메뉴 건너뛰기




Volumn 32, Issue 8, 2005, Pages 2690-2697

Evaluation of edge effect due to phase contrast imaging for mammography

Author keywords

Edge enhancement; Mammography; Phase contrast imaging; Sharpness

Indexed keywords

FIBER OPTIC SENSORS; FREQUENCY RESPONSE; IMAGE ENHANCEMENT; MAMMOGRAPHY; SEED; SPECTRUM ANALYSIS; SYNCHROTRON RADIATION; X RAY TUBES;

EID: 23944481829     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1992087     Document Type: Article
Times cited : (33)

References (22)
  • 2
    • 85027240056 scopus 로고    scopus 로고
    • The technical development of X-ray the phase contrast imaging
    • in Japanese
    • K. Iwata, "The technical development of X-ray the phase contrast imaging," M&E, March, 112-117(2000) (in Japanese).
    • (2000) M&E , vol.MARCH , pp. 112-117
    • Iwata, K.1
  • 3
    • 20844433805 scopus 로고    scopus 로고
    • Phase contrast X-ray imaging
    • in Japanese
    • A. Momose, "Phase contrast X-ray imaging," Synchrotron Radiat. 10(3), 23-35 (1997) (in Japanese).
    • (1997) Synchrotron Radiat. , vol.10 , Issue.3 , pp. 23-35
    • Momose, A.1
  • 5
    • 0005153913 scopus 로고    scopus 로고
    • Phase contrast mammography using a practical mo tube
    • H. Ohara, A. Ishisaka, C. Honda, F. Shimada, and T. Endo, "Phase Contrast Mammography Using a Practical Mo Tube," Radiology, 217(P), 165 (2000).
    • (2000) Radiology , vol.217 , Issue.P , pp. 165
    • Ohara, H.1    Ishisaka, A.2    Honda, C.3    Shimada, F.4    Endo, T.5
  • 7
    • 0036033437 scopus 로고    scopus 로고
    • Image quality in digital phase contrast imaging using a tungsten anode X-ray tube with a small focal spot size
    • H. Ohara, C. Honda, A. Ishisaka, and F. Shimada, "Image quality in digital phase contrast imaging using a tungsten anode X-ray tube with a small focal spot size," Proceedings SPIE Conference on physics of medial imaging, Vol. 4682, 713-723 (2002).
    • (2002) Proceedings SPIE Conference on Physics of Medial Imaging , vol.4682 , pp. 713-723
    • Ohara, H.1    Honda, C.2    Ishisaka, A.3    Shimada, F.4
  • 8
    • 0002520458 scopus 로고    scopus 로고
    • Phase-sensitive X-ray imaging
    • R. Fizgeral, "Phase-sensitive X-ray imaging," Phys. Today, July 23-26 (2000).
    • (2000) Phys. Today , vol.JULY , pp. 23-26
    • Fizgeral, R.1
  • 10
    • 0033982850 scopus 로고    scopus 로고
    • Human carcinoma: Early experience with phase-contrast X-ray CT with synchrotron radiation? Comparative specimen study with optical microscopy
    • T. Takeda, A. Momose, K. Hirano, S. Haraoka, T. Watanabe, and Y. Itai, "Human carcinoma: Early experience with phase-contrast X-ray CT with synchrotron radiation? comparative specimen study with optical microscopy," Radiology, 214, 298-301 (2000).
    • (2000) Radiology , vol.214 , pp. 298-301
    • Takeda, T.1    Momose, A.2    Hirano, K.3    Haraoka, S.4    Watanabe, T.5    Itai, Y.6
  • 11
    • 0032703734 scopus 로고    scopus 로고
    • Refraction-enhanced X-ray imaging of mouse lung using synchrotron radiation source
    • N. Yagi, Y. Suzuki, K. Umetani, Y. Kohmura, and K. Yamasaki, "Refraction-enhanced X-ray imaging of mouse lung using synchrotron radiation source," Med. Phys., 26(10), 2190-2193 (1999).
    • (1999) Med. Phys. , vol.26 , Issue.10 , pp. 2190-2193
    • Yagi, N.1    Suzuki, Y.2    Umetani, K.3    Kohmura, Y.4    Yamasaki, K.5
  • 14
    • 0038238305 scopus 로고    scopus 로고
    • X-Ray the phase contrast imaging using small focus X-ray tubes
    • in Japanese
    • C. Honda, H. Ohara, A. Ishisaka, F. Shimada, and T. Endo, "X-Ray the phase contrast imaging using small focus X-ray tubes," Japanese J. Medical Physics, 22(1), 21-29 (2002) (in Japanese).
    • (2002) Japanese J. Medical Physics , vol.22 , Issue.1 , pp. 21-29
    • Honda, C.1    Ohara, H.2    Ishisaka, A.3    Shimada, F.4    Endo, T.5
  • 15
    • 0034346182 scopus 로고    scopus 로고
    • A new method of analys is edge effect in phase contrast imaging with incoherent X-ray
    • A. Ishisaka, M. Ohara, and C. Honda, "A new method of analys is edge effect in phase contrast imaging with incoherent X-ray," Opt. Rev., 7(6), 566-572 (2000).
    • (2000) Opt. Rev. , vol.7 , Issue.6 , pp. 566-572
    • Ishisaka, A.1    Ohara, M.2    Honda, C.3
  • 17
    • 0042389484 scopus 로고    scopus 로고
    • Clinical implication of x-ray phase contrast imaging: Theoretical foundations and design considerations
    • X. Wu, and H. Liu, "Clinical implication of x-ray phase contrast imaging: Theoretical foundations and design considerations," Med. Phys., 30(8), 2169-2179 (2003).
    • (2003) Med. Phys. , vol.30 , Issue.8 , pp. 2169-2179
    • Wu, X.1    Liu, H.2
  • 20
    • 0035989954 scopus 로고    scopus 로고
    • Quantification of the effect of kVp of edge-enhancement index in phase-contrast radiography
    • E. F. Donnelly and R. R. Price, "Quantification of the effect of kVp of edge-enhancement index in phase-contrast radiography," Med. Phys. (6), 999-1002 (2002).
    • (2002) Med. Phys. , Issue.6 , pp. 999-1002
    • Donnelly, E.F.1    Price, R.R.2
  • 21
    • 0017331148 scopus 로고
    • Noise reduction by radiographic magnification
    • K. Doi and H. Imhof, "Noise reduction by radiographic magnification," Radiology, 122, 479-487 (1977).
    • (1977) Radiology , vol.122 , pp. 479-487
    • Doi, K.1    Imhof, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.