메뉴 건너뛰기




Volumn 70, Issue 6, 2004, Pages 697-705

Threonine-FX dosimeter for food irradiation

Author keywords

Food irradiation dosimetry; FX solution; Spectrophotometric readout; Threonine dosimeter

Indexed keywords

AMMONIUM COMPOUNDS; CELLS; DOSIMETERS; OXIDATION; SPECTROPHOTOMETRY; SULFURIC ACID;

EID: 2442575915     PISSN: 0969806X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radphyschem.2003.10.008     Document Type: Article
Times cited : (5)

References (20)
  • 1
    • 0038499173 scopus 로고    scopus 로고
    • Standard practice for using the Fricke reference standard dosimetry system
    • American Society for Testing of Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428, USA.
    • ASTM, Standard E1026, 1997. Standard practice for using the Fricke reference standard dosimetry system. Annual Book of Standards, 12.02. American Society for Testing of Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428, USA.
    • (1997) Annual Book of Standards, 12.02
  • 3
    • 0028657426 scopus 로고
    • Kinetics of radiolytic oxidation of ferrous ions in some aqueous aerated systems
    • Gupta B.L. Kinetics of radiolytic oxidation of ferrous ions in some aqueous aerated systems. Radiat. Phys. Chem. 44(6):1994;611
    • (1994) Radiat. Phys. Chem. , vol.44 , Issue.6 , pp. 611
    • Gupta, B.L.1
  • 5
    • 0344353537 scopus 로고
    • Use of glutamine dosimeter for electron beams used in radiation curing
    • Tokyo
    • Gupta, B.L., Nilekani, S.R., 1988. Use of glutamine dosimeter for electron beams used in radiation curing. In: Proceedings Radiation Curing Asia 88, Tokyo, p. 391.
    • (1988) Proceedings Radiation Curing Asia , vol.88 , pp. 391
    • Gupta, B.L.1    Nilekani, S.R.2
  • 9
    • 0022862104 scopus 로고
    • Dose intercomparison for 400-500 keV electrons using FWT-60 film and glutamine (spectrophotometric readout) dosimeters
    • Gupta B.L., Nilekani S.R., Gehringer P., Miller A. Dose intercomparison for 400-500. keV electrons using FWT-60 film and glutamine (spectrophotometric readout) dosimeters Appl. Radiat. Isot. 37(9):1986;965
    • (1986) Appl. Radiat. Isot. , vol.37 , Issue.9 , pp. 965
    • Gupta, B.L.1    Nilekani, S.R.2    Gehringer, P.3    Miller, A.4
  • 11
    • 0040533070 scopus 로고
    • Dosimetry studies in a radiation vulcanisation of natural rubber latex plant
    • Tokyo
    • Gupta, B.L., Bhat, R.M., Nilekani, S.R., 1993. Dosimetry studies in a radiation vulcanisation of natural rubber latex plant. Proc. Rad. Tech. Asia 93, Tokyo, p. 564.
    • (1993) Proc. Rad. Tech. Asia , vol.93 , pp. 564
    • Gupta, B.L.1    Bhat, R.M.2    Nilekani, S.R.3
  • 12
    • 0033106350 scopus 로고    scopus 로고
    • Dose intercomparison between BARC (India) and NPL (UK) using glutamine (spectrophotometric readout) and dichromate dosimeters
    • Gupta B.L., Bhat R.M., Narayan G.R., Nilekani S.R., Sharpe P.H.G., Crossley D.L. Dose intercomparison between BARC (India) and NPL (UK) using glutamine (spectrophotometric readout) and dichromate dosimeters. Radiat. Phys. Chem. 54:1999;301
    • (1999) Radiat. Phys. Chem. , vol.54 , pp. 301
    • Gupta, B.L.1    Bhat, R.M.2    Narayan, G.R.3    Nilekani, S.R.4    Sharpe, P.H.G.5    Crossley, D.L.6
  • 13
    • 0034237353 scopus 로고    scopus 로고
    • Chemical dosimetry techniques for various applications under different geometries
    • Gupta B.L., Bhat R.M., Narayan G.R., Nilekani S.R Chemical dosimetry techniques for various applications under different geometries. Radiat. Phys. Chem. 59:2000;81
    • (2000) Radiat. Phys. Chem. , vol.59 , pp. 81
    • Gupta, B.L.1    Bhat, R.M.2    Narayan, G.R.3    Nilekani, S.R.4
  • 14
    • 0035009289 scopus 로고    scopus 로고
    • Irradiation temperature effect on glutamine (spectrophotometric readout) dosimeter
    • Gupta B.L, Narayan G.R., Nilekani S.R, Bhat R.M. Irradiation temperature effect on glutamine (spectrophotometric readout) dosimeter. Radiat. Phys. Chem. 61:2001;55
    • (2001) Radiat. Phys. Chem. , vol.61 , pp. 55
    • Gupta, B.L.1    Narayan, G.R.2    Nilekani, S.R.3    Bhat, R.M.4
  • 15
    • 0034845601 scopus 로고    scopus 로고
    • Dose intercomparison for Co-60, 10 MeV electrons and bremsstrahlung radiation, using glutamine (spectrophotometric readout) dosimetry at different irradiation temperatures, Radiat
    • Gupta B.L., Nilekani S.R., Narayan G.R., Bhat R.M. Dose intercomparison for Co-60, 10. MeV electrons and bremsstrahlung radiation, using glutamine (spectrophotometric readout) dosimetry at different irradiation temperatures, Radiat Phys. Chem. 62:2001;293
    • (2001) Phys. Chem. , vol.62 , pp. 293
    • Gupta, B.L.1    Nilekani, S.R.2    Narayan, G.R.3    Bhat, R.M.4
  • 16
    • 0028501031 scopus 로고
    • Effect of impurities in xylenol orange on the spectrophotometric readout method for alanine dosimetry
    • Jain V., Gupta B.L. Effect of impurities in xylenol orange on the spectrophotometric readout method for alanine dosimetry. Appl. Radiat. Isot. 45:1994;973
    • (1994) Appl. Radiat. Isot. , vol.45 , pp. 973
    • Jain, V.1    Gupta, B.L.2
  • 17
    • 2442480540 scopus 로고    scopus 로고
    • A new free radical dosimeter for radiation therapy and blood irradiation dosimetry
    • Nilekani S.R., Gupta B.L. A new free radical dosimeter for radiation therapy and blood irradiation dosimetry. J. Med. Phys. 25(3):2000;138
    • (2000) J. Med. Phys. , vol.25 , Issue.3 , pp. 138
    • Nilekani, S.R.1    Gupta, B.L.2
  • 19
    • 0029020997 scopus 로고
    • Pulse radiolysis studies of short lived species in solid amino acids as precursors of radicals detected by ESR
    • Zagorski Z.P., Gladysz K. Pulse radiolysis studies of short lived species in solid amino acids as precursors of radicals detected by ESR. Radiat. Phys. Chem. 45:1995;847
    • (1995) Radiat. Phys. Chem. , vol.45 , pp. 847
    • Zagorski, Z.P.1    Gladysz, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.