Volumn 4682, Issue , 2002, Pages 713-723

Image quality in digital phase contrast imaging using a tungsten anode X-ray tube with a small focal spot size

Author keywords

Digital imaging; Edge effect; Image quality; Magnification; Phase contrast imaging; Scatter X ray; Small focal spot size

Indexed keywords

ANODES; COMPUTER SIMULATION; IMAGE QUALITY; SYNCHROTRON RADIATION; TUNGSTEN; X RAY RADIOGRAPHY; X RAY SCATTERING; X RAY TUBES;

EID: 0036033437     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.465619     Document Type: Conference Paper
Times cited : (13)

References (10)
  • 1
    • 0002520458 scopus 로고    scopus 로고
    • Phase-sensitive X-ray imaging
    • July, 23-26
    • R. Fitzgerald, "Phase-sensitive X-ray imaging," Phys. Today July, 23-26, 2000.
    • (2000) Phys. Today
    • Fitzgerald, R.1
  • 2
    • 0032703734 scopus 로고    scopus 로고
    • Refraction-enhanced X-ray imaging of mouse lung using synchrotron radiation source
    • N. Yagi, Y. Suzuki, K. Umetani, Y. Kohmura, and K. Yamasaki, "Refraction-enhanced X-ray imaging of mouse lung using synchrotron radiation source," Med. Phys. 26, 2190-2193, 1999.
    • (1999) Med. Phys. , vol.26 , pp. 2190-2193
    • Yagi, N.1    Suzuki, Y.2    Umetani, K.3    Kohmura, Y.4    Yamasaki, K.5
  • 3
    • 0029955942 scopus 로고    scopus 로고
    • Phase-contrast imaging using polychromatic hard X-rays
    • S.W. Wilkins, T.E. Gureyev, D. Gao, A. Pogany, and A.W. Stevens, "Phase-contrast imaging using polychromatic hard X-rays," Nature 384, 335-338, 1996.
    • (1996) Nature , vol.384 , pp. 335-338
    • Wilkins, S.W.1    Gureyev, T.E.2    Gao, D.3    Pogany, A.4    Stevens, A.W.5
  • 4
    • 0005153245 scopus 로고    scopus 로고
    • Phase contrast imaging using small focus X-ray sources
    • A. Ishisaka, H. Ohara, C. Honda, F. Shimada, and T. Eado, "Phase Contrast Imaging Using Small Focus X-ray Sources," Radiology 217(P), 314, 2000.
    • (2000) Radiology , vol.217 , Issue.P , pp. 314
    • Ishisaka, A.1    Ohara, H.2    Honda, C.3    Shimada, F.4    Eado, T.5
  • 5
    • 0005153913 scopus 로고    scopus 로고
    • Phase contrast mammography using a prcatical Mo tube
    • H. Ohara, A. Ishisaka, C. Honda, F. Shimada, and T. Endo, "Phase Contrast Mammography using a Prcatical Mo Tube," Radiology, 217(P), 165, 2000.
    • (2000) Radiology , vol.217 , Issue.P , pp. 165
    • Ohara, H.1    Ishisaka, A.2    Honda, C.3    Shimada, F.4    Endo, T.5
  • 6
    • 0034346182 scopus 로고    scopus 로고
    • A new method of analyzing edge effect in phase contrast imaging with incoherent X-ray
    • A. Ishisaka, H. Ohara, and C. Honda, "A new method of analyzing edge effect in phase contrast imaging with incoherent X-ray," Optical Review 7, 566-572, 2000.
    • (2000) Optical Review , vol.7 , pp. 566-572
    • Ishisaka, A.1    Ohara, H.2    Honda, C.3
  • 8
    • 0005153246 scopus 로고
    • Image structure
    • T.H. James ed., Macmillan Publishing Press, New York
    • M.A. Kriss, Image Structure. In: T.H. James ed. The Theory of the Photographic Process. 4th ed., pp. 609-613, Macmillan Publishing Press, New York, 1977.
    • (1977) The Theory of the Photographic Process. 4th ed. , pp. 609-613
    • Kriss, M.A.1
  • 9
    • 0017331148 scopus 로고
    • Noise reduction by radiographic magnification
    • K. Doi, and H. Imhof, "Noise Reduction by Radiographic Magnification," Radiation Physics, pp. 479-487, 1977.
    • (1977) Radiation Physics , pp. 479-487
    • Doi, K.1    Imhof, H.2