-
Chonan, S.1
Jian, Z.W.2
Tani, J.3
Orikasa, S.4
Tanahashi, Y.5
Takagi, T.6
Tanaka, M.7
Tanikawa, J.8
-
11
-
-
0034932367
-
Development of an implantable artificial anal sphincter by the use of the shape memory alloy (SMA)
-
Amae S, Wada M, Luo Y, Nakamura H, Yoshida S, Kamiyama T, Yambe T, Takagi T, Nitta S, Ohi R. Development of an implantable artificial anal sphincter by the use of the shape memory alloy (SMA). ASAIO J 2001; 47:346-50.
-
(2001)
ASAIO J
, vol.47
, pp. 346-350
-
-
Amae, S.1
Wada, M.2
Luo, Y.3
Nakamura, H.4
Yoshida, S.5
Kamiyama, T.6
Yambe, T.7
Takagi, T.8
Nitta, S.9
Ohi, R.10
-
12
-
-
3142703022
-
Functional evaluation of an artificial anal sphincter using shape memory alloys
-
Luo Y, Takagi T, Okuyama T, Amae S, Wada M, Nishi K, Kamiyama T, Yambe T, Matsuki H. Functional evaluation of an artificial anal sphincter using shape memory alloys. ASAIO J 2004; 50:338-43.
-
(2004)
ASAIO J
, vol.50
, pp. 338-343
-
-
Luo, Y.1
Takagi, T.2
Okuyama, T.3
Amae, S.4
Wada, M.5
Nishi, K.6
Kamiyama, T.7
Yambe, T.8
Matsuki, H.9
-
13
-
-
0039171080
-
An overview of nitinol medical applications
-
Duerig T, Pelton A, Stoeckel D. An overview of nitinol medical applications. Mat Sci Engin 1999;A273-275:149-60.
-
(1999)
Mat Sci Engin
, vol.A273-275
, pp. 149-160
-
-
Duerig, T.1
Pelton, A.2
Stoeckel, D.3
-
14
-
-
0001944155
-
General application of SMA's and smart materials
-
Otsuka K, Wayman CM, eds. Cambridge University Press
-
Melton KN. General application of SMA's and smart materials. In: Otsuka K, Wayman CM, eds. Shape Memory Materials. Cambridge University Press, 1998:220-34.
-
(1998)
Shape Memory Materials
, pp. 220-234
-
-
Melton, K.N.1
-
16
-
-
0021526318
-
Effect of heat treatment on the all-round shape memory effect in Ti-51at%Ni
-
Nishida M, Honma T. Effect of heat treatment on the all-round shape memory effect in Ti-51at%Ni. Scripta Metallurgica 1984; 18:1299-302.
-
(1984)
Scripta Metallurgica
, vol.18
, pp. 1299-1302
-
-
Nishida, M.1
Honma, T.2
-
17
-
-
13844256844
-
Thermal control of SMA artificial anal sphincters for complete implantation
-
Luo Y, Okuyama T, Takagi T, Kamiyama T, Nishi K, Yambe T. Thermal control of SMA artificial anal sphincters for complete implantation. Smart Mat Struc 2005; 14:29-35.
-
(2005)
Smart Mat Struc
, vol.14
, pp. 29-35
-
-
Luo, Y.1
Okuyama, T.2
Takagi, T.3
Kamiyama, T.4
Nishi, K.5
Yambe, T.6
-
18
-
-
0019068816
-
Anodic polarization behavior of Ti-Ni and Ti-6A1-4V in simulated physiological solutions
-
Speck K, Fraker A. Anodic polarization behavior of Ti-Ni and Ti-6A1-4V in simulated physiological solutions. J Dent Res 1980; 59:1590.
-
(1980)
J Dent Res
, vol.59
, pp. 1590
-
-
Speck, K.1
Fraker, A.2
|