Volumn 59, Issue 1, 2000, Pages 81-90

Chemical dosimetry techniques for various applications under different geometries

Author keywords

Chemical dosimetry; FBX dosimeter; Free radical dosimeter; Spectrophotometric readout method

Indexed keywords

BLOOD; DOSIMETERS; ELECTRON IRRADIATION; ELEMENTARY PARTICLE SOURCES; GAMMA RAYS; LATEXES; PARTICLE ACCELERATORS; RADIOISOTOPES; SPECTROPHOTOMETRY;

EID: 0034237353     PISSN: 0969806X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-806X(00)00187-0     Document Type: Article
Times cited : (16)

References (26)
  • 1
    • 0038499173 scopus 로고    scopus 로고
    • Standard practice for using the Fricke reference standard dosimetry system
    • ASTM Standard E1026, American Society for Testing of Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428, USA
    • ASTM Standard E1026, 1997. Standard practice for using the Fricke reference standard dosimetry system. Annual Book of Standards, 12.02. American Society for Testing of Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428, USA.
    • (1997) Annual Book of Standards, 12.02
  • 2
    • 0343457715 scopus 로고    scopus 로고
    • Standard practice for blood irradiation dosimetry
    • ASTM Standard E1939, American Society for Testing of Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428, USA
    • ASTM Standard E1939, 1998. Standard practice for blood irradiation dosimetry. Annual Book of Standards, 12.02. American Society for Testing of Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428, USA.
    • (1998) Annual Book of Standards, 12.02
  • 6
    • 0028657426 scopus 로고
    • Kinetics of radiolytic oxidation of ferrous ions in some aqueous aerated systems
    • Gupta B.L. Kinetics of radiolytic oxidation of ferrous ions in some aqueous aerated systems. Radiat. Phys. Chem. 44:(6):1994;611.
    • (1994) Radiat. Phys. Chem , vol.44 , Issue.6 , pp. 611
    • Gupta, B.L.1
  • 7
    • 0242452407 scopus 로고    scopus 로고
    • Development of chemical dosimeters at BARC
    • Gupta B.L. Development of chemical dosimeters at BARC. ISRAPS Bulletin. 9:(3):1998;3.
    • (1998) ISRAPS Bulletin , vol.9 , Issue.3 , pp. 3
    • Gupta, B.L.1
  • 8
    • 0017892660 scopus 로고
    • Radiation chemistry of the ferrous sulphate-benzoic acid-xylenol orange system
    • Gupta B.L., Bhat R.M., Gomathy K.R., Suseela B. Radiation chemistry of the ferrous sulphate-benzoic acid-xylenol orange system. Radiat. Res. 75:1978;269.
    • (1978) Radiat. Res , vol.75 , pp. 269
    • Gupta, B.L.1    Bhat, R.M.2    Gomathy, K.R.3    Suseela, B.4
  • 11
    • 0033106350 scopus 로고    scopus 로고
    • Dose intercomparison between BARC (India) and NPL (UK) using glutamine (spectrophotometric readout) and dichromate dosimeters
    • Gupta B.L., Bhat R.M., Narayan G.R., Nilekani S.R., Sharpe P.H.G., Crossley D.L. Dose intercomparison between BARC (India) and NPL (UK) using glutamine (spectrophotometric readout) and dichromate dosimeters. Radiat. Phys. Chem. 54:1999;301.
    • (1999) Radiat. Phys. Chem , vol.54 , pp. 301
    • Gupta, B.L.1    Bhat, R.M.2    Narayan, G.R.3    Nilekani, S.R.4    Sharpe, P.H.G.5    Crossley, D.L.6
  • 12
  • 14
    • 0016345238 scopus 로고
    • Consistency of ferrous sulphate-benzoic acid-xylenol orange dosimeter
    • Gupta B.L., Gomathy K.R. Consistency of ferrous sulphate-benzoic acid-xylenol orange dosimeter. Int. J. Appl. Radiat. Isot. 25:1974;509.
    • (1974) Int. J. Appl. Radiat. Isot , vol.25 , pp. 509
    • Gupta, B.L.1    Gomathy, K.R.2
  • 16
    • 0020032303 scopus 로고
    • Use of the FBX dosimeter for the calibration of cobalt-60 and high energy teletherapy machines
    • Gupta B.L., Kini U.R., Bhat R.M., Madhvanath U. Use of the FBX dosimeter for the calibration of cobalt-60 and high energy teletherapy machines. Phys. Med. Biol. 27:1982;235.
    • (1982) Phys. Med. Biol , vol.27 , pp. 235
    • Gupta, B.L.1    Kini, U.R.2    Bhat, R.M.3    Madhvanath, U.4
  • 21
    • 0022862104 scopus 로고
    • Dose intercomparison for 400-500 keV electrons using FWT-60 film and glutamine (spectrophotometric readout) dosimeters
    • Gupta B.L., Nilekani S.R., Gehringer P., Miller A. Dose intercomparison for 400-500 keV electrons using FWT-60 film and glutamine (spectrophotometric readout) dosimeters. Appl. Radiat. Isot. 37:(9):1986;965.
    • (1986) Appl. Radiat. Isot , vol.37 , Issue.9 , pp. 965
    • Gupta, B.L.1    Nilekani, S.R.2    Gehringer, P.3    Miller, A.4
  • 22
    • 0028501031 scopus 로고
    • Effect of impurities in xylenol orange on the spectrophotometric readout method for alanine dosimetry
    • Jain V., Gupta B.L. Effect of impurities in xylenol orange on the spectrophotometric readout method for alanine dosimetry. Appl. Radiat. Isot. 45:1994;973.
    • (1994) Appl. Radiat. Isot , vol.45 , pp. 973
    • Jain, V.1    Gupta, B.L.2
  • 23
    • 0343022108 scopus 로고
    • Use of alanine (spectrophotometric readout) for dosimetry in radiation therapy
    • Narayan G.R., Suseela B., Gupta B.L. Use of alanine (spectrophotometric readout) for dosimetry in radiation therapy. J. Med. Phys. 19:1994;35.
    • (1994) J. Med. Phys , vol.19 , pp. 35
    • Narayan, G.R.1    Suseela, B.2    Gupta, B.L.3
  • 26
    • 0024458193 scopus 로고
    • Alanine dosimetry using a spectrophotometric ferric-xylenol orange complex readout
    • Van Laere K., Buysse J., Berkevens P. Alanine dosimetry using a spectrophotometric ferric-xylenol orange complex readout. Radiat. Phys. Chem. 34:1989;863.
    • (1989) Radiat. Phys. Chem , vol.34 , pp. 863
    • Van Laere, K.1    Buysse, J.2    Berkevens, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.