메뉴 건너뛰기




Volumn 5749, Issue , 2005, Pages 348-358

A preliminary investigation of ambient light in the interventional fluoroscopy laboratory

Author keywords

Ambient light; Fluoroscopy; Interventional procedures; Viewing conditions

Indexed keywords

CARDIOLOGY; DISPLAY DEVICES; FLUORESCENT SCREENS; IMAGE ENHANCEMENT; IMAGE QUALITY; LABORATORIES; LIGHT; LIGHT SOURCES; LIGHTING; LIQUID CRYSTAL DISPLAYS; PHOTOGRAPHY; REFLECTION; TECHNOLOGICAL FORECASTING; THREE DIMENSIONAL;

EID: 24644469127     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.593701     Document Type: Conference Paper
Times cited : (6)

References (28)
  • 1
    • 0034859401 scopus 로고    scopus 로고
    • In the eyes of the beholder: What we see is not what we get
    • Abdullah BJ, Ng KH, In the eyes of the beholder: what we see is not what we get. Br J Radiol, 2001. 74(884): p. 675-6.
    • (2001) Br J Radiol , vol.74 , Issue.884 , pp. 675-676
    • Abdullah, B.J.1    Ng, K.H.2
  • 2
    • 2542602946 scopus 로고    scopus 로고
    • AAPM/RSNA tutorial on equipment selection: PACS equipment overview: Display systems
    • Badano A, AAPM/RSNA tutorial on equipment selection: PACS equipment overview: display systems. Radiographics, 2004. 24(3): p. 879-89.
    • (2004) Radiographics , vol.24 , Issue.3 , pp. 879-889
    • Badano, A.1
  • 3
    • 0142120878 scopus 로고    scopus 로고
    • Angular dependence of the luminance and contrast in medical monochrome liquid crystal displays
    • Badano A, Flynn MJ, Martin S, Kanicki J, Angular dependence of the luminance and contrast in medical monochrome liquid crystal displays. Med Phys, 2003. 30(10): p. 2602-13.
    • (2003) Med Phys , vol.30 , Issue.10 , pp. 2602-2613
    • Badano, A.1    Flynn, M.J.2    Martin, S.3    Kanicki, J.4
  • 4
    • 0016203098 scopus 로고
    • Radiographic viewing conditions
    • Balter S, Janower ML, Radiographic Viewing Conditions. Proc SPIE, 1973. 43: p. 225-226.
    • (1973) Proc SPIE , vol.43 , pp. 225-226
    • Balter, S.1    Janower, M.L.2
  • 6
    • 0032150493 scopus 로고    scopus 로고
    • Effect of different background lighting conditions on diagnostic performance of digital and film images
    • Cederberg RA, Frederiksen NL, Benson BW, Shulman JD, Effect of different background lighting conditions on diagnostic performance of digital and film images. Dentomaxillofac Radiol, 1998. 27(5): p. 293-7.
    • (1998) Dentomaxillofac Radiol , vol.27 , Issue.5 , pp. 293-297
    • Cederberg, R.A.1    Frederiksen, N.L.2    Benson, B.W.3    Shulman, J.D.4
  • 7
    • 0032588495 scopus 로고    scopus 로고
    • Image quality degradation by light scattering in display devices
    • Flynn MJ, Badano A, Image quality degradation by light scattering in display devices. J Digit Imaging, 1999. 12(2): p. 50-9.
    • (1999) J Digit Imaging , vol.12 , Issue.2 , pp. 50-59
    • Flynn, M.J.1    Badano, A.2
  • 8
    • 19244382193 scopus 로고    scopus 로고
    • Impact of ambient light and window settings on the detectability of catheters on soft-copy display of chest radiographs at bedside
    • Fuchsjager MH, Schaefer-Prokop CM, Eisenhuber E, et al., Impact of ambient light and window settings on the detectability of catheters on soft-copy display of chest radiographs at bedside. AJR Am J Roentgenol, 2003. 181(5): p. 1415-21.
    • (2003) AJR Am J Roentgenol , vol.181 , Issue.5 , pp. 1415-1421
    • Fuchsjager, M.H.1    Schaefer-Prokop, C.M.2    Eisenhuber, E.3
  • 9
    • 4143115534 scopus 로고    scopus 로고
    • Effect of monitor luminance and ambient light on observer performance in softcopy reading of digital chest radiographs
    • Goo JM, Choi JY, Im JG, et al., Effect of monitor luminance and ambient light on observer performance in softcopy reading of digital chest radiographs. Radiology, 2004. 232(3): p. 762-6.
    • (2004) Radiology , vol.232 , Issue.3 , pp. 762-766
    • Goo, J.M.1    Choi, J.Y.2    Im, J.G.3
  • 10
    • 0036562472 scopus 로고    scopus 로고
    • Influence of room lighting on grey-scale perception with a CRT-and a TFT monitor display
    • Haak R, Wicht MJ, Hellmich M, Nowak G, Noack MJ, Influence of room lighting on grey-scale perception with a CRT-and a TFT monitor display. Dentomaxillofac Radiol, 2002. 31(3): p. 193-7.
    • (2002) Dentomaxillofac Radiol , vol.31 , Issue.3 , pp. 193-197
    • Haak, R.1    Wicht, M.J.2    Hellmich, M.3    Nowak, G.4    Noack, M.J.5
  • 11
    • 0024716774 scopus 로고
    • Environmental designs for reading from imaging work stations: Ergonomic and architectural features
    • Horii SC, Horii HN, Mun SK, Benson HR, Zeman RK, Environmental designs for reading from imaging work stations: ergonomic and architectural features. J Digit Imaging, 1989. 2(3): p. 156-62.
    • (1989) J Digit Imaging , vol.2 , Issue.3 , pp. 156-162
    • Horii, S.C.1    Horii, H.N.2    Mun, S.K.3    Benson, H.R.4    Zeman, R.K.5
  • 12
    • 0037231261 scopus 로고    scopus 로고
    • Influence of monitor luminance change on observer performance for detection of abnormalities depicted on chest radiographs
    • Ikeda M, Ishigaki T, Shimamoto K, et al., Influence of monitor luminance change on observer performance for detection of abnormalities depicted on chest radiographs. Invest Radiol, 2003. 38(1): p. 57-63.
    • (2003) Invest Radiol , vol.38 , Issue.1 , pp. 57-63
    • Ikeda, M.1    Ishigaki, T.2    Shimamoto, K.3
  • 13
    • 0031040180 scopus 로고    scopus 로고
    • Effects of ambient light and view box luminance on the detection of calcifications in mammography
    • Kimme-Smith C, Haus AG, DeBruhl N, Bassett LW, Effects of ambient light and view box luminance on the detection of calcifications in mammography. AJR Am J Roentgenol, 1997. 168(3): p. 775-8.
    • (1997) AJR Am J Roentgenol , vol.168 , Issue.3 , pp. 775-778
    • Kimme-Smith, C.1    Haus, A.G.2    Debruhl, N.3    Bassett, L.W.4
  • 14
    • 0029920750 scopus 로고    scopus 로고
    • Quality assurance measures within DIN 6856: The adaptation of film viewing boxes and their specifications in the radiology department of a university hospital
    • Deutsche Industrie-Norm
    • Kirchner J, Kollath J, [Quality assurance measures within DIN 6856: the adaptation of film viewing boxes and their specifications in the radiology department of a university hospital. Deutsche Industrie-Norm]. Rofo, 1996. 164(2): p. 146-9.
    • (1996) Rofo , vol.164 , Issue.2 , pp. 146-149
    • Kirchner, J.1    Kollath, J.2
  • 15
    • 0028344556 scopus 로고
    • Effect of ambient lighting on the diagnostic efficiency of display screen workplaces
    • Klein HM, Stargardt A, Grehl T, Glaser KH, Gunther RW, [Effect of ambient lighting on the diagnostic efficiency of display screen workplaces]. Rofo, 1994. 160(2): p. 168-72.
    • (1994) Rofo , vol.160 , Issue.2 , pp. 168-172
    • Klein, H.M.1    Stargardt, A.2    Grehl, T.3    Glaser, K.H.4    Gunther, R.W.5
  • 16
    • 0028954458 scopus 로고
    • Update on the recommended viewing protocol for FAXIL threshold contrast detail detectability test objects used in television fluoroscopy
    • Launders JH, McArdle S, Workman A, Cowen AR, Update on the recommended viewing protocol for FAXIL threshold contrast detail detectability test objects used in television fluoroscopy. Br J Radiol, 1995. 68(805): p. 70-7.
    • (1995) Br J Radiol , vol.68 , Issue.805 , pp. 70-77
    • Launders, J.H.1    McArdle, S.2    Workman, A.3    Cowen, A.R.4
  • 17
    • 19044400944 scopus 로고    scopus 로고
    • Softcopy display quality assurance program at Texas Children's Hospital
    • Ly CK, SoftCopy Display Quality Assurance Program at Texas Children's Hospital. J Digit Imaging, 2002. 15 Suppl 1: p. 33-40.
    • (2002) J Digit Imaging , vol.15 , Issue.1 SUPPL. , pp. 33-40
    • Ly, C.K.1
  • 18
    • 0037307004 scopus 로고    scopus 로고
    • Viewing conditions for diagnostic images in three major Dublin hospitals: A comparison with WHO and CEC recommendations
    • McCarthy E, Brennan PC, Viewing conditions for diagnostic images in three major Dublin hospitals: a comparison with WHO and CEC recommendations. Br J Radiol, 2003. 76(902): p. 94-7.
    • (2003) Br J Radiol , vol.76 , Issue.902 , pp. 94-97
    • McCarthy, E.1    Brennan, P.C.2
  • 19
    • 0030266058 scopus 로고    scopus 로고
    • Contrast perception across changes in luminance and spatial frequency
    • Peli E, Arend L, Labianca AT, Contrast perception across changes in luminance and spatial frequency. J Opt Soc Am A, 1996. 13(10): p. 1953-9.
    • (1996) J Opt Soc Am A , vol.13 , Issue.10 , pp. 1953-1959
    • Peli, E.1    Arend, L.2    Labianca, A.T.3
  • 20
    • 0035438404 scopus 로고    scopus 로고
    • Evaluation of a flat CRT monitor for use in radiology
    • Roehrig H, Krupinski EA, Furukawa T, Evaluation of a flat CRT monitor for use in radiology. J Digit Imaging, 2001. 14(3): p. 142-8.
    • (2001) J Digit Imaging , vol.14 , Issue.3 , pp. 142-148
    • Roehrig, H.1    Krupinski, E.A.2    Furukawa, T.3
  • 21
    • 24644459207 scopus 로고    scopus 로고
    • Detectability of catheters on bedside chest radiographs: Comparison between liquid crystal display and high-resolution cathode-ray tube monitors
    • epub ahead of print
    • Scharitzer M, Prokop M, Weber M, Fuchsjager M, Oschatz E, Schaefer-Prokop C, Detectability of Catheters on Bedside Chest Radiographs: Comparison between Liquid Crystal Display and High-Resolution Cathode-Ray Tube Monitors. Radiology, 2004 (epub ahead of print)
    • (2004) Radiology
    • Scharitzer, M.1    Prokop, M.2    Weber, M.3    Fuchsjager, M.4    Oschatz, E.5    Schaefer-Prokop, C.6
  • 22
    • 3042591064 scopus 로고    scopus 로고
    • Assessment of monitor conditions for the display of radiological diagnostic images and ambient lighting
    • Wade C, Brennan PC, Assessment of monitor conditions for the display of radiological diagnostic images and ambient lighting. Br J Radiol, 2004. 77(918): p. 465-71.
    • (2004) Br J Radiol , vol.77 , Issue.918 , pp. 465-471
    • Wade, C.1    Brennan, P.C.2
  • 23
    • 0346906978 scopus 로고    scopus 로고
    • Proposal of a quality-index or metric for soft copy display systems: Contrast sensitivity study
    • Wang J, Compton K, Peng Q, Proposal of a quality-index or metric for soft copy display systems: contrast sensitivity study. J Digit Imaging, 2003. 16(2): p. 185-202.
    • (2003) J Digit Imaging , vol.16 , Issue.2 , pp. 185-202
    • Wang, J.1    Compton, K.2    Peng, Q.3
  • 24
    • 0031260636 scopus 로고    scopus 로고
    • A brief review of human perception factors in digital displays for picture archiving and communications systems
    • Wang J, Langer S, A brief review of human perception factors in digital displays for picture archiving and communications systems. J Digit Imaging, 1997. 10(4): p. 158-68.
    • (1997) J Digit Imaging , vol.10 , Issue.4 , pp. 158-168
    • Wang, J.1    Langer, S.2
  • 28
    • 84861237428 scopus 로고    scopus 로고
    • Last accessed 8 Jan 2005
    • IBM, http://www.pc.ibm.com/ww/healthycomputing, Last accessed 8 Jan 2005


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.