Volumn 11, Issue 9, 1998, Pages 874-881

Quantification of aortic regurgitant volume by a newly developed automated cardiac flow measurement method: An in vitro study

Author keywords

[No Author keywords available]

Indexed keywords

AORTA FLOW; AORTA VALVE REGURGITATION; ARTICLE; ASCENDING AORTA; COLOR ULTRASOUND FLOWMETRY; DOPPLER ECHOCARDIOGRAPHY; PULSATILE FLOW;

EID: 0031751172     PISSN: 08947317     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0894-7317(98)70007-0     Document Type: Article
Times cited : (14)

References (17)
  • 1
    • 0021242793 scopus 로고
    • Limitations of qualitative angiographic grading in aortic or mitral regurgitation
    • CH Craft K Lipscomb K Mathis Limitations of qualitative angiographic grading in aortic or mitral regurgitation Am J Cardiol 53 1984 1593 1598
    • (1984) Am J Cardiol , vol.53 , pp. 1593-1598
    • Craft, CH1    Lipscomb, K2    Mathis, K3
  • 2
    • 0021224860 scopus 로고
    • The development of real-time two-dimensional Doppler echocardiography and its clinical significance in acquired valvular diseases
    • R Omoto Y Yokota S Takamoto The development of real-time two-dimensional Doppler echocardiography and its clinical significance in acquired valvular diseases Jpn Heart J 25 1984 325 340
    • (1984) Jpn Heart J , vol.25 , pp. 325-340
    • Omoto, R1    Yokota, Y2    Takamoto, S3
  • 3
    • 0030059191 scopus 로고    scopus 로고
    • Color Doppler flow convergence and effective regurgitant orifice area for evaluating the severity of chronic aortic regurgitation: an animal study
    • T Shiota M Jones RS Heinrich Color Doppler flow convergence and effective regurgitant orifice area for evaluating the severity of chronic aortic regurgitation: an animal study Circulation 93 1996 594 602
    • (1996) Circulation , vol.93 , pp. 594-602
    • Shiota, T1    Jones, M2    Heinrich, RS3
  • 4
    • 0023698346 scopus 로고
    • Instrumentation and physical factors related to visualization of stenotic and regurgitant jets by Doppler color flow mapping
    • DJ. Sahn Instrumentation and physical factors related to visualization of stenotic and regurgitant jets by Doppler color flow mapping J Am Coll Cardiol 12 1989 1354 1365
    • (1989) J Am Coll Cardiol , vol.12 , pp. 1354-1365
    • Sahn, DJ.1
  • 5
    • 0025866463 scopus 로고
    • Effective aortic regurgitant orifice area: description of a method based on the conservation of mass
    • SC Reimold P Ganz JA Bittl Effective aortic regurgitant orifice area: description of a method based on the conservation of mass J Am Coll Cardiol 18 1991 761 768
    • (1991) J Am Coll Cardiol , vol.18 , pp. 761-768
    • Reimold, SC1    Ganz, P2    Bittl, JA3
  • 6
    • 4243772289 scopus 로고
    • A new method for determining cardiac output by flow velocity vector profile derived from color flow mapping
    • M Shakudo J Yoshikawa K Yoshida A new method for determining cardiac output by flow velocity vector profile derived from color flow mapping Circulation 90 1994 I495 [abstract]
    • (1994) Circulation , vol.90 , pp. I495
    • Shakudo, M1    Yoshikawa, J2    Yoshida, K3
  • 7
    • 0343563407 scopus 로고
    • Automatic measurement of forward flow using color Doppler flow integration: in vitro validation in a pulsatile model
    • M Pu H Tsujino PM Vandervoort JD. Thomas Automatic measurement of forward flow using color Doppler flow integration: in vitro validation in a pulsatile model J Am Soc Echocardiogr 8 1995 393 [abstract]
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 393
    • Pu, M1    Tsujino, H2    Vandervoort, PM3    Thomas, JD.4
  • 8
    • 9444275873 scopus 로고
    • Automated flow measurement using spatial and temporal integration of color Doppler data
    • JP Sun WJ Stewart FM Fouad R Christian AL Klein JD. Thomas Automated flow measurement using spatial and temporal integration of color Doppler data Circulation 92 1995 I15 [abstract]
    • (1995) Circulation , vol.92 , pp. I15
    • Sun, JP1    Stewart, WJ2    Fouad, FM3    Christian, R4    Klein, AL5    Thomas, JD.6
  • 9
    • 26144460913 scopus 로고
    • A new method for determining stroke volume by color Doppler flow velocity profile: stability to a positional change of sample area
    • M Shakudo J Yoshikawa T Yagi A new method for determining stroke volume by color Doppler flow velocity profile: stability to a positional change of sample area J Am Soc Echocardiogr 8 1995 394 [abstract]
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 394
    • Shakudo, M1    Yoshikawa, J2    Yagi, T3
  • 10
    • 0029362422 scopus 로고
    • Quantitative measurement of volume flow rate (cardiac output) by the multibeam Doppler method
    • H Tsujino E Shiki M Hirama K. Iinuma Quantitative measurement of volume flow rate (cardiac output) by the multibeam Doppler method J Am Soc Echocardiogr 8 1995 621 630
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 621-630
    • Tsujino, H1    Shiki, E2    Hirama, M3    Iinuma, K.4
  • 11
    • 0021419747 scopus 로고
    • Explososcan: a parallel processing technique for high speed ultrasound imaging with linear phased arrays
    • DP Shattuck MD Weinshenker SW Smith OT. von Ramm Explososcan: a parallel processing technique for high speed ultrasound imaging with linear phased arrays J Acoust Soc Am 75 1984 1273 1282
    • (1984) J Acoust Soc Am , vol.75 , pp. 1273-1282
    • Shattuck, DP1    Weinshenker, MD2    Smith, SW3    von Ramm, OT.4
  • 12
    • 0023792339 scopus 로고
    • Review of hydrodynamic principles for the cardiologist: applications to the study of blood flow and jets by imaging techniques
    • AP Yoganathan EG Cape H Sung FP Williams A. Jimoh Review of hydrodynamic principles for the cardiologist: applications to the study of blood flow and jets by imaging techniques J Am Coll Cardiol 12 1988 1344 1353
    • (1988) J Am Coll Cardiol , vol.12 , pp. 1344-1353
    • Yoganathan, AP1    Cape, EG2    Sung, H3    Williams, FP4    Jimoh, A.5
  • 13
    • 0028025114 scopus 로고
    • Two-dimensional mitral flow velocity profiles in pig models using epicardial Doppler echocardiography
    • WY Kim T Bisgaard SL Nielsen Two-dimensional mitral flow velocity profiles in pig models using epicardial Doppler echocardiography J Am Coll Cardiol 24 1994 532 545
    • (1994) J Am Coll Cardiol , vol.24 , pp. 532-545
    • Kim, WY1    Bisgaard, T2    Nielsen, SL3
  • 14
    • 0343999679 scopus 로고
    • Three-dimensional integration of mitral inflow from digitized Doppler color flow mapping: in vitro validation
    • PG Walker P Walton AP Yoganathan RA. Levine Three-dimensional integration of mitral inflow from digitized Doppler color flow mapping: in vitro validation Circulation 92 1995 I193 [abstract]
    • (1995) Circulation , vol.92 , pp. I193
    • Walker, PG1    Walton, P2    Yoganathan, AP3    Levine, RA.4
  • 15
    • 0030986478 scopus 로고    scopus 로고
    • Calculation of aortic regurgitant volume by a new digital Doppler color flow mapping method: an animal study with quantified chronic aortic regurgitation
    • T Shiota M Jones S Aida Calculation of aortic regurgitant volume by a new digital Doppler color flow mapping method: an animal study with quantified chronic aortic regurgitation J Am Coll Cardiol 30 1997 834 842
    • (1997) J Am Coll Cardiol , vol.30 , pp. 834-842
    • Shiota, T1    Jones, M2    Aida, S3
  • 16
    • 0030946603 scopus 로고    scopus 로고
    • Slice location dependence of aortic regurgitation measurements with MR phase velocity mapping
    • GP Chatzimavroudis PG Walker JN Oshinski Slice location dependence of aortic regurgitation measurements with MR phase velocity mapping Magn Reson Med 37 1997 545 551
    • (1997) Magn Reson Med , vol.37 , pp. 545-551
    • Chatzimavroudis, GP1    Walker, PG2    Oshinski, JN3
  • 17
    • 0026737780 scopus 로고
    • Severity of aortic regurgitation: interstudy reproducibility of measurements with velocity-encoded cine MR imaging
    • MC Dulce GH Mostbeck M O'Sullivian Severity of aortic regurgitation: interstudy reproducibility of measurements with velocity-encoded cine MR imaging Radiology 185 1992 235 240
    • (1992) Radiology , vol.185 , pp. 235-240
    • Dulce, MC1    Mostbeck, GH2    O'Sullivian, M3