메뉴 건너뛰기




Volumn 3, Issue 2, 2004, Pages 65-72

Optimization of Gd-DTPA-enhanced balanced turbo field echo sequence in abdominal imaging: A basic study

Author keywords

Balanced turbo field echo; Flow velocity; Gd DTPA; K space ordering; Steady state free precession

Indexed keywords

CONTRAST MEDIUM; GADOLINIUM PENTETATE;

EID: 24344445306     PISSN: 13473182     EISSN: 18802206     Source Type: Journal    
DOI: 10.2463/mrms.3.65     Document Type: Article
Times cited : (1)

References (15)
  • 2
    • 0035184170 scopus 로고    scopus 로고
    • Projection reconstruction balanced fast field echo for interactive real-time cardiac imaging
    • Schaeffter T, Weiss S, Eggers H, Rasche V. Projection reconstruction balanced fast field echo for interactive real-time cardiac imaging. Magn Reson Med 2001;46:1238-1241.
    • (2001) Magn Reson Med , vol.46 , pp. 1238-1241
    • Schaeffter, T.1    Weiss, S.2    Eggers, H.3    Rasche, V.4
  • 3
    • 0034870344 scopus 로고    scopus 로고
    • Steady state free precession magnetic resonance imaging of the heart: Comparison with segmented k-space gradient-echo imaging
    • Plein S, Bloomer TN, Ridgeway TR, Bainbridge GJ, Sivanathan MU. Steady state free precession magnetic resonance imaging of the heart: comparison with segmented k-space gradient-echo imaging. J Magn Reson Imaging 2001;14:230-236.
    • (2001) J Magn Reson Imaging , vol.14 , pp. 230-236
    • Plein, S.1    Bloomer, T.N.2    Ridgeway, T.R.3    Bainbridge, G.J.4    Sivanathan, M.U.5
  • 4
    • 0027505977 scopus 로고
    • Gradient echo imaging: Techniques and acronyms
    • Elster AD. Gradient echo imaging: techniques and acronyms. Radiology 1993;186:1-8.
    • (1993) Radiology , vol.186 , pp. 1-8
    • Elster, A.D.1
  • 5
    • 0025777470 scopus 로고
    • A decoupled coil detector array for fast acquisition in magnetic resonance imaging
    • Kwiat D, Einav S, Navon G. A decoupled coil detector array for fast acquisition in magnetic resonance imaging. Med Phys 1991;18:251-265.
    • (1991) Med Phys , vol.18 , pp. 251-265
    • Kwiat, D.1    Einav, S.2    Navon, G.3
  • 7
    • 0026788427 scopus 로고
    • Chemical shift magnetic resonance imaging: Application in the abdomen and pelvis
    • Mitchell DG, Kim I, Chang TS, et al. Chemical shift magnetic resonance imaging: application in the abdomen and pelvis. TopMagn Reson Imaging 1992;4:46-63.
    • (1992) TopMagn Reson Imaging , vol.4 , pp. 46-63
    • Mitchell, D.G.1    Kim, I.2    Chang, T.S.3
  • 9
    • 0025232486 scopus 로고
    • Steady-state free precession imaging in the presence of motion: Application for improved visualization of the cerebrospinal fluid
    • Haacke EM, Weilopolski PA, Tkach JA. Modic MT. Steady-state free precession imaging in the presence of motion: application for improved visualization of the cerebrospinal fluid. Radiology 1990;175:545-552.
    • (1990) Radiology , vol.175 , pp. 545-552
    • Haacke, E.M.1    Weilopolski, P.A.2    Tkach, J.A.3    Modic, M.T.4
  • 10
    • 84887846797 scopus 로고
    • A study of optiml pulse sequence for enhanced MR imaging with Gd-DTPA
    • Maeda M. A study of optiml pulse sequence for enhanced MR imaging with Gd-DTPA. J Wakayama Med Soc 1991;42:233-243.
    • (1991) J Wakayama Med Soc , vol.42 , pp. 233-243
    • Maeda, M.1
  • 11
    • 0033761360 scopus 로고    scopus 로고
    • 2-weighted fast MR imaging with true FISP versus HASTE: Comparative efficacy in the evaluation of normal fetal brain maturation
    • 2-weighted fast MR imaging with true FISP versus HASTE: comparative efficacy in the evaluation of normal fetal brain maturation. AJR 2000;175:1375-1380.
    • (2000) AJR , vol.175 , pp. 1375-1380
    • Chung, H.W.1    Chen, C.Y.2    Zimmerman, R.A.3    Lee, K.W.4    Lee, C.C.5    Chin, S.C.6
  • 12
    • 0035023617 scopus 로고    scopus 로고
    • Cine MR angiography of the heart with segmented true fast imaging with steady-state precession
    • Carr JC, Simmonetti O, Bundy J, Li D, Pereles S, Finn JP. Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 2001;219:824-834.
    • (2001) Radiology , vol.219 , pp. 824-834
    • Carr, J.C.1    Simmonetti, O.2    Bundy, J.3    Li, D.4    Pereles, S.5    Finn, J.P.6
  • 13
    • 0036830009 scopus 로고    scopus 로고
    • MR assessment of left ventricular function: Quantitative comparison of fast imaging employing steady-state acquisition (FIESTA) with fast gradient cine technique
    • LiW, Stern JS, Mai VM, Pierchala LN, Edelman RR, Prasad PV. MR assessment of left ventricular function: quantitative comparison of fast imaging employing steady-state acquisition (FIESTA) with fast gradient cine technique. J Magn Reson Imaging 2002;16:559-564.
    • (2002) J Magn Reson Imaging , vol.16 , pp. 559-564
    • Li, W.1    Stern, J.S.2    Mai, V.M.3    Pierchala, L.N.4    Edelman, R.R.5    Prasad, P.V.6
  • 14
    • 0027299367 scopus 로고
    • 2 relaxation times from echoplanner MR imaging in the characterization of focal hepatic lesions
    • 2 relaxation times from echoplanner MR imaging in the characterization of focal hepatic lesions. AJR 1993;160:1011-1017.
    • (1993) AJR , vol.160 , pp. 1011-1017
    • Goldberg, M.A.1    Hahn, P.F.2    Saini, S.3
  • 15
    • 0036847421 scopus 로고    scopus 로고
    • Optimization of signal behavior in the transition to driven equibrium in steady-state free precessions
    • Henning J, Speck O, Scheffler K. Optimization of signal behavior in the transition to driven equibrium in steady-state free precessions. Magn Reson Med 2002;48:801-809.
    • (2002) Magn Reson Med , vol.48 , pp. 801-809
    • Henning, J.1    Speck, O.2    Scheffler, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.