메뉴 건너뛰기




Volumn 4, Issue 3, 2005, Pages 181-182

Balloon breast brachytherapy - Review of current data

Author keywords

[No Author keywords available]

Indexed keywords

BALLOON CATHETER; BRACHYTHERAPY; BREAST CARCINOMA; CANCER RADIOTHERAPY; DOSIMETRY; ESTHETICS; HUMAN; INTERMETHOD COMPARISON; IRRADIATION; MEDICAL DECISION MAKING; MEDICAL SOCIETY; PRIORITY JOURNAL; REVIEW; SAFETY; STANDARDIZATION; TREATMENT INDICATION; TREATMENT OUTCOME;

EID: 25144431739     PISSN: 15384721     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.brachy.2005.07.003     Document Type: Editorial
Times cited : (9)

References (15)
  • 1
    • 4744361569 scopus 로고    scopus 로고
    • Defining the clinical target volume for patients with early-stage breast cancer treated with lumpectomy and accelerated partial breast irradiation: A pathologic analysis
    • F.A. Vicini, L.L. Kestin, and N.S. Goldstein Defining the clinical target volume for patients with early-stage breast cancer treated with lumpectomy and accelerated partial breast irradiation: A pathologic analysis Int J Radiat Oncol Biol Phys 60 2004 722 730
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 722-730
    • Vicini, F.A.1    Kestin, L.L.2    Goldstein, N.S.3
  • 2
    • 4544233332 scopus 로고    scopus 로고
    • Prone accelerated partial breast irradiation after breast-conserving surgery: Preliminary clinical results and dose-volume histogram analysis
    • S.C. Formenti, M.T. Truong, and J.D. Goldberg Prone accelerated partial breast irradiation after breast-conserving surgery: Preliminary clinical results and dose-volume histogram analysis Int J Radiat Oncol Biol Phys 60 2004 493 504
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 493-504
    • Formenti, S.C.1    Truong, M.T.2    Goldberg, J.D.3
  • 3
    • 3543068740 scopus 로고    scopus 로고
    • MammoSite and interstitial brachytherapy for accelerated partial breast irradiation: Factors that affect toxicity and cosmesis
    • N.M. Shah, T. Tenenholz, and D. Arthur MammoSite and interstitial brachytherapy for accelerated partial breast irradiation: Factors that affect toxicity and cosmesis Cancer 101 2004 727 734
    • (2004) Cancer , vol.101 , pp. 727-734
    • Shah, N.M.1    Tenenholz, T.2    Arthur, D.3
  • 4
    • 3042606187 scopus 로고    scopus 로고
    • 3D CT-based high-dose-rate breast brachytherapy implants: Treatment planning and quality assurance
    • R.K. Das, R. Patel, and H. Shah 3D CT-based high-dose-rate breast brachytherapy implants: Treatment planning and quality assurance Int J Radiat Oncol Biol Phys 59 2004 1224 1228
    • (2004) Int J Radiat Oncol Biol Phys , vol.59 , pp. 1224-1228
    • Das, R.K.1    Patel, R.2    Shah, H.3
  • 5
    • 4344628403 scopus 로고    scopus 로고
    • Lumpectomy plus tamoxifen with or without irradiation in women 70 years of age or older with early breast cancer
    • K.S. Hughes, L.A. Schnaper, and D. Berry Lumpectomy plus tamoxifen with or without irradiation in women 70 years of age or older with early breast cancer N Engl J Med 351 2004 971 977
    • (2004) N Engl J Med , vol.351 , pp. 971-977
    • Hughes, K.S.1    Schnaper, L.A.2    Berry, D.3
  • 6
    • 4344707888 scopus 로고    scopus 로고
    • Tamoxifen with or without breast irradiation in women 50 years of age or older with early breast cancer
    • A.W. Fyles, D.R. McCready, and L.A. Manchul Tamoxifen with or without breast irradiation in women 50 years of age or older with early breast cancer N Engl J Med 351 2004 963 970
    • (2004) N Engl J Med , vol.351 , pp. 963-970
    • Fyles, A.W.1    McCready, D.R.2    Manchul, L.A.3
  • 7
    • 18844386778 scopus 로고    scopus 로고
    • The MammoSite breast applicator: A review of technique and outcomes
    • A. Dickler, M.C. Kirk, and J. Chu The MammoSite breast applicator: A review of technique and outcomes Brachytherapy 4 2005 130 136
    • (2005) Brachytherapy , vol.4 , pp. 130-136
    • Dickler, A.1    Kirk, M.C.2    Chu, J.3
  • 8
    • 0037085979 scopus 로고    scopus 로고
    • Dosimetric characteristics of the MammoSite RTS, a new breast brachytherapy applicator
    • G.K. Edmundson, F.A. Vicini, and P.Y. Chen Dosimetric characteristics of the MammoSite RTS, a new breast brachytherapy applicator Int J Radiat Oncol Biol Phys 52 2002 1132 1139
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 1132-1139
    • Edmundson, G.K.1    Vicini, F.A.2    Chen, P.Y.3
  • 9
    • 25144445067 scopus 로고    scopus 로고
    • Dose overestimation in balloon catheter brachytherapy for breast cancer
    • S. Ye, R. Ove, and S. Shen Dose overestimation in balloon catheter brachytherapy for breast cancer Int J Radiat Oncol Biol Phys 60 2004 S272 S273
    • (2004) Int J Radiat Oncol Biol Phys , vol.60
    • Ye, S.1    Ove, R.2    Shen, S.3
  • 10
    • 11144346797 scopus 로고    scopus 로고
    • Acute complications of MammoSite brachytherapy: A single institution's initial clinical experience
    • J.L. Harper, J.M. Jenrette, and K.N. Vanek Acute complications of MammoSite brachytherapy: A single institution's initial clinical experience Int J Radiat Oncol Biol Phys 61 2005 169 174
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 169-174
    • Harper, J.L.1    Jenrette, J.M.2    Vanek, K.N.3
  • 11
    • 6944228080 scopus 로고    scopus 로고
    • Acute toxicity of high-dose-rate intracavitary brachytherapy with the MammoSite applicator in patients with early-stage breast cancer
    • Richards GM, Berson AM, Rescigno J, et al. Acute toxicity of high-dose-rate intracavitary brachytherapy with the MammoSite applicator in patients with early-stage breast cancer. Ann Surg Oncol 11:739-746.
    • Ann Surg Oncol , vol.11 , pp. 739-746
    • Richards, G.M.1    Berson, A.M.2    Rescigno, J.3
  • 12
    • 4944259342 scopus 로고    scopus 로고
    • Partial breast irradiation in breast conserving therapy by way of interstitial brachytherapy
    • P.R. Benitez, P.Y. Chen, and F.A. Vicini Partial breast irradiation in breast conserving therapy by way of interstitial brachytherapy Am J Surg 188 2004 355 364
    • (2004) Am J Surg , vol.188 , pp. 355-364
    • Benitez, P.R.1    Chen, P.Y.2    Vicini, F.A.3
  • 13
    • 12944259304 scopus 로고    scopus 로고
    • Thirty month results with the Mammosite breast brachytherapy applicator: Cosmesis, toxicity and local control in partial breast irradiation
    • M. Keisch, F. Vicini, and T. Scroggins Thirty month results with the Mammosite breast brachytherapy applicator: Cosmesis, toxicity and local control in partial breast irradiation Int J Radiat Oncol Biol Phys 60 2004 S272
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 272
    • Keisch, M.1    Vicini, F.2    Scroggins, T.3
  • 14
    • 25144461329 scopus 로고    scopus 로고
    • Mammosite brachytherapy: Balloon to skin distance not best predictor of cosmesis
    • C. Quiet, V. Zannis, and R. Kuske Mammosite brachytherapy: Balloon to skin distance not best predictor of cosmesis Breast Cancer Res Treat 88 2004 S166
    • (2004) Breast Cancer Res Treat , vol.88 , pp. 166
    • Quiet, C.1    Zannis, V.2    Kuske, R.3
  • 15
    • 25144465214 scopus 로고    scopus 로고
    • First analysis of patient demographics and technical reproducibility by the American Society of Breast Surgeons (ASBS) Mammosite breast brachytherapy registry trial in 801 patients treated with accelerated partial breast irradiation (APBI)
    • F.A. Vicini, P. Beitsch, and C. Quiet First analysis of patient demographics and technical reproducibility by the American Society of Breast Surgeons (ASBS) Mammosite breast brachytherapy registry trial in 801 patients treated with accelerated partial breast irradiation (APBI) Breast Cancer Res Treat 88 2004 S171
    • (2004) Breast Cancer Res Treat , vol.88 , pp. 171
    • Vicini, F.A.1    Beitsch, P.2    Quiet, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.