메뉴 건너뛰기




Volumn 14, Issue 1, 2005, Pages 29-35

Thermal control of shape memory alloy artificial anal sphincters for complete implantation

Author keywords

[No Author keywords available]

Indexed keywords

ACTUATORS; DIFFERENTIAL SCANNING CALORIMETRY; ELASTICITY; HEAT TREATMENT; IMPLANTS (SURGICAL); SHAPE MEMORY EFFECT; SWITCHES; THERMAL EFFECTS;

EID: 13844256844     PISSN: 09641726     EISSN: None     Source Type: Journal    
DOI: 10.1088/0964-1726/14/1/003     Document Type: Article
Times cited : (15)

References (17)
  • 1
    • 0002116097 scopus 로고
    • ed T W Duerig, K N Melton, D Stockel and C M Wayman (London: Butterworth-Heinemann)
    • Kapgan M and Melton K N 1990 Engineering Aspects of Shape Memory Alloys ed T W Duerig, K N Melton, D Stockel and C M Wayman (London: Butterworth-Heinemann) pp 137-48
    • (1990) Engineering Aspects of Shape Memory Alloys , pp. 137-148
    • Kapgan, M.1    Melton, K.N.2
  • 2
    • 0003012680 scopus 로고    scopus 로고
    • ed K Otuska and C M Wayman (Cambridge: Cambridge University Press)
    • Ohkata I and Suzuki Y 1998 Shape Memory Materials ed K Otuska and C M Wayman (Cambridge: Cambridge University Press) pp 240-66
    • (1998) Shape Memory Materials , pp. 240-266
    • Ohkata, I.1    Suzuki, Y.2
  • 4
    • 0041364536 scopus 로고    scopus 로고
    • Modeling and numerical simulation on thermomechanical behavior of SMA plates with two-way shape memory effect
    • Takagi T, Luo Y, Suzuki S, Matsumoto M and Tani J 2002 Modeling and numerical simulation on thermomechanical behavior of SMA plates with two-way shape memory effect J. Intell. Mater. Syst. Struct. 12 721-8
    • (2002) J. Intell. Mater. Syst. Struct. , vol.12 , pp. 721-728
    • Takagi, T.1    Luo, Y.2    Suzuki, S.3    Matsumoto, M.4    Tani, J.5
  • 9
    • 0036577938 scopus 로고    scopus 로고
    • An SMA artificial anal sphincter actuated by transcutaneous energy transmission systems
    • Luo Y, Takagi T, Amae S, Wada M, Yambe T, Kamiyama T and Matsuki H 2002 An SMA artificial anal sphincter actuated by transcutaneous energy transmission systems Mater. Trans. 43 1052-6
    • (2002) Mater. Trans. , vol.43 , pp. 1052-1056
    • Luo, Y.1    Takagi, T.2    Amae, S.3    Wada, M.4    Yambe, T.5    Kamiyama, T.6    Matsuki, H.7
  • 10
    • 0033066711 scopus 로고    scopus 로고
    • A review of the complications and results of implantation of the AMS artificial urinary sphincter
    • Hajivassiliou C A 1999 A review of the complications and results of implantation of the AMS artificial urinary sphincter Eur. Urol. 35 36-44
    • (1999) Eur. Urol. , vol.35 , pp. 36-44
    • Hajivassiliou, C.A.1
  • 11
    • 0033835451 scopus 로고    scopus 로고
    • Artificial urethral sphincter for incontinence
    • Petrou S P, Elliott D S and Barrett D M 2000 Artificial urethral sphincter for incontinence Urology 56 353-9
    • (2000) Urology , vol.56 , pp. 353-359
    • Petrou, S.P.1    Elliott, D.S.2    Barrett, D.M.3
  • 13
  • 14
    • 0032508233 scopus 로고    scopus 로고
    • Clinical, physiological, and radiological study of a new purpose-designed artificial bowel sphincter
    • Vaizey C J, Kamm M A, Gold D M, Bartram C I, Halligan S and Nocholls R J 1998 Clinical, physiological, and radiological study of a new purpose-designed artificial bowel sphincter Lancet 352 105-9
    • (1998) Lancet , vol.352 , pp. 105-109
    • Vaizey, C.J.1    Kamm, M.A.2    Gold, D.M.3    Bartram, C.I.4    Halligan, S.5    Nocholls, R.J.6
  • 16
    • 0009695881 scopus 로고
    • Development of transcutaneous energy transmission system
    • ed T Akutsu (Tokyo: Springer)
    • Mitamura Y, Hirano A, Okamoto E and Mikami T 1988 Development of transcutaneous energy transmission system Artificial Heat-2 ed T Akutsu (Tokyo: Springer) pp 265-70
    • (1988) Artificial Heat-2 , pp. 265-270
    • Mitamura, Y.1    Hirano, A.2    Okamoto, E.3    Mikami, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.