메뉴 건너뛰기




Volumn 32, Issue 8, 2005, Pages 2455-2463

Dose distribution from x-ray microbeam arrays applied to radiation therapy: An EGS4 Monte Carlo study

Author keywords

EGS4; Microbeam radiation therapy; Monte Carlo simulation; Photon electron transport; X ray microdosimetry

Indexed keywords

ELECTRON TRANSPORT PROPERTIES; METALS; MOS DEVICES; NUCLEAR INSTRUMENTATION; OXIDE SEMICONDUCTORS; PHANTOMS; PHOTONS; POLARIZATION; RADIOTHERAPY; X RAYS;

EID: 23944458537     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1951043     Document Type: Article
Times cited : (46)

References (31)
  • 1
    • 0029068507 scopus 로고
    • Subacute neuropathological effects on rats of microplanar beams of x-rays from a synchrotron wiggler
    • D. N. Slatkin, P. O. Spanne, F. A. Dilmanian, J. O. Gebbers, and J. A. Laissue, "Subacute neuropathological effects on rats of microplanar beams of x-rays from a synchrotron wiggler," Proc. Natl. Acad. Sci. U.S.A. 92, 8783-8787 (1995).
    • (1995) Proc. Natl. Acad. Sci. U.S.A. , vol.92 , pp. 8783-8787
    • Slatkin, D.N.1    Spanne, P.O.2    Dilmanian, F.A.3    Gebbers, J.O.4    Laissue, J.A.5
  • 8
    • 0041302189 scopus 로고    scopus 로고
    • Response of rat skin to high-dose unidirectional x-ray microbeams: An histological study
    • N. Zhong, G. M. Morris, T. Bacarian, E. M. Rosen, and F. A. Dilmanian, "Response of rat skin to high-dose unidirectional x-ray microbeams: An histological study," Radiat. Res. 160, 133-142 (2003).
    • (2003) Radiat. Res. , vol.160 , pp. 133-142
    • Zhong, N.1    Morris, G.M.2    Bacarian, T.3    Rosen, E.M.4    Dilmanian, F.A.5
  • 12
    • 0033795170 scopus 로고    scopus 로고
    • Monte Carlo simulation of dose distributions from a synchrotron-produced microplanar beam array using the EGS4 code system
    • I. Orion, A. B. Rosenfeld, F. A. Dilmanian, F. Telang, B. Ren, and Y. Naraito, "Monte Carlo simulation of dose distributions from a synchrotron-produced microplanar beam array using the EGS4 code system," Phys. Med. Biol. 45, 2497-2508 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 2497-2508
    • Orion, I.1    Rosenfeld, A.B.2    Dilmanian, F.A.3    Telang, F.4    Ren, B.5    Naraito, Y.6
  • 13
    • 0033867218 scopus 로고    scopus 로고
    • Physics study of microbeam radiation therapy with PSI-version of Monte Carlo code GEANT as a new computational tool
    • J. Stepanek, H. Blattmann, J. A. Laissue, N. Lyubimova, M. Di Michiel, and D. N. Slatkin, "Physics study of microbeam radiation therapy with PSI-version of Monte Carlo code GEANT as a new computational tool," Med. Phys. 27, 1664-1675 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1664-1675
    • Stepanek, J.1    Blattmann, H.2    Laissue, J.A.3    Lyubimova, N.4    Di Michiel, M.5    Slatkin, D.N.6
  • 16
    • 0023138959 scopus 로고
    • Presta: The parameter reduced electron-step transport algorithm for electron Monte Carlo transport
    • A. F. Bielajew and D. W. O. Rogers, "Presta: The parameter reduced electron-step transport algorithm for electron Monte Carlo transport," Nucl. Instrum. Methods Phys. Res. B 18, 165-181 (1987).
    • (1987) Nucl. Instrum. Methods Phys. Res. B , vol.18 , pp. 165-181
    • Bielajew, A.F.1    Rogers, D.W.O.2
  • 21
    • 0033099303 scopus 로고    scopus 로고
    • Implementation of electron-impact ionization into the EGS4 code
    • Y. Namito and H. Hirayama, "Implementation of electron-impact ionization into the EGS4 code," Nucl. Instrum. Methods Phys. Res. A 423, 238-246 (1999).
    • (1999) Nucl. Instrum. Methods Phys. Res. A , vol.423 , pp. 238-246
    • Namito, Y.1    Hirayama, H.2
  • 22
    • 58149413803 scopus 로고
    • Photon cross section from 1 keV to 100 MeV for elements Z=1 to Z=100
    • E. Storm and H. I. Israel, "Photon cross section from 1 keV to 100 MeV for elements Z=1 to Z=100," Nucl. Data Tables A7, 565-681 (1970).
    • (1970) Nucl. Data Tables A , vol.7 , pp. 565-681
    • Storm, E.1    Israel, H.I.2
  • 26
    • 0026244076 scopus 로고
    • Small-angle scattering studies of disordered, porous and fractal systems
    • P. W. Schmidt, "Small-angle scattering studies of disordered, porous and fractal systems," J. Appl. Crystallogr. 24, 414-435 (1991).
    • (1991) J. Appl. Crystallogr. , vol.24 , pp. 414-435
    • Schmidt, P.W.1
  • 28
    • 0035720596 scopus 로고    scopus 로고
    • Feasibility study of online high-spatial-resolution MOSFET dosimetry in static and pulsed x-ray radiation fields
    • A. Rosenfeld, M. Lerch, T. Kron, E. Brauer-Krisch, A. Bravin, and A. Holmes-Siedle, "Feasibility study of online high-spatial-resolution MOSFET dosimetry in static and pulsed x-ray radiation fields," IEEE Trans. Nucl. Sci. 48, 2061-2068 (2001).
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 2061-2068
    • Rosenfeld, A.1    Lerch, M.2    Kron, T.3    Brauer-Krisch, E.4    Bravin, A.5    Holmes-Siedle, A.6
  • 29
    • 0027255748 scopus 로고
    • How accurately can EGS4/PRESTA calculate ion-chamber response?
    • D. W. O. Rogers, "How accurately can EGS4/PRESTA calculate ion-chamber response?," Med. Phys. 20, 319-323 (1992).
    • (1992) Med. Phys. , vol.20 , pp. 319-323
    • Rogers, D.W.O.1
  • 30
    • 85027222726 scopus 로고    scopus 로고
    • Updating of x-ray coherent scattering cross sections and their effects in microbeam and material analysis applications
    • in press
    • A. Tartari, A. Taibi, C. Bonifazzi, and M. De Felici, "Updating of x-ray coherent scattering cross sections and their effects in microbeam and material analysis applications," X-Ray Spectrom. (in press).
    • X-Ray Spectrom.
    • Tartari, A.1    Taibi, A.2    Bonifazzi, C.3    De Felici, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.