Volumn 109, Issue 17, 2004, Pages 2092-2096

Decision Guidelines for Prophylactic Replacement of Björk-Shiley Convexo-Concave Heart Valves: Impact on Clinical Practice

Author keywords

Follow up studies; Prevention; Prosthesis; Surgery; Valves

Indexed keywords

ADULT; AGED; ARTICLE; BJOERK SHILEY VALVE PROSTHESIS; CALCULATION; CLINICAL PRACTICE; COHORT ANALYSIS; COMPARATIVE STUDY; FEMALE; FOLLOW UP; HUMAN; LIFE EXPECTANCY; MAJOR CLINICAL STUDY; MALE; MEDICAL DECISION MAKING; MORTALITY; OUTCOMES RESEARCH; PRACTICE GUIDELINE; PRIORITY JOURNAL; PROPHYLAXIS; REOPERATION; RETROSPECTIVE STUDY; RISK ASSESSMENT; SAFETY; SURVIVAL; TREATMENT INDICATION;

EID: 2442589796     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.0000125853.51637.C8     Document Type: Article
Times cited : (14)

References (24)
  • 1
    • 0026609494 scopus 로고
    • Should patients with Bjork-Shiley valves undergo prophylactic replacement?
    • Birkmeyer JD, Marrin CA, O'Connor GT. Should patients with Bjork-Shiley valves undergo prophylactic replacement? Lancet. 1992;340: 520-523.
    • (1992) Lancet , vol.340 , pp. 520-523
    • Birkmeyer, J.D.1    Marrin, C.A.2    O'Connor, G.T.3
  • 2
    • 0026490580 scopus 로고
    • Strut fracture with Bjork-Shiley 70 degrees convexo-concave valve: An international multi-institutional follow-up study
    • Ericsson A, Lindblom D, Semb G, et al. Strut fracture with Bjork-Shiley 70 degrees convexo-concave valve: an international multi-institutional follow-up study. Eur J Cardiothorac Surg. 1992;6:339-346.
    • (1992) Eur J Cardiothorac Surg , vol.6 , pp. 339-346
    • Ericsson, A.1    Lindblom, D.2    Semb, G.3
  • 3
    • 0022929935 scopus 로고
    • Mechanical failure of the Bjork-Shiley valve: Incidence, clinical presentation, and management
    • Lindblom D, Bjork VO, Semb BK. Mechanical failure of the Bjork-Shiley valve: incidence, clinical presentation, and management. J Thorac Cardiovasc Surg. 1986;92:894-907.
    • (1986) J Thorac Cardiovasc Surg , vol.92 , pp. 894-907
    • Lindblom, D.1    Bjork, V.O.2    Semb, B.K.3
  • 4
    • 0034757328 scopus 로고    scopus 로고
    • Outlet strut fracture of Bjork-Shiley convexo concave heart valves: The UK Cohort Study
    • Omar RZ, Morton LS, Halliday DA, et al. Outlet strut fracture of Bjork-Shiley convexo concave heart valves: the UK Cohort Study. Heart. 2001;86:57-62.
    • (2001) Heart , vol.86 , pp. 57-62
    • Omar, R.Z.1    Morton, L.S.2    Halliday, D.A.3
  • 5
  • 6
    • 0027212167 scopus 로고
    • Age thresholds for prophylactic replacement of Björk-Shiley convexo-concave heart valves: A clinical and economic evaluation
    • van der Meulen JH, Steyerberg EW, van der Graaf Y, et al. Age thresholds for prophylactic replacement of Björk-Shiley convexo-concave heart valves: a clinical and economic evaluation. Circulation. 1993;88:156-164.
    • (1993) Circulation , vol.88 , pp. 156-164
    • Van Der Meulen, J.H.1    Steyerberg, E.W.2    Van Der Graaf, Y.3
  • 7
    • 0030459227 scopus 로고    scopus 로고
    • Welder identity, weld date, and the risk of outlet strut fracture in Björk-Shiley convexo-concave valves: The Dutch Cohort Study
    • Kallewaard M, Algra A, van der Graaf Y. Welder identity, weld date, and the risk of outlet strut fracture in Björk-Shiley convexo-concave valves: the Dutch Cohort Study. Heart. 1996;76:510-512.
    • (1996) Heart , vol.76 , pp. 510-512
    • Kallewaard, M.1    Algra, A.2    Van Der Graaf, Y.3
  • 8
    • 0029662215 scopus 로고    scopus 로고
    • Prophylactic replacement of Björk-Shiley convexo-concave heart valves: An easy-to-use tool to aid decision-making in individual patients
    • Steyerberg EW, van der Meulen JH, van Herwerden LA, et al. Prophylactic replacement of Björk-Shiley convexo-concave heart valves: an easy-to-use tool to aid decision-making in individual patients. Heart. 1996;76:264-268.
    • (1996) Heart , vol.76 , pp. 264-268
    • Steyerberg, E.W.1    Van Der Meulen, J.H.2    Van Herwerden, L.A.3
  • 9
    • 0032940087 scopus 로고    scopus 로고
    • Which manufacturing characteristics are predictors of outlet strut fracture in large sixty-degree Björk-Shiley convexo-concave mitral valves?
    • The Bjork-Shiley Study Group
    • Kallewaard M, Algra A, Defauw J, et al. Which manufacturing characteristics are predictors of outlet strut fracture in large sixty-degree Björk-Shiley convexo-concave mitral valves? The Bjork-Shiley Study Group. J Thorac Cardiovasc Surg. 1999;117:766-775.
    • (1999) J Thorac Cardiovasc Surg , vol.117 , pp. 766-775
    • Kallewaard, M.1    Algra, A.2    Defauw, J.3
  • 10
    • 0033985946 scopus 로고    scopus 로고
    • Decision analyses for prophylactic replacement of the Björk-Shiley convexo-concave heart valve: An evaluation of assumptions and estimates
    • Steyerberg EW, Kallewaard M, van der Graaf Y, et al. Decision analyses for prophylactic replacement of the Björk-Shiley convexo-concave heart valve: an evaluation of assumptions and estimates. Med Decis Making. 2000;20:20-32.
    • (2000) Med Decis Making , vol.20 , pp. 20-32
    • Steyerberg, E.W.1    Kallewaard, M.2    Van Der Graaf, Y.3
  • 11
    • 0027423182 scopus 로고
    • Effect of clinical guidelines on medical practice: A systematic review of rigorous evaluations
    • Grimshaw JM, Russell IT. Effect of clinical guidelines on medical practice: a systematic review of rigorous evaluations. Lancet. 1993;342: 1317-1322.
    • (1993) Lancet , vol.342 , pp. 1317-1322
    • Grimshaw, J.M.1    Russell, I.T.2
  • 12
    • 0033585883 scopus 로고    scopus 로고
    • Clinical guidelines: Potential benefits, limitations, and harms of clinical guidelines
    • Woolf SH, Grol R, Hutchinson A, et al. Clinical guidelines: potential benefits, limitations, and harms of clinical guidelines. BMJ. 1999;318: 527-530.
    • (1999) BMJ , vol.318 , pp. 527-530
    • Woolf, S.H.1    Grol, R.2    Hutchinson, A.3
  • 13
    • 0034149491 scopus 로고    scopus 로고
    • Long-term survival after valve replacement with Björk-Shiley CC valves: Björk-Shiley Study Group
    • Kallewaard M, Algra A, Defauw J, et al. Long-term survival after valve replacement with Björk-Shiley CC valves: Björk-Shiley Study Group. Am J Cardiol. 2000;85:598-603.
    • (2000) Am J Cardiol , vol.85 , pp. 598-603
    • Kallewaard, M.1    Algra, A.2    Defauw, J.3
  • 15
    • 0035170927 scopus 로고    scopus 로고
    • Relapses, recurrences, valve replacements, and mortality during the long-term follow-up after infective endocarditis
    • Mansur AJ, Dal Bo CM, Fukushima JT, et al. Relapses, recurrences, valve replacements, and mortality during the long-term follow-up after infective endocarditis. Am Heart J. 2001;141:78-86.
    • (2001) Am Heart J , vol.141 , pp. 78-86
    • Mansur, A.J.1    Dal Bo, C.M.2    Fukushima, J.T.3
  • 17
    • 0026706306 scopus 로고
    • Long-term complications of native valve infective endocarditis in non-addicts a 15-year follow-up study
    • Tomos MP, Permanyer-Miralda G, Olona M, et al. Long-term complications of native valve infective endocarditis in non-addicts a 15-year follow-up study. Ann Intern Med. 1992;117:567-572.
    • (1992) Ann Intern Med , vol.117 , pp. 567-572
    • Tomos, M.P.1    Permanyer-Miralda, G.2    Olona, M.3
  • 18
    • 0035077236 scopus 로고    scopus 로고
    • Risks of fracture of Björk-Shiley 60 degree convexo-concave prosthetic heart valves: Long-term cohort follow up in the UK, Netherlands and USA
    • Blot WJ, Omar RZ, Kallewaard M, et al. Risks of fracture of Björk-Shiley 60 degree convexo-concave prosthetic heart valves: long-term cohort follow up in the UK, Netherlands and USA. J Heart Valve Dis. 2001;10: 202-209.
    • (2001) J Heart Valve Dis , vol.10 , pp. 202-209
    • Blot, W.J.1    Omar, R.Z.2    Kallewaard, M.3
  • 19
    • 0038207177 scopus 로고    scopus 로고
    • Twenty year comparison of a Björk-Shiley mechanical heart valve with porcine bioprostheses
    • Oxenham H, Bloomfield P, Wheatley DJ, et al. Twenty year comparison of a Björk-Shiley mechanical heart valve with porcine bioprostheses. Heart. 2003;89:715-721.
    • (2003) Heart , vol.89 , pp. 715-721
    • Oxenham, H.1    Bloomfield, P.2    Wheatley, D.J.3
  • 20
    • 0142042820 scopus 로고    scopus 로고
    • Clinical prediction rule for 30-day mortality in Bjork-Shiley convexo-concave valve replacement
    • van Gorp MJ, Steyerberg EW, Kallewaard M, et al. Clinical prediction rule for 30-day mortality in Bjork-Shiley convexo-concave valve replacement. J Clin Epidemiol. 2003;56:1006-1012.
    • (2003) J Clin Epidemiol , vol.56 , pp. 1006-1012
    • Van Gorp, M.J.1    Steyerberg, E.W.2    Kallewaard, M.3
  • 21
    • 0031468064 scopus 로고    scopus 로고
    • Psychological distress among recipients of Björk-Shiley convexo-concave valves: The impact of information
    • Kallewaard M, Defauw J, van der Graaf Y. Psychological distress among recipients of Björk-Shiley convexo-concave valves: the impact of information. Heart. 1997;78:577-580.
    • (1997) Heart , vol.78 , pp. 577-580
    • Kallewaard, M.1    Defauw, J.2    Van Der Graaf, Y.3
  • 22
    • 0031017667 scopus 로고    scopus 로고
    • Clinical prediction rules: A review and suggested modifications of methodological standards
    • Laupacis A, Sekar N, Stiell IG. Clinical prediction rules: a review and suggested modifications of methodological standards. JAMA. 1997;277: 488-494.
    • (1997) JAMA , vol.277 , pp. 488-494
    • Laupacis, A.1    Sekar, N.2    Stiell, I.G.3
  • 23
    • 0035955033 scopus 로고    scopus 로고
    • Validity of the Agency for Healthcare Research and Quality clinical practice guidelines: How quickly do guidelines become outdated?
    • Shekelle PG, Ortiz E, Rhodes S, et al. Validity of the Agency for Healthcare Research and Quality clinical practice guidelines: how quickly do guidelines become outdated? JAMA. 2001;286:1461-1467.
    • (2001) JAMA , vol.286 , pp. 1461-1467
    • Shekelle, P.G.1    Ortiz, E.2    Rhodes, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.